Ideal for preventative maintenance applications, this 5 kV insulation tester kit evaluates trends and eliminates doubts by improving worker safety and saving valuable time while conducting tests. In addition, this kit comes with an insulation tester, connector, heavy-duty alligator clip leads, an IP67 hard carrying case, and more.
Ideal for preventative maintenance applications, this 5 kV insulation tester kit evaluates trends and eliminates doubts by improving worker safety and saving valuable time while conducting tests. In addition, this kit comes with an insulation tester, connector, heavy-duty alligator clip leads, an IP67 hard carrying case, and more.
Conduct the entire range of test voltages specified in IEEE 43-2000 with a best-in-class CAT IV 600 V safety rating with this insulation resistance tester. With measurement storage, a PC interface, and the ability to store, share and analyze measurements through Fluke Connect, it is the perfect tool for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.
Features
Insulation testing with Fluke Connect
This insulation tester uses the ir3000 FC Connector to transmit results to Fluke Connect software. With Fluke Connect, real-time trending gives you easy-to-see visual cues, rather than rapidly changing, hard-to-read values. The ramp test shown would be difficult to interpret if you were only looking at the display on the tester. But by using Fluke Connect, you can easily see:
This single display on your smart phone or tablet gives you more information, in less time, than was previously available with just the instrument display.
Applications
Electrical Specifications | The tester's accuracy is specified for one year after calibration at operating temperatures of 0 to 35°C For operating temperatures outside the range (-20 to 0°C and 35 to 50°C), add ±0.25% per °C, except on the 20% bands add ±1% per °C |
Insulation Resistance Measurement | |
250 V | Range: <250 kΩ 250 kΩ to 5 GΩ 5 to 50 GΩ >50 GΩ Accuracy (± reading): Unspecified 5% 20% Unspecified |
500 V | Range: <500 kΩ 500 kΩ to 10 GΩ 10 to 100 GΩ >100 GΩ Accuracy (± reading): Unspecified 5% 20% Unspecified |
1000 V | Range: <1 MΩ 1 MΩ to 20 GΩ 20 to 200 GΩ >200 GΩ Accuracy (± reading): Unspecified 5% 20% Unspecified |
2500 V | Range: <2.5 MΩ 2.5 MΩ to 50 GΩ 50 to 500 GΩ >500 GΩ Accuracy (± reading): Unspecified 5% 20% Unspecified |
5000 V | Range: <5 MΩ 5 MΩ to 100 GΩ 100 GΩ to 1 TΩ >1 TΩ Accuracy (± reading): Unspecified 5% 20% Unspecified |
Bar Graph Range | 0 to 1 TΩ |
Insulation Test Voltage Accuracy | -0%, +10% at 1 mA load current |
Induced AC Mains Current Rejection | 2 mA maximum |
Capacitive Load | Charging rate: 5 seconds per µF Discharge rate: 1.5 seconds per µF |
Leakage Current Measurement | Range: 1 nA to 2 mA Accuracy: ±(5% + 2 nA) |
Capacitance Measurement | Range: 0.01 to 15 µF Accuracy: ±(15% rdg + 0.03 µF) |
Timer | Range: 0 to 99 minutes Resolution setting: 1 minute Resolution indication: 1 second |
Live Circuit Warning | Warning range: 30 to 660 V AC/DC, 50/60 Hz Voltage accuracy: ±(15% + 2 V) |
General Specifications | |
Software | FlukeView Forms™ basic software requires a PC running Windows XP, Vista, 7, or 8 |
