Fluke 393FC True-rms Clamp Meter with iFlex, CAT III 1500 V, 1500 V DC/1000 V AC/ 999.9 A DC or AC

Model: 393FC | Order No: 393 FC | UPC: 195112019382

Fluke 393FC True-rms Clamp Meter with iFlex, CAT III 1500 V, 1500 V DC/1000 V AC/ 999.9 A DC or AC

Model: 393FC | Order No: 393 FC | UPC: 195112019382

Ideal for technicians who work in dc environments up to 1500 V, this true-rms clamp meter features a slim jaw to allow access to crowded combiner boxes and is IP54 rated for work outdoors. In addition, this meter features a flexible current probe that extends AC current measurements up to 2500 A.

Ideal for technicians who work in dc environments up to 1500 V, this true-rms clamp meter features a slim jaw to allow access to crowded combiner boxes and is IP54 rated for work outdoors. In addition, this meter features a flexible current probe that extends AC current measurements up to 2500 A.

Sale Price $663.99 USD
Regular Price $799.99 USD
Availability 2 in Stock
Quantity

Traceable In-House Calibration Certificate for your 393FC True-rms Clamp Meter with iFlex

Traceable In-House Calibration Certificate for your 393FC True-rms Clamp Meter with iFlex

Fluke 393FC Offers

Work efficiently with this true-rms clamp meter which features DC power measurement, audio polarity, and visual continuity. Additionally, this meter features wireless transmission and saves test results to a smartphone or the cloud to save time and eliminate data-entry errors.

Features

  • IP54 rated, ideal for work outdoors in dusty or damp conditions on solar arrays and wind power systems
  • DC power measurement, showing readings in kVA
  • Audio polarity indicator helps prevent accidental miswires
  • Visual continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
  • Logging and reporting of test results via software
  • Measure safely with CAT III 1500 V rated clamp meter
  • Thin jaw for access to cables in crowded combiner boxes, able to clamp around multiple cables
  • MC4 test lead sets are designed for use with solar clamp meters that accept 0.15" (4 mm) banana plugs, rated to CAT III 1000 V / CAT IV 600 V
  • View voltage and current simultaneously with the meter's dual display

Applications

  • Solar arrays
  • Wind power
  • Electric railways
  • Data centers
  • Battery Banks for uninterruptible power supplies

Fluke 393FC Specifications

Maximum Voltage Between Any Terminal and Earth Ground 1000 V AC
1500 V DC
Electrical Specifications Accuracy: Accuracy is specified for 1 year after calibration, at operating temperatures of 64.4 to 82.4°F (18 to 28°C), relative humidity at 0 to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
Temperature coefficients: Add 0.1 x specified accuracy for each °C > 64.4°F (28°C) or <82.4°F (18°C)
AC Current: Jaw Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% + 5 digits (10 to 100 Hz); 2.5% + 5 digits (100 to 500 Hz)

Crest factor (50/60 Hz):
2.5 at 600 A
3 at 500 A
1.42 at 999.9 A
Add 2% for C.F. >2
AC Current: Flexible Current Probe Range: 999.9 A; 2500 A
Resolution: 0.1 A (≤999.9 A); 1 A (≤2500 A)
Accuracy: 3 % RD + 5 digits (10 to 500 Hz)Crest factor (50/60Hz):
2.5 at 1400 A
3 at 1100 A
1.42 at 2500 A
Add 2% for C.F. >2
Position Sensitivity Distance from optimum:
A
B
C

i2500-18 Flex:
1.4" (35.6 mm)
2" (50.8 mm)
2.5" (63.5 mm)

Error:
±0.5%
±1%
±2%
DC Current Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% RD + 5 digits, When using the ZERO function to compensate for offsets
AC Voltage Range: 600 V; 1000 V
Resolution: 0.1 V (≤600 V); 1 V (≤1000 V)
Accuracy: 1% RD + 5 digits (20 to 500 Hz)
DC Voltage Range: 600 V; 1500
Resolution: 0.1 V (≤600 V), 1 V (≤1500 V)
Accuracy: 1% RD + 5 digits
mV DC Range: 500 mV
Resolution: 0.1 mV
Accuracy: 1% RD + 5 digits
Amps Frequency: Jaw Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 10 Hz ≥10 A
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
Amps Frequency: Flexible Current Probe Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 10 Hz ≥10 A
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
Voltage Frequency Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 20 Hz, ≥5 V
20 to 100 Hz, ≥5 V
100 to 500 Hz, ≥10 V
DC Power Range: 600 kVA (600 V DC range), 1500 kVA (1500 V DC range)
Resolution: 0.1 kVA, 1 kVA
Accuracy: 2% RD + 2 kVA, 2% RD + 20 kVA
Resistance Range: 600 Ω, 6000 Ω, 60 kΩ
Resolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 0.01 kΩ (≤60 kΩ)
Accuracy: 1% RD + 5 digits
Capacitance Range: 100 μF, 1000 μF
Resolution: 0.1 μF (≤100 μF), 1 μF (≤1000 μF)
Accuracy: 1% RD + 5 digits
Inrush trigger level: 5 A
Temperature Operating: 14 to 122°F (-10 to 50°C)
Storage: -40 to 140°F (-40 to 60°C)
Operating Humidity Non-condensing <50°F (10°C)
≤90% RH at 50 to 86°F (10 to 30°C)
≤75% RH at 86 to 104°F (30 to 40°C)
≤45% RH at 104 to 122°F (40 to 50°C)
Altitude Operating: 6561.68' (2000 m)
Storage: 39,370.07' (12,000 m)
Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC): Class A equipment (Industrial Broadcast and Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety General: IEC 61010-1, Pollution Degree 2

Measurement:
IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless Radio Radio frequency certification: FCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless radio frequency range: 2400 to 2483.5 MHz
Output power: <100 mW
SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
Automatic Power Off 20 minutes
Display Dual display with backlight
Batteries Two AA IEC LR6 alkaline
Dimensions Size: 11.06 x 3.3 x 1.92" (281 x 84 x 49 mm)
Jaw opening: 1.33" (34 mm)
Flexible current probe diameter: 0.29" (7.5 mm)
Flexible current probe cable length (head to electronics connector): 0.07" (1.8 m)
Weight (With Batteries) 1.14 lbs (520 g)
Click here for complete specifications on the Fluke 393FC

What's included with the Fluke 393FC

  • Clamp Meter
  • Test Leads, Right Angle Plugs with Safety Caps
  • Flexible Current Probe
  • Magnetic Hanging Strap
  • Carrying Case
  • Three-Year Warranty

Webinar: EVSE Safety Maintenance with Fluke


In recent years, more people are opting for greener solutions to minimize environmental damage, which has led to an increased demand for environmentally safe solutions such as electric vehicles. Naturally, this has led to an increase in the installation of EV charging stations, but also the risks for technicians. In 2020, there were 126 fatal and 2200 non-fatal electrical injuries. Many of these are caused when technicians are exposed to hazardous voltage and arc faults that could cause shock and fire hazards due to a lack of understanding of proper EVSE installation and maintenance. Considering that EVSEs have a high rate of failure, estimated at 30 to 50% (SAE), reliability is essential when building EV infrastructure and gaining user acceptance.

Webinar: Solar Trends and Troubleshooting PV Systems with Fluke


In recent years, more and more people are opting for greener solutions to minimize environmental damage, which has led to an increased demand for environmentally safe solutions. As such, there are more efforts being made on using solar energy in various segments of our society. These changes also entail the need for tools that improve testing and troubleshooting solar solutions.

Click on a category to view a selection of compatible accessories with the Fluke 393FC True-rms Clamp Meter with iFlex, CAT III 1500 V, 1500 V DC/1000 V AC/ 999.9 A DC or AC.

Fluke Pack30 Professional Tool Backpack FlukePack30
A more comfortable solution than traditional tool belts that put all the weight on your lower back, or tool bags with awkward carrying straps. Backpacks offer a convenient method for organizing and storing your carrying tools.




Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke IRR1-SOL Solar Irradiance Meter, 0 to 1400 W/m2 IRR1-SOL
Designed to simplify the critical measurements needed for installing, testing, and maintaining solar panels or photovoltaic systems, the irradiance meter is an all-in-one, easy-to-use solution for solar installers. Its user interface and built-in temperature sensor make it easy to meet testing and documenting requirements.




Ask a question about Fluke 393FC True-rms Clamp Meter with iFlex, CAT III 1500 V, 1500 V DC/1000 V AC/ 999.9 A DC or AC

Customer Reviews for the Fluke 393FC

Fluke 393FC Offers

Work efficiently with this true-rms clamp meter which features DC power measurement, audio polarity, and visual continuity. Additionally, this meter features wireless transmission and saves test results to a smartphone or the cloud to save time and eliminate data-entry errors.

Features

  • IP54 rated, ideal for work outdoors in dusty or damp conditions on solar arrays and wind power systems
  • DC power measurement, showing readings in kVA
  • Audio polarity indicator helps prevent accidental miswires
  • Visual continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
  • Logging and reporting of test results via software
  • Measure safely with CAT III 1500 V rated clamp meter
  • Thin jaw for access to cables in crowded combiner boxes, able to clamp around multiple cables
  • MC4 test lead sets are designed for use with solar clamp meters that accept 0.15" (4 mm) banana plugs, rated to CAT III 1000 V / CAT IV 600 V
  • View voltage and current simultaneously with the meter's dual display

Applications

  • Solar arrays
  • Wind power
  • Electric railways
  • Data centers
  • Battery Banks for uninterruptible power supplies

Fluke 393FC Specifications

Maximum Voltage Between Any Terminal and Earth Ground 1000 V AC
1500 V DC
Electrical Specifications Accuracy: Accuracy is specified for 1 year after calibration, at operating temperatures of 64.4 to 82.4°F (18 to 28°C), relative humidity at 0 to 75%. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
Temperature coefficients: Add 0.1 x specified accuracy for each °C > 64.4°F (28°C) or <82.4°F (18°C)
AC Current: Jaw Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% + 5 digits (10 to 100 Hz); 2.5% + 5 digits (100 to 500 Hz)

Crest factor (50/60 Hz):
2.5 at 600 A
3 at 500 A
1.42 at 999.9 A
Add 2% for C.F. >2
AC Current: Flexible Current Probe Range: 999.9 A; 2500 A
Resolution: 0.1 A (≤999.9 A); 1 A (≤2500 A)
Accuracy: 3 % RD + 5 digits (10 to 500 Hz)Crest factor (50/60Hz):
2.5 at 1400 A
3 at 1100 A
1.42 at 2500 A
Add 2% for C.F. >2
Position Sensitivity Distance from optimum:
A
B
C

i2500-18 Flex:
1.4" (35.6 mm)
2" (50.8 mm)
2.5" (63.5 mm)

Error:
±0.5%
±1%
±2%
DC Current Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% RD + 5 digits, When using the ZERO function to compensate for offsets
AC Voltage Range: 600 V; 1000 V
Resolution: 0.1 V (≤600 V); 1 V (≤1000 V)
Accuracy: 1% RD + 5 digits (20 to 500 Hz)
DC Voltage Range: 600 V; 1500
Resolution: 0.1 V (≤600 V), 1 V (≤1500 V)
Accuracy: 1% RD + 5 digits
mV DC Range: 500 mV
Resolution: 0.1 mV
Accuracy: 1% RD + 5 digits
Amps Frequency: Jaw Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 10 Hz ≥10 A
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
Amps Frequency: Flexible Current Probe Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 10 Hz ≥10 A
10 to 100 Hz, ≥5 A
100 to 500 Hz, ≥10 A
Voltage Frequency Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% RD + 5 digits

Trigger level:
5 to 20 Hz, ≥5 V
20 to 100 Hz, ≥5 V
100 to 500 Hz, ≥10 V
DC Power Range: 600 kVA (600 V DC range), 1500 kVA (1500 V DC range)
Resolution: 0.1 kVA, 1 kVA
Accuracy: 2% RD + 2 kVA, 2% RD + 20 kVA
Resistance Range: 600 Ω, 6000 Ω, 60 kΩ
Resolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 0.01 kΩ (≤60 kΩ)
Accuracy: 1% RD + 5 digits
Capacitance Range: 100 μF, 1000 μF
Resolution: 0.1 μF (≤100 μF), 1 μF (≤1000 μF)
Accuracy: 1% RD + 5 digits
Inrush trigger level: 5 A
Temperature Operating: 14 to 122°F (-10 to 50°C)
Storage: -40 to 140°F (-40 to 60°C)
Operating Humidity Non-condensing <50°F (10°C)
≤90% RH at 50 to 86°F (10 to 30°C)
≤75% RH at 86 to 104°F (30 to 40°C)
≤45% RH at 104 to 122°F (40 to 50°C)
Altitude Operating: 6561.68' (2000 m)
Storage: 39,370.07' (12,000 m)
Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC): Class A equipment (Industrial Broadcast and Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety General: IEC 61010-1, Pollution Degree 2

Measurement:
IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless Radio Radio frequency certification: FCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless radio frequency range: 2400 to 2483.5 MHz
Output power: <100 mW
SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
Automatic Power Off 20 minutes
Display Dual display with backlight
Batteries Two AA IEC LR6 alkaline
Dimensions Size: 11.06 x 3.3 x 1.92" (281 x 84 x 49 mm)
Jaw opening: 1.33" (34 mm)
Flexible current probe diameter: 0.29" (7.5 mm)
Flexible current probe cable length (head to electronics connector): 0.07" (1.8 m)
Weight (With Batteries) 1.14 lbs (520 g)
Click here for complete specifications on the Fluke 393FC

What's included with the Fluke 393FC

  • Clamp Meter
  • Test Leads, Right Angle Plugs with Safety Caps
  • Flexible Current Probe
  • Magnetic