Compact and handheld, this rugged insulation multimeter features maximum versatility for both troubleshooting and preventative maintenance. Ideally suited for work on motors, generators, cables, or switchgear, this multimeter also features True RMS capabilities, a large backlit LCD, and an auto power-off to save battery power.
Compact and handheld, this rugged insulation multimeter features maximum versatility for both troubleshooting and preventative maintenance. Ideally suited for work on motors, generators, cables, or switchgear, this multimeter also features True RMS capabilities, a large backlit LCD, and an auto power-off to save battery power.
Features
Applications
Disconnect any electronic devices like motor drives, PLC’s, transmitters, etc. before performing insulation testing. Electronics can be damaged by applying higher than normal voltage.
The effect of temperature should be considered - it is recommended that tests be performed at a standard conductor temperature of 20 °C (68 °F) or that a temperature baseline is established while compensating future readings by using a DMM with a probe or an infrared thermometer.
Select a test voltage appropriate for the insulation being tested. The objective is to stress the insulation but not to over-stress it. When in doubt, use a lower test voltage. It’s usually appropriate to test insulation at twice the voltage it normally sees: for example 460 V to 600 V rated equipment is often tested at 1000 V.
When using an insulation tester, leave the leads connected when you stop the test. The insulation tester can discharge any residual test voltage.
Conductors that are close to each other have a normal capacitance. This will cause an insulation resistance reading to start low and increase steadily until it stabilizes. This type of increase is normal, but if the reading jumps violently down and up again this indicates arcing.
Although the current is tightly limited, an insulation tester can generate sparks and minor but painful burns. The unexpected surprise can cause an operator to jerk away. As always, work away from live systems and use safe work practices when working overhead.
Facilities maintenance professionals face a wide range of challenges, from electrical and mechanical equipment uptime to overall safety concerns. It’s critical to maintain facilities and the associated assets at peak performance. Let's review the issues faced by maintenance managers, IT support, and electrical/mechanical technicians. Along with the Fluke solutions that offer to save you time and money while increasing efficiency and safety. Fluke makes reliable, rugged and accurate tools to maintain electromechanical systems, motors, pumps, electrical distribution systems and more to keep your world up and running.
Learn MoreVoltage DC | |
Maximum Voltage | 1000 V |
Accuracy | ±(0.2% + 2) |
Maximum Resolution | 0.001 V |
Voltage AC | |
Maximum Voltage | 1000 V |
Accuracy | ±(2% + 3) |
Maximum Resolution | 0.1 mV |
Current DC | |
Maximum Amps | 400 mA |
Amps Accuracy | ±(1.0% + 2) |
Maximum Resolution | 0.01 mA |
Current AC | |
Maximum Amps | 400 mA |
Amps Accuracy | ±(2.0% + 2) |
Maximum Resolution | 0.01 mA |
Resistance | |
Maximum Resistance | 50 MΩ |
Accuracy | ±(1.2% + 2) |
Maximum Resolution | 0.1 Ω |
Insulation Test | |
Minimum Test Current at 1 kΩ/V | 1 mA |
Test Voltages | 500, 1000 V |
Maximum Resistance per Test Voltage | 50 V 100 V 250 V 500 V 1000 V: 600 MΩ |
Maximum Resolution per Test Voltage | 50 V: 0.01 MΩ 100 V: 0.01 MΩ 250 V: 0.1 MΩ 500 V: 0.1 MΩ 1000 V: 0.1 MΩ |
Accuracy per Test Voltage | 50 V: ±(3% + 5) 100 V: ±(3% + 5) 250 V: ±(1.5% + 5) 500 V: ±(2.0% + 5) 1000 V: ±(2.0% + 5) |
Environmental Specifications | |
Operating Temperature | -4 to 131°F (–20 to 55°C) |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Humidity (Without Condensation) | 0 to 95%: 50 to 86°F (10 to 30°C) 0 to 75%: 86 to 104°F (30 to 40°C) 0 to 40%: 104 to 131°F (40 to 55°C) |
Operating Altitude | 6561.68' (2000 m) |
Mechanical and General Specifications | |
Battery Life Alkaline | Meter use: 1000 hours Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off |
Dimensions | 7.99 x 3.94 x 1.97" (203 x 100 x 50 mm) (with holster) |
Weight | 22 oz (624 g) |
IP Rating | IP40 |
Safety Specifications | |
Overvoltage Category | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
Agency Approvals | 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
Click on a category to view a selection of compatible accessories with the Fluke 1577 Insulation Multimeter, 1000 V.
Voltage DC | |
Maximum Voltage | 1000 V |
Accuracy | ±(0.2% + 2) |
Maximum Resolution | 0.001 V |
Voltage AC | |
Maximum Voltage | 1000 V |
Accuracy | ±(2% + 3) |
Maximum Resolution | 0.1 mV |
Current DC | |
Maximum Amps | 400 mA |
Amps Accuracy | ±(1.0% + 2) |
Maximum Resolution | 0.01 mA |
Current AC | |
Maximum Amps | 400 mA |
Amps Accuracy | ±(2.0% + 2) |
Maximum Resolution | 0.01 mA |
Resistance | |
Maximum Resistance | 50 MΩ |
Accuracy | ±(1.2% + 2) |
Maximum Resolution | 0.1 Ω |
Insulation Test | |
Minimum Test Current at 1 kΩ/V | 1 mA |
Test Voltages | 500, 1000 V |
Maximum Resistance per Test Voltage | 50 V 100 V 250 V 500 V 1000 V: 600 MΩ |
Maximum Resolution per Test Voltage | 50 V: 0.01 MΩ 100 V: 0.01 MΩ 250 V: 0.1 MΩ 500 V: 0.1 MΩ 1000 V: 0.1 MΩ |
Accuracy per Test Voltage | 50 V: ±(3% + 5) 100 V: ±(3% + 5) 250 V: ±(1.5% + 5) 500 V: ±(2.0% + 5) 1000 V: ±(2.0% + 5) |
Environmental Specifications | |
Operating Temperature | -4 to 131°F (–20 to 55°C) |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Humidity (Without Condensation) | 0 to 95%: 50 to 86°F (10 to 30°C) 0 to 75%: 86 to 104°F (30 to 40°C) 0 to 40%: 104 to 131°F (40 to 55°C) |
Operating Altitude | 6561.68' (2000 m) |
Mechanical and General Specifications | |
Battery Life Alkaline | Meter use: 1000 hours Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off |
Dimensions | 7.99 x 3.94 x 1.97" (203 x 100 x 50 mm) (with holster) |
Weight | 22 oz (624 g) |
IP Rating | IP40 |
Safety Specifications | |
Overvoltage Category | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
Agency Approvals | 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
Click on a category to view a selection of compatible accessories with the Fluke 1577 Insulation Multimeter, 1000 V.