Fluke 1555 FC Insulation Resistance Tester with connector, 10 kV, 2 TΩ

Model: FLUKE-1555 FC | Order No: 1555FC | UPC: 095969868891

Fluke 1555 FC Insulation Resistance Tester with connector, 10 kV, 2 TΩ

Model: FLUKE-1555 FC | Order No: 1555FC | UPC: 095969868891

Ideal for preventative maintenance applications, this 10 kV insulation tester evaluates trends and eliminates doubts by improving worker safety and saving valuable time while conducting tests. In addition, this insulation tester features a CAT III 1000 V/CAT IV 600 V safety rating and comes with a wireless connector for remote operation.

Ideal for preventative maintenance applications, this 10 kV insulation tester evaluates trends and eliminates doubts by improving worker safety and saving valuable time while conducting tests. In addition, this insulation tester features a CAT III 1000 V/CAT IV 600 V safety rating and comes with a wireless connector for remote operation.

Your Price $7070.99 USD
Availability 2 to 3 Weeks
Quantity

Traceable In-House Calibration Certificate for your FLUKE-1555 FC Fluke 1555 FC Insulation Resistance Tester with connector

Traceable In-House Calibration Certificate for your FLUKE-1555 FC Fluke 1555 FC Insulation Resistance Tester with connector

Recommended Accessories


Fluke FLUKE-1555 FC Offers

Conduct the entire range of test voltages specified in IEEE 43-2000 with a best-in-class CAT IV 600 V safety rating with this insulation resistance tester. With measurement storage, a PC interface, and the ability to store, share and analyze measurements through Fluke Connect, it is the perfect tool for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.

Features

  • Increase your confidence and safety level - Wireless start/stop capability keeps you out of harm's way during actual tests
  • Know if a line voltage is present before starting a test - A warning function alerts the user that the line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
  • Turn changing digital readouts into a meaningful visual output - PI/DAR timed ratio tests with TrendIt™ graphs help identify the moisture and contaminated insulation problems faster
  • Improve the accuracy of your data for preventative maintenance programs - Temperature compensation through Fluke Connect app for establishing accurate baselines and relevant historical comparisons
  • Select test voltages up to 10 kV
  • CAT III 1000 V, CAT IV 600 V safety rating
  • Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
  • Reduce paperwork while creating an auditable data trail by wirelessly storing results in Fluke Connect
  • Long battery life gives the user over 750 tests between charges
  • Guard system eliminates the effect of surface leakage current on high-resistance measurements
  • Historical tracking and trending of assets identify degradation over time, allows real-time decisions to be made in the field with Fluke Connect Assets (sold separately)
  • Large digital/analog LCD for easy viewing
  • Capacitance and leakage current measurement
  • Ramp function for breakdown testing
  • Resistance measurements up to 2 TΩ
  • Timer settings up to 99 minutes for timed tests

Insulation testing with Fluke Connect

This insulation tester uses the ir3000 FC Connector to transmit results to Fluke Connect software. With Fluke Connect, real-time trending gives you easy-to-see visual cues, rather than rapidly changing, hard-to-read values. The ramp test shown would be difficult to interpret if you were only looking at the display on the tester. But by using Fluke Connect, you can easily see:

  • A ramp test has been chosen during setup;
  • An ending test voltage of 2500 V was chosen;
  • The test has run for 28 seconds so far;
  • The instantaneous resistance measurement is 998.4 GΩ;
  • The test voltage has been ramping upwards;
  • During that time, the measured resistance has been increasing slowly. If the resistance drops off, this would suggest poor insulation health or moisture content. With a sudden drop in resistance, this tester will cut the voltage and display the ramped voltage and resistance.

This single display on your smart phone or tablet gives you more information, in less time, than was previously available with just the instrument display.

Applications

  • Preventative maintenance
  • Predictive maintenance
  • Commissioning
  • Troubleshooting

Fluke FLUKE-1555 FC Specifications

Electrical Specifications The tester's accuracy is specified for one year after calibration at operating temperatures of 0 to 35°C
For operating temperatures outside the range (-20 to 0°C and 35 to 50°C), add ±0.25% per °C, except on the 20% bands add ±1% per °C
Insulation Resistance Measurement
250 V Range:
<250 kΩ
250 kΩ to 5 GΩ
5 to 50 GΩ
>50 GΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
500 V Range:
<500 kΩ
500 kΩ to 10 GΩ
10 to 100 GΩ
>100 GΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
1000 V Range:
<1 MΩ
1 MΩ to 20 GΩ
20 to 200 GΩ
>200 GΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
2500 V Range:
<2.5 MΩ
2.5 MΩ to 50 GΩ
50 to 500 GΩ
>500 GΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
5000 V Range:
<5 MΩ
5 MΩ to 100 GΩ
100 GΩ to 1 TΩ
>1 TΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
10,000 V Range:
<10 MΩ
10 MΩ to 200 GΩ
200 GΩ to 2 TΩ
>2 TΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
Bar Graph Range 0 to 1 TΩ
Insulation Test Voltage Accuracy -0%, +10% at 1 mA load current
Induced AC Mains Current Rejection 2 mA maximum
Capacitive Load Charging rate: 5 seconds per µF
Discharge rate: 1.5 seconds per µF
Leakage Current Measurement Range: 1 nA to 2 mA
Accuracy: ±(5% + 2 nA)
Capacitance Measurement Range: 0.01 to 15 µF
Accuracy: ±(15% rdg + 0.03 µF)
Timer Range: 0 to 99 minutes
Resolution setting: 1 minute
Resolution indication: 1 second
Live Circuit Warning Warning range: 30 to 660 V AC/DC, 50/60 Hz
Voltage accuracy: ±(15% + 2 V)
General Specifications
Software FlukeView Forms™ basic software requires a PC running Windows XP, Vista, 7, or 8
Display 2.9 x 4" (75 x 105 mm)
Power 12 V lead-acid rechargeable battery, Yuasa NP2.8-12
Charger input (AC): 85 to 250 V AC 50/60 Hz 20 VA
Environmental Operating temperature: -4 to 122°F (-20 to 50°C)
Storage temperature: -4 to 149°F (-20 to 65°C)
Humidity: 80% to 31°C decreasing linearly to 50% at 50°C
Altitude: 6561.68' (2000 m)
Enclosure sealing: IP40
Input Overload Protection 1000 V AC
EMC EN 61326
Safety Compliance IEC 61010-1: Overvoltage category II, Pollution Degree 2
IEC 61010-2-030: Measurement 600 V CAT IV/1000 V CAT III
IEC 61557-1, IEC 61557-2
Dimensions 10.6 x 10.9 x 6.3" (269 x 277 x 160 mm)
Weight 8.2 lbs (3.7 kg)
Click here for complete specifications on the Fluke FLUKE-1555 FC

What's included with the Fluke FLUKE-1555 FC

  • Insulation Resistance Tester
  • FC Connector
  • Test Cables with Alligator Clips (Red, Black, Green)
  • Heavy Duty Alligator Clip Leads
  • Infrared Adapter with Interface Cable
  • Soft Carrying Case
  • AC Power Cord
  • Quick Reference Card
  • USB-IR Cable Installation Guide
  • Three-Year Warranty

Webinar: Solar Trends and Troubleshooting PV Systems with Fluke


In recent years, more and more people are opting for greener solutions to minimize environmental damage, which has led to an increased demand for environmentally safe solutions. As such, there are more efforts being made on using solar energy in various segments of our society. These changes also entail the need for tools that improve testing and troubleshooting solar solutions.
Fluke 1587 FC Insulation Multimeter Fluke 1577 Insulation Multimeter Fluke 1503 Insulation Resistance Meter Fluke 1507 Insulation Resistance Tester Fluke 1550C Insulation Resistance Tester Fluke 1555 Insulation Resistance Tester
Two in one tools Stand-alone tools
Insulation test features 1587 FC 1577 1503 1507 1550C 1555
Test voltages 50 V, 100 V, 250 V, 500 V, 1000 V 500 V, 1000 V 500 V, 1000 V 50 V, 100 V, 250 V, 500 V, 1000 V 250 V to 5000 V 250 V to 10,000 V
Insulation resistance range 0.01 MΩ to 2 GΩ 0.01 MΩ to 600 GΩ 0.01 MΩ to 2000 GΩ 0.01 MΩ to 10 GΩ 250 kΩ to 1 TΩ 250 kΩ to 2 TΩ
PI/DAR
Auto discharge
Timed ramp test (Breakdown)
Pass/fail comparison
Est. # of IRT tests 1000 1000 2000 2000 Various Various
Voltage > 30 V warning
Memory With Fluke Connect App
Remote test probe
Lo ohms/earth-bond continuity 200 mA source (10 mΩ resolution) 200 mA source (10 mΩ resolution)
Display Digital LCD Digital LCD Digital LCD Digital LCD Digital LCD/ analog display Digital LCD/ analog display
Hold/lock
Multimeter features
AC/DC volts

Note: Not all product features and specifications are listed in this table. For more complete information, see individual product data sheets.

Footnotes:
1. Function useful for checking connections and motor windings. Also useful for users who are required to perform earth-bond continuity measurements during installation testing.
2. Filter for variable-speed motor drive measurements.

Current
Resistance
Continuity beeper
Temperature (contact)
Lo-pass filter2
Capacitance
Diode test
Frequency
MIN/MAX
Other features
Backlight
Software Fluke Connect compatible FlukeView® Forms Basic Fluke View® Forms Basic
Battery 4 AA (NEDA 15A or IEC LR6) 4 AA (NEDA 15A or IEC LR6) 4 AA (NEDA 15A or IEC LR6) 4 AA (NEDA 15A or IEC LR6) Rechargeable Rechargeable
Find out more about insulation testing

Click on a category to view a selection of compatible accessories with the Fluke 1555 FC Insulation Resistance Tester with connector, 10 kV, 2 TΩ.

Ask a question about Fluke 1555 FC Insulation Resistance Tester with connector, 10 kV, 2 TΩ

Customer Reviews for the Fluke FLUKE-1555 FC

Fluke FLUKE-1555 FC Offers

Conduct the entire range of test voltages specified in IEEE 43-2000 with a best-in-class CAT IV 600 V safety rating with this insulation resistance tester. With measurement storage, a PC interface, and the ability to store, share and analyze measurements through Fluke Connect, it is the perfect tool for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.

Features

  • Increase your confidence and safety level - Wireless start/stop capability keeps you out of harm's way during actual tests
  • Know if a line voltage is present before starting a test - A warning function alerts the user that the line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
  • Turn changing digital readouts into a meaningful visual output - PI/DAR timed ratio tests with TrendIt™ graphs help identify the moisture and contaminated insulation problems faster
  • Improve the accuracy of your data for preventative maintenance programs - Temperature compensation through Fluke Connect app for establishing accurate baselines and relevant historical comparisons
  • Select test voltages up to 10 kV
  • CAT III 1000 V, CAT IV 600 V safety rating
  • Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
  • Reduce paperwork while creating an auditable data trail by wirelessly storing results in Fluke Connect
  • Long battery life gives the user over 750 tests between charges
  • Guard system eliminates the effect of surface leakage current on high-resistance measurements
  • Historical tracking and trending of assets identify degradation over time, allows real-time decisions to be made in the field with Fluke Connect Assets (sold separately)
  • Large digital/analog LCD for easy viewing
  • Capacitance and leakage current measurement
  • Ramp function for breakdown testing
  • Resistance measurements up to 2 TΩ
  • Timer settings up to 99 minutes for timed tests

Insulation testing with Fluke Connect

This insulation tester uses the ir3000 FC Connector to transmit results to Fluke Connect software. With Fluke Connect, real-time trending gives you easy-to-see visual cues, rather than rapidly changing, hard-to-read values. The ramp test shown would be difficult to interpret if you were only looking at the display on the tester. But by using Fluke Connect, you can easily see:

  • A ramp test has been chosen during setup;
  • An ending test voltage of 2500 V was chosen;
  • The test has run for 28 seconds so far;
  • The instantaneous resistance measurement is 998.4 GΩ;
  • The test voltage has been ramping upwards;
  • During that time, the measured resistance has been increasing slowly. If the resistance drops off, this would suggest poor insulation health or moisture content. With a sudden drop in resistance, this tester will cut the voltage and display the ramped voltage and resistance.

This single display on your smart phone or tablet gives you more information, in less time, than was previously available with just the instrument display.

Applications

  • Preventative maintenance
  • Predictive maintenance
  • Commissioning
  • Troubleshooting

Fluke FLUKE-1555 FC Specifications

Electrical Specifications The tester's accuracy is specified for one year after calibration at operating temperatures of 0 to 35°C
For operating temperatures outside the range (-20 to 0°C and 35 to 50°C), add ±0.25% per °C, except on the 20% bands add ±1% per °C
Insulation Resistance Measurement
250 V Range:
<250 kΩ
250 kΩ to 5 GΩ
5 to 50 GΩ
>50 GΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
500 V Range:
<500 kΩ
500 kΩ to 10 GΩ
10 to 100 GΩ
>100 GΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
1000 V Range:
<1 MΩ
1 MΩ to 20 GΩ
20 to 200 GΩ
>200 GΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
2500 V Range:
<2.5 MΩ
2.5 MΩ to 50 GΩ
50 to 500 GΩ
>500 GΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
5000 V Range:
<5 MΩ
5 MΩ to 100 GΩ
100 GΩ to 1 TΩ
>1 TΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
10,000 V Range:
<10 MΩ
10 MΩ to 200 GΩ
200 GΩ to 2 TΩ
>2 TΩ

Accuracy (± reading):
Unspecified
5%
20%
Unspecified
Bar Graph Range 0 to 1 TΩ
Insulation Test Voltage Accuracy -0%, +10% at 1 mA load current
Induced AC Mains Current Rejection 2 mA maximum
Capacitive Load Charging rate: 5 seconds per µF
Discharge rate: 1.5 seconds per µF
Leakage Current Measurement Range: 1 nA to 2 mA
Accuracy: ±(5% + 2 nA)
Capacitance Measurement Range: 0.01 to 15 µF
Accuracy: ±(15% rdg + 0.03 µF)
Timer Range: 0 to 99 minutes
Resolution setting: 1 minute
Resolution indication: 1 second
Live Circuit Warning Warning range: 30 to 660 V AC/DC, 50/60 Hz
Voltage accuracy: ±(15% + 2 V)
General Specifications
Software FlukeView Forms™ basic software requires a PC running Windows XP, Vista, 7, or 8
Display 2.9 x 4" (75 x 105 mm)
Power 12 V lead-acid rechargeable battery, Yuasa NP2.8-12
Charger input (AC): 85 to 250 V AC 50/60 Hz 20 VA
Environmental Operating temperature: -4 to 122°F (-20 to 50°C)
Storage temperature: -4 to 149°F (-20 to 65°C)
Humidity: 80% to 31°C decreasing linearly to 50% at 50°C
Altitude: 6561.68' (2000 m)
Enclosure sealing: IP40
Input Overload Protection 1000 V AC
EMC EN 61326
Safety Compliance IEC 61010-1: Overvoltage category II, Pollution Degree 2
IEC 61010-2-030: Measurement 600 V CAT IV/1000 V CAT III
IEC 61557-1, IEC 61557-2
Dimensions 10.6 x 10.9 x 6.3" (269 x 277 x 160 mm)
Weight 8.2 lbs (3.7 kg)
Click here for complete specifications on the Fluke FLUKE-1555 FC

What's included with the Fluke FLUKE-1555 FC

  • Insulation Resistance Tester
  • FC Connector
  • Test Cables with Alligator Clips (Red, Black, Green)
  • Heavy Duty Alligator Clip Leads
  • Infrared Adapter with Interface Cable
  • Soft Carrying Case
  • AC Power Cord
  • Quick Reference Card
  • USB-IR Cable Installation Guide
  • Three-Year Warranty

Webinar: Solar Trends and Troubleshooting PV Systems with Fluke


In recent years, more and more people are opting for greener solutions to minimize environmental damage, which has led to an increased demand for environmentally safe solutions. As such, there are more efforts being made on using solar energy in various segments of our society. These changes also entail the need for tools that improve testing and troubleshooting solar solutions.
Fluke 1587 FC Insulation Multimeter Fluke 1577 Insulation Multimeter Fluke 1503 Insulation Resistance Meter Fluke 1507 Insulation Resistance Tester Fluke 1550C Insulation Resistance Tester Fluke 1555 Insulation Resistance Tester
Two in one tools Stand-alone tools
Insulation test features 1587 FC 1577 1503 1507 1550C 1555
Test voltages 50 V, 100 V, 250 V, 500 V, 1000 V 500 V, 1000 V 500 V, 1000 V 50 V, 100 V, 250 V, 500 V, 1000 V 250 V to 5000 V 250 V to 10,000 V
Insulation resistance range 0.01 MΩ to 2 GΩ 0.01 MΩ to 600 GΩ 0.01 MΩ to 2000 GΩ 0.01 MΩ to 10 GΩ 250 kΩ to 1 TΩ 250 kΩ to 2 TΩ
PI/DAR
Auto discharge
Timed ramp test (Breakdown)
Pass/fail comparison
Est. # of IRT tests 1000 1000 2000 2000 Various Various
Voltage > 30 V warning
Memory With Fluke Connect App
Remote test probe
Lo ohms/earth-bond continuity 200 mA source (10 mΩ resolution) 200 mA source (10 mΩ resolution)
Display Digital LCD Digital LCD Digital LCD Digital LCD Digital LCD/ analog display Digital LCD/ analog display
Hold/lock
Multimeter features
AC/DC volts

Note: Not all product features and specifications are listed in this table. For more complete information, see individual product data sheets.

Footnotes:
1. Function useful for checking connections and motor windings. Also useful for users who are required to perform earth-bond continuity measurements during installation testing.
2. Filter for variable-speed motor drive measurements.

Current
Resistance
Continuity beeper
Temperature (contact)
Lo-pass filter2
Capacitance
Diode test
Frequency
MIN/MAX
Other features
Backlight
Software Fluke Connect compatible FlukeView® Forms Basic Fluke View® Forms Basic
Battery 4 AA (NEDA 15A or IEC LR6) 4 AA (NEDA 15A or IEC LR6) 4 AA (NEDA 15A or IEC LR6) 4 AA (NEDA 15A or IEC LR6) Rechargeable Rechargeable
Find out more about insulation testing

Click on a category to view a selection of compatible accessories with the Fluke 1555 FC Insulation Resistance Tester with connector, 10 kV, 2 TΩ.

Ask a question about Fluke 1555 FC Insulation Resistance Tester with connector, 10 kV, 2 TΩ

Customer Reviews for the Fluke FLUKE-1555 FC

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.
Calibration Lab