Ideal for many AC only current measurement situations, this True RMS AC clamp meter measures up to 600 A AC and 600 V ac or DC. This unit automatically sets the right measurement range depending on the present voltage when you power up. It can as well measure DC voltage of up to 600 V and resistance up to 6000 Ω.
Ideal for many AC only current measurement situations, this True RMS AC clamp meter measures up to 600 A AC and 600 V ac or DC. This unit automatically sets the right measurement range depending on the present voltage when you power up. It can as well measure DC voltage of up to 600 V and resistance up to 6000 Ω.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
True RMS AC Clamp Meter does the job for any AC-only current measurement application
Ideal for AC-only current measurement situations, this clamp meter features True RMS AC voltage and current measurements. This unit allows you to measure AC current of up to 600 A, AC voltage up to 600V, DC voltage up to 600 V, and resistance to 6000 Ω.
To simplify the usage, it features a large, easy-to-read backlit display, which provides better visibility in dimly lit conditions. Additionally, this meter automatically sets the proper measurement range based on the present voltage when you power it up, so you don't have to move the switch while taking the measurement.
Features
Measurement capability
Applications
AC Current | |
Range | 600.0 A |
Resolution | 0.1 A |
Accuracy | 2% ± 5 digits (48 to 62 Hz) |
Crest Factor (50/60 Hz) | 2.5 at 600 A |
AC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1.0% ± 5 digits (48 to 62 Hz) |
DC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1% ± 5 digits |
Resistance | |
Range | 600.0/6000 Ω |
Resolution | 0.1/1 Ω |
Accuracy | 1% ± 5 digits |
Continuity Beeper | 30 Ω |
Capacitance | |
Range | 10.0 to 100.0 μF/1000 μF |
Resolution | 0.1/1 μF |
Accuracy | 1.9% ± 2 digits |
Environmental Specifications | |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Operating Humidity | Non condensing at 50°F (<10°C) ≤90% RH at 50 to 86°F (10 to 30°C) ≤75% RH at 86 to 104°F (30 to 40°C) ≤45% RH at 104 to 122°F (40 to 50°C) (Without condensation) |
Operating Altitude | 9842.52' (3000 m) |
Storage Altitude | 39,370.1' (12,000 m) |
EMI, EMC | Meets all applicable requirements in EN61326-1:2006 |
Temperature Coefficients | Add 0.1 x specified accuracy for each °C above 28°C or below 18°C |
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV Pollution Degree 2 EN/IEC 61010-2-32:2002 EN/IEC 61010-031:2002/A1:2008 |
General Specifications | |
Batteries | 2 x AA NEDA 15 A IEC LR6 |
Dimensions | 9.1 x 3.35 x 1.8" (232 x 85 x 45 mm) |
Weight | 0.82 lbs (370 g) |
Click on a category to view a selection of compatible accessories with the Fluke 373 True RMS AC Clamp Meter, 600 A.
AC Current | |
Range | 600.0 A |
Resolution | 0.1 A |
Accuracy | 2% ± 5 digits (48 to 62 Hz) |
Crest Factor (50/60 Hz) | 2.5 at 600 A |
AC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1.0% ± 5 digits (48 to 62 Hz) |
DC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1% ± 5 digits |
Resistance | |
Range | 600.0/6000 Ω |
Resolution | 0.1/1 Ω |
Accuracy | 1% ± 5 digits |
Continuity Beeper | 30 Ω |
Capacitance | |
Range | 10.0 to 100.0 μF/1000 μF |
Resolution | 0.1/1 μF |
Accuracy | 1.9% ± 2 digits |
Environmental Specifications | |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Operating Humidity | Non condensing at 50°F (<10°C) ≤90% RH at 50 to 86°F (10 to 30°C) ≤75% RH at 86 to 104°F (30 to 40°C) ≤45% RH at 104 to 122°F (40 to 50°C) (Without condensation) |
Operating Altitude | 9842.52' (3000 m) |
Storage Altitude | 39,370.1' (12,000 m) |
EMI, EMC | Meets all applicable requirements in EN61326-1:2006 |
Temperature Coefficients | Add 0.1 x specified accuracy for each °C above 28°C or below 18°C |
Safety Compliance | ANSI/ISA S82.02.01:2004 CAN/CSA-C22.2 No. 61010-1-04 IEC/EN 61010-1:2001, 600V CAT III, 300V CAT IV Pollution Degree 2 EN/IEC 61010-2-32:2002 EN/IEC 61010-031:2002/A1:2008 |
General Specifications | |
Batteries | 2 x AA NEDA 15 A IEC LR6 |
Dimensions | 9.1 x 3.35 x 1.8" (232 x 85 x 45 mm) |
Weight | 0.82 lbs (370 g) |
Click on a category to view a selection of compatible accessories with the Fluke 373 True RMS AC Clamp Meter, 600 A.