Display | 2.9 x 4" (75 x 105 mm) |
Power | 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 Charger input (AC): 85 to 250 V AC 50/60 Hz 20 VA |
Environmental | Operating temperature: -4 to 122°F (-20 to 50°C) Storage temperature: -4 to 149°F (-20 to 65°C) Humidity: 80% to 31°C decreasing linearly to 50% at 50°C Altitude: 6561.68' (2000 m) Enclosure sealing: IP40 |
Input Overload Protection | 1000 V AC |
EMC | EN 61326 |
Safety Compliance | IEC 61010-1: Overvoltage category II, Pollution Degree 2 IEC 61010-2-030: Measurement 600 V CAT IV/1000 V CAT III IEC 61557-1, IEC 61557-2 |
Dimensions | 10.6 x 10.9 x 6.3" (269 x 277 x 160 mm) |
Weight | 8.2 lbs (3.7 kg) |
Two in one tools | Stand-alone tools | |||||
---|---|---|---|---|---|---|
Insulation test features | 1587 FC | 1577 | 1503 | 1507 | 1550C | 1555 |
Test voltages | 50 V, 100 V, 250 V, 500 V, 1000 V | 500 V, 1000 V | 500 V, 1000 V | 50 V, 100 V, 250 V, 500 V, 1000 V | 250 V to 5000 V | 250 V to 10,000 V |
Insulation resistance range | 0.01 MΩ to 2 GΩ | 0.01 MΩ to 600 GΩ | 0.01 MΩ to 2000 GΩ | 0.01 MΩ to 10 GΩ | 250 kΩ to 1 TΩ | 250 kΩ to 2 TΩ |
PI/DAR | ||||||
Auto discharge | ||||||
Timed ramp test (Breakdown) | ||||||
Pass/fail comparison | ||||||
Est. # of IRT tests | 1000 | 1000 | 2000 | 2000 | Various | Various |
Voltage > 30 V warning | ||||||
Memory | With Fluke Connect App | |||||
Remote test probe | ||||||
Lo ohms/earth-bond continuity | 200 mA source (10 mΩ resolution) | 200 mA source (10 mΩ resolution) | ||||
Display | Digital LCD | Digital LCD | Digital LCD | Digital LCD | Digital LCD/ analog display | Digital LCD/ analog display |
Hold/lock | ||||||
Multimeter features | ||||||
AC/DC volts | Note: Not all product features and specifications are listed in this table. For more complete information, see individual product data sheets. Footnotes: |
|||||
Current | ||||||
Resistance | ||||||
Continuity beeper | ||||||
Temperature (contact) | ||||||
Lo-pass filter2 | ||||||
Capacitance | ||||||
Diode test | ||||||
Frequency | ||||||
MIN/MAX | ||||||
Other features | ||||||
Backlight | ||||||
Software | Fluke Connect compatible | FlukeView® Forms Basic | Fluke View® Forms Basic | |||
Battery | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | Rechargeable | Rechargeable |
Click on a category to view a selection of compatible accessories with the Fluke 1550C FC KIT Insulation Resistance Tester Kit with connector, 5 kV, 1 TΩ.
Electrical Specifications | The tester's accuracy is specified for one year after calibration at operating temperatures of 0 to 35°C For operating temperatures outside the range (-20 to 0°C and 35 to 50°C), add ±0.25% per °C, except on the 20% bands add ±1% per °C |
Insulation Resistance Measurement | |
250 V | Range: <250 kΩ 250 kΩ to 5 GΩ 5 to 50 GΩ >50 GΩ Accuracy (± reading): Unspecified 5% 20% Unspecified |
500 V | Range: <500 kΩ 500 kΩ to 10 GΩ 10 to 100 GΩ >100 GΩ Accuracy (± reading): Unspecified 5% 20% Unspecified |
1000 V | Range: <1 MΩ 1 MΩ to 20 GΩ 20 to 200 GΩ >200 GΩ Accuracy (± reading): Unspecified 5% 20% Unspecified |
2500 V | Range: <2.5 MΩ 2.5 MΩ to 50 GΩ 50 to 500 GΩ >500 GΩ Accuracy (± reading): Unspecified 5% 20% Unspecified |
5000 V | Range: <5 MΩ 5 MΩ to 100 GΩ 100 GΩ to 1 TΩ >1 TΩ Accuracy (± reading): Unspecified 5% 20% Unspecified |
Bar Graph Range | 0 to 1 TΩ |
Insulation Test Voltage Accuracy | -0%, +10% at 1 mA load current |
Induced AC Mains Current Rejection | 2 mA maximum |
Capacitive Load | Charging rate: 5 seconds per µF Discharge rate: 1.5 seconds per µF |
Leakage Current Measurement | Range: 1 nA to 2 mA Accuracy: ±(5% + 2 nA) |
Capacitance Measurement | Range: 0.01 to 15 µF Accuracy: ±(15% rdg + 0.03 µF) |
Timer | Range: 0 to 99 minutes Resolution setting: 1 minute Resolution indication: 1 second |
Live Circuit Warning | Warning range: 30 to 660 V AC/DC, 50/60 Hz Voltage accuracy: ±(15% + 2 V) |
General Specifications | |
Software | FlukeView Forms™ basic software requires a PC running Windows XP, Vista, 7, or 8 |
Display | 2.9 x 4" (75 x 105 mm) |
Power | 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 Charger input (AC): 85 to 250 V AC 50/60 Hz 20 VA |
Environmental | Operating temperature: -4 to 122°F (-20 to 50°C) Storage temperature: -4 to 149°F (-20 to 65°C) Humidity: 80% to 31°C decreasing linearly to 50% at 50°C Altitude: 6561.68' (2000 m) Enclosure sealing: IP40 |
Input Overload Protection | 1000 V AC |
EMC | EN 61326 |
Safety Compliance | IEC 61010-1: Overvoltage category II, Pollution Degree 2 IEC 61010-2-030: Measurement 600 V CAT IV/1000 V CAT III IEC 61557-1, IEC 61557-2 |
Dimensions | 10.6 x 10.9 x 6.3" (269 x 277 x 160 mm) |
Weight | 8.2 lbs (3.7 kg) |
Two in one tools | Stand-alone tools | |||||
---|---|---|---|---|---|---|
Insulation test features | 1587 FC | 1577 | 1503 | 1507 | 1550C | 1555 |
Test voltages | 50 V, 100 V, 250 V, 500 V, 1000 V | 500 V, 1000 V | 500 V, 1000 V | 50 V, 100 V, 250 V, 500 V, 1000 V | 250 V to 5000 V | 250 V to 10,000 V |
Insulation resistance range | 0.01 MΩ to 2 GΩ | 0.01 MΩ to 600 GΩ | 0.01 MΩ to 2000 GΩ | 0.01 MΩ to 10 GΩ | 250 kΩ to 1 TΩ | 250 kΩ to 2 TΩ |
PI/DAR | ||||||
Auto discharge | ||||||
Timed ramp test (Breakdown) | ||||||
Pass/fail comparison | ||||||
Est. # of IRT tests | 1000 | 1000 | 2000 | 2000 | Various | Various |
Voltage > 30 V warning | ||||||
Memory | With Fluke Connect App | |||||
Remote test probe | ||||||
Lo ohms/earth-bond continuity | 200 mA source (10 mΩ resolution) | 200 mA source (10 mΩ resolution) | ||||
Display | Digital LCD | Digital LCD | Digital LCD | Digital LCD | Digital LCD/ analog display | Digital LCD/ analog display |
Hold/lock | ||||||
Multimeter features | ||||||
AC/DC volts | Note: Not all product features and specifications are listed in this table. For more complete information, see individual product data sheets. Footnotes: |
|||||
Current | ||||||
Resistance | ||||||
Continuity beeper | ||||||
Temperature (contact) | ||||||
Lo-pass filter2 | ||||||
Capacitance | ||||||
Diode test | ||||||
Frequency | ||||||
MIN/MAX | ||||||
Other features | ||||||
Backlight | ||||||
Software | Fluke Connect compatible | FlukeView® Forms Basic | Fluke View® Forms Basic | |||
Battery | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | Rechargeable | Rechargeable |