Ideal for troubleshooting and preventative maintenance, this insulation multimeter comes in a compact, handheld design, and features True RMS capabilities. Additionally, this tool is compatible with the Fluke Connect app, which allows the user to see and share measurement results wirelessly with their smartphone or tablet.
Ideal for troubleshooting and preventative maintenance, this insulation multimeter comes in a compact, handheld design, and features True RMS capabilities. Additionally, this tool is compatible with the Fluke Connect app, which allows the user to see and share measurement results wirelessly with their smartphone or tablet.
The high-performance 2-in-1 insulation digital multimeter
This insulation multimeter is the combination of a digital insulation tester that comes supplied with a full-featured, True RMS digital multimeter in a single compact, handheld unit, which enables maximum versatility for troubleshooting and preventative maintenance.
Features
Keep yourself safe. Find hidden problems faster. Put the paperwork down.
Fluke Connect and this insulation multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.
Add diagnostics with Fluke Connect
Fluke Connect is enabled so you can download the free application to your smartphone and gain additional functions, including:
Disconnect any electronic devices like motor drives, PLC’s, transmitters, etc. before performing insulation testing. Electronics can be damaged by applying higher than normal voltage.
The effect of temperature should be considered - it is recommended that tests be performed at a standard conductor temperature of 20 °C (68 °F) or that a temperature baseline is established while compensating future readings by using a DMM with a probe or an infrared thermometer.
Select a test voltage appropriate for the insulation being tested. The objective is to stress the insulation but not to over-stress it. When in doubt, use a lower test voltage. It’s usually appropriate to test insulation at twice the voltage it normally sees: for example 460 V to 600 V rated equipment is often tested at 1000 V.
When using an insulation tester, leave the leads connected when you stop the test. The insulation tester can discharge any residual test voltage.
Conductors that are close to each other have a normal capacitance. This will cause an insulation resistance reading to start low and increase steadily until it stabilizes. This type of increase is normal, but if the reading jumps violently down and up again this indicates arcing.
Although the current is tightly limited, an insulation tester can generate sparks and minor but painful burns. The unexpected surprise can cause an operator to jerk away. As always, work away from live systems and use safe work practices when working overhead.
Infrared cameras, also called thermal imagers, are useful for troubleshooting motor problems as well as for monitoring motor condition for preventative maintenance in power generation, manufacturing and commercial plants. Thermal images of motors reveal their operating condition as indicated by surface temperature. Such condition monitoring is important as a way to avert many unexpected motor malfunctions in systems that are critical to manufacturing. The onset of motor failures can often be detected by a variety of techniques, including vibration, ultrasound and thermal imaging.
In this article, we cover why use thermal imaging and what to scan, as well as some notes on what to look for, including shaft misalignment.
Read the ArticleAC Voltage Measurements | |
Range | 600 mV 6 V 60 V 600 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
50 to 60 Hz ±(% of Rdg + counts) | ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3) |
60 to 5000 Hz ±(% of Rdg + counts) | ±(2% + 3) ±(2% + 3) ±(2% + 3) ±(2% + 3)1 ±(2% + 3)1 |
Low-Pass Filter Voltage | |
Range | 600 mV 6 V 60 V 600 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
50 to 60 Hz ±(% of Rdg + counts) | ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3) |
60 to 400 Hz ±(% of Rdg + counts) | ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) |
DC Voltage Measurement | |
Range | 6 V DC 60 V DC 600 V DC 1000 V DC |
Resolution | 0.001 V 0.01 V 0.1 V 1 V |
Accuracy ±(% of Rdg + Counts) | ±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2) |
Input Impedance | 10 MΩ (nominal), <100 pF |
Nominal Mode Rejection Ratio | >60 dB at 50 or 60 Hz |
Common Mode Rejection Ratio | >120 dB at DC, 50 or 60 Hz (1 k unbalance) |
DC Millivolts Measurement | |
Range | 600 mV DC |
Resolution | 0.1 mV |
Accuracy ±(% of Rdg + Counts) | ±(0.1 + 1) |
DC and AC Current Measurement | |
Range | 400 mA |
Resolution | 0.1 mA |
Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)1 |
Burden Voltage (Typical) | 2 mV/mA |
Range | 60 mA |
Resolution | 0.01 mA |
Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)1 |
Burden Voltage (Typical) | 2 mV/mA |
DC | |
Range | 400 mA |
Resolution | 0.1 mA |
Accuracy ±(% of Rdg+Counts) | ±(0.2% + 2) |
Burden Voltage (Typical) | 2 mV/mA |
Range | 60 mA |
Resolution | 0.01 mA |
Accuracy ±(% of Rdg+Counts) | ±(0.2% + 2) |
Burden Voltage (Typical) | 2 mV/mA |
Overload | 600 mA for 2 minutes maximum |
Fuse Protection for mA Input | 0.44 mA, 1000 V, IR 10 kA |
AC Conversion | Inputs are ac-coupled and calibrated to the RMS value of sine wave input |
Ohms Measurement | |
Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 50 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy +(% of Rdg+Counts)1 | ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(1.5% + 3) |
Overload Protection | 1000 RMS or DC |
Open Circuit Test Voltage | <8 V DC |
Short Circuit Current | <1.1 mA |
Diode Test | |
Diode Test Indication | Display voltage drop: 0.6 V at 1.0 mA nominal test current |
Accuracy | ±(2% + 3) |
Continuity Test | |
Continuity Indication | Continuous audible tone for test resistance below 25 Ω and off above 100 Ω Maximum reading: 1000 Ω |
Open Circuit Voltage | <8.0 V |
Short Circuit Current | 1.0 mA typical |
Overload Protection | 1000 V RMS |
Response Time | >1 m sec |
Frequency Measurement | |
Range | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy ±(% of Rdg+Counts) | ±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1) |
Frequency Counter Sensitivity | |
600.0 mV AC | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 mV V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 150.0 mV DC Trigger Levels¹ to 20 kHz2: NA |
6.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 1.0 V V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 1.5 V DC Trigger Levels¹ to 20 kHz2: -400.0 mV and 2.5 V |
60.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 10.0 V V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 36.0 V DC Trigger Levels¹ to 20 kHz2: 1.2 V and 4.0 V |
600.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 V V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V |
1000.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 300.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V |
Capacitance | |
Range | 1000 nF 10.00 µF 100.0 µF 9999 µF |
Resolution | 1 nF 0.01 µF 0.1 µF 1 µF |
Accuracy ±(% of Rdg+Counts) | ±(1.2% + 2) ±(1.2% + 2) ±(1.2% ± 90 counts) ±(1.2% ± 90 counts) |
Temperature Measurement | |
Range | -40 to 998°F (-40 to 537°C) |
Resolution | 0.1°F (0.1°C) |
Accuracy ±(% of Rdg+Counts)1 | ±(1% + 10 counts) ±(1% + 18 counts) |
Insulation Specifications | |
Measurement Range | 0.01 MΩ to 2 GΩ |
Test Voltages | 50, 100, 250, 500, 1000 V |
Test Voltage Accuracy | 20%, 0% |
Short-Circuit Test Current | 1 mA nominal |
Auto Discharge | Discharge time <0.5 second for C=1 µF or less |
Live Circuit Detection | Inhibit test if terminal voltage >30 V prior to initialization of test |
Maximum Capacitive Load | Operable with up to 1 µF load |
Output Voltage | |
50 V (0% to +20%) | Display range: 0.01 to 6.00 MΩ Resolution: 0.01 MΩ Test current: 1 mA at 50 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 50.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 50 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) |
100 V (0% to +20%) | Display range: 0.01 to 6.00 MΩ Resolution: 0.01 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 100.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) |
250 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 250 MΩ Resolution: 1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) |
500 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 500 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 500 MΩ Resolution: 1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) |
1000 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 600 MΩ Resolution: 1 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 0.6 to 2.0 GΩ Resolution: 100 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts) |
Two in one tools | Stand-alone tools | |||||
---|---|---|---|---|---|---|
Insulation test features | 1587 FC | 1577 | 1503 | 1507 | 1550C | 1555 |
Test voltages | 50 V, 100 V, 250 V, 500 V, 1000 V | 500 V, 1000 V | 500 V, 1000 V | 50 V, 100 V, 250 V, 500 V, 1000 V | 250 V to 5000 V | 250 V to 10,000 V |
Insulation resistance range | 0.01 MΩ to 2 GΩ | 0.01 MΩ to 600 GΩ | 0.01 MΩ to 2000 GΩ | 0.01 MΩ to 10 GΩ | 250 kΩ to 1 TΩ | 250 kΩ to 2 TΩ |
PI/DAR | ||||||
Auto discharge | ||||||
Timed ramp test (Breakdown) | ||||||
Pass/fail comparison | ||||||
Est. # of IRT tests | 1000 | 1000 | 2000 | 2000 | Various | Various |
Voltage > 30 V warning | ||||||
Memory | With Fluke Connect App | |||||
Remote test probe | ||||||
Lo ohms/earth-bond continuity | 200 mA source (10 mΩ resolution) | 200 mA source (10 mΩ resolution) | ||||
Display | Digital LCD | Digital LCD | Digital LCD | Digital LCD | Digital LCD/ analog display | Digital LCD/ analog display |
Hold/lock | ||||||
Multimeter features | ||||||
AC/DC volts | Note: Not all product features and specifications are listed in this table. For more complete information, see individual product data sheets. Footnotes: |
|||||
Current | ||||||
Resistance | ||||||
Continuity beeper | ||||||
Temperature (contact) | ||||||
Lo-pass filter2 | ||||||
Capacitance | ||||||
Diode test | ||||||
Frequency | ||||||
MIN/MAX | ||||||
Other features | ||||||
Backlight | ||||||
Software | Fluke Connect compatible | FlukeView® Forms Basic | Fluke View® Forms Basic | |||
Battery | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | Rechargeable | Rechargeable |
Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.
Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.
Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Click on a category to view a selection of compatible accessories with the Rental - Fluke 1587FC Insulation Multimeter.
AC Voltage Measurements | |
Range | 600 mV 6 V 60 V 600 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
50 to 60 Hz ±(% of Rdg + counts) | ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3) |
60 to 5000 Hz ±(% of Rdg + counts) | ±(2% + 3) ±(2% + 3) ±(2% + 3) ±(2% + 3)1 ±(2% + 3)1 |
Low-Pass Filter Voltage | |
Range | 600 mV 6 V 60 V 600 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
50 to 60 Hz ±(% of Rdg + counts) | ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3) |
60 to 400 Hz ±(% of Rdg + counts) | ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) |
DC Voltage Measurement | |
Range | 6 V DC 60 V DC 600 V DC 1000 V DC |
Resolution | 0.001 V 0.01 V 0.1 V 1 V |
Accuracy ±(% of Rdg + Counts) | ±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2) |
Input Impedance | 10 MΩ (nominal), <100 pF |
Nominal Mode Rejection Ratio | >60 dB at 50 or 60 Hz |
Common Mode Rejection Ratio | >120 dB at DC, 50 or 60 Hz (1 k unbalance) |
DC Millivolts Measurement | |
Range | 600 mV DC |
Resolution | 0.1 mV |
Accuracy ±(% of Rdg + Counts) | ±(0.1 + 1) |
DC and AC Current Measurement | |
Range | 400 mA |
Resolution | 0.1 mA |
Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)1 |
Burden Voltage (Typical) | 2 mV/mA |
Range | 60 mA |
Resolution | 0.01 mA |
Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)1 |
Burden Voltage (Typical) | 2 mV/mA |
DC | |
Range | 400 mA |
Resolution | 0.1 mA |
Accuracy ±(% of Rdg+Counts) | ±(0.2% + 2) |
Burden Voltage (Typical) | 2 mV/mA |
Range | 60 mA |
Resolution | 0.01 mA |
Accuracy ±(% of Rdg+Counts) | ±(0.2% + 2) |
Burden Voltage (Typical) | 2 mV/mA |
Overload | 600 mA for 2 minutes maximum |
Fuse Protection for mA Input | 0.44 mA, 1000 V, IR 10 kA |
AC Conversion | Inputs are ac-coupled and calibrated to the RMS value of sine wave input |
Ohms Measurement | |
Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 50 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy +(% of Rdg+Counts)1 | ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(1.5% + 3) |
Overload Protection | 1000 RMS or DC |
Open Circuit Test Voltage | <8 V DC |
Short Circuit Current | <1.1 mA |
Diode Test | |
Diode Test Indication | Display voltage drop: 0.6 V at 1.0 mA nominal test current |
Accuracy | ±(2% + 3) |
Continuity Test | |
Continuity Indication | Continuous audible tone for test resistance below 25 Ω and off above 100 Ω Maximum reading: 1000 Ω |
Open Circuit Voltage | <8.0 V |
Short Circuit Current | 1.0 mA typical |
Overload Protection | 1000 V RMS |
Response Time | >1 m sec |
Frequency Measurement | |
Range | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy ±(% of Rdg+Counts) | ±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1) |
Frequency Counter Sensitivity | |
600.0 mV AC | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 mV V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 150.0 mV DC Trigger Levels¹ to 20 kHz2: NA |
6.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 1.0 V V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 1.5 V DC Trigger Levels¹ to 20 kHz2: -400.0 mV and 2.5 V |
60.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 10.0 V V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 36.0 V DC Trigger Levels¹ to 20 kHz2: 1.2 V and 4.0 V |
600.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 V V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V |
1000.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 300.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V |
Capacitance | |
Range | 1000 nF 10.00 µF 100.0 µF 9999 µF |
Resolution | 1 nF 0.01 µF 0.1 µF 1 µF |
Accuracy ±(% of Rdg+Counts) | ±(1.2% + 2) ±(1.2% + 2) ±(1.2% ± 90 counts) ±(1.2% ± 90 counts) |
Temperature Measurement | |
Range | -40 to 998°F (-40 to 537°C) |
Resolution | 0.1°F (0.1°C) |
Accuracy ±(% of Rdg+Counts)1 | ±(1% + 10 counts) ±(1% + 18 counts) |
Insulation Specifications | |
Measurement Range | 0.01 MΩ to 2 GΩ |
Test Voltages | 50, 100, 250, 500, 1000 V |
Test Voltage Accuracy | 20%, 0% |
Short-Circuit Test Current | 1 mA nominal |
Auto Discharge | Discharge time <0.5 second for C=1 µF or less |
Live Circuit Detection | Inhibit test if terminal voltage >30 V prior to initialization of test |
Maximum Capacitive Load | Operable with up to 1 µF load |
Output Voltage | |
50 V (0% to +20%) | Display range: 0.01 to 6.00 MΩ Resolution: 0.01 MΩ Test current: 1 mA at 50 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 50.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 50 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) |
100 V (0% to +20%) | Display range: 0.01 to 6.00 MΩ Resolution: 0.01 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 100.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) |
250 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 250 MΩ Resolution: 1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) |
500 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 500 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 500 MΩ Resolution: 1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) |
1000 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 600 MΩ Resolution: 1 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 0.6 to 2.0 GΩ Resolution: 100 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts) |
Two in one tools | Stand-alone tools | |||||
---|---|---|---|---|---|---|
Insulation test features | 1587 FC | 1577 | 1503 | 1507 | 1550C | 1555 |
Test voltages | 50 V, 100 V, 250 V, 500 V, 1000 V | 500 V, 1000 V | 500 V, 1000 V | 50 V, 100 V, 250 V, 500 V, 1000 V | 250 V to 5000 V | 250 V to 10,000 V |
Insulation resistance range | 0.01 MΩ to 2 GΩ | 0.01 MΩ to 600 GΩ | 0.01 MΩ to 2000 GΩ | 0.01 MΩ to 10 GΩ | 250 kΩ to 1 TΩ | 250 kΩ to 2 TΩ |
PI/DAR | ||||||
Auto discharge | ||||||
Timed ramp test (Breakdown) | ||||||
Pass/fail comparison | ||||||
Est. # of IRT tests | 1000 | 1000 | 2000 | 2000 | Various | Various |
Voltage > 30 V warning | ||||||
Memory | With Fluke Connect App | |||||
Remote test probe | ||||||
Lo ohms/earth-bond continuity | 200 mA source (10 mΩ resolution) | 200 mA source (10 mΩ resolution) | ||||
Display | Digital LCD | Digital LCD | Digital LCD | Digital LCD | Digital LCD/ analog display | Digital LCD/ analog display |
Hold/lock | ||||||
Multimeter features | ||||||
AC/DC volts | Note: Not all product features and specifications are listed in this table. For more complete information, see individual product data sheets. Footnotes: |
|||||
Current | ||||||
Resistance | ||||||
Continuity beeper | ||||||
Temperature (contact) | ||||||
Lo-pass filter2 | ||||||
Capacitance | ||||||
Diode test | ||||||
Frequency | ||||||
MIN/MAX | ||||||
Other features | ||||||
Backlight | ||||||
Software | Fluke Connect compatible | FlukeView® Forms Basic | Fluke View® Forms Basic | |||
Battery | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | 4 AA (NEDA 15A or IEC LR6) | Rechargeable | Rechargeable |
Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.
Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.
Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Click on a category to view a selection of compatible accessories with the Rental - Fluke 1587FC Insulation Multimeter.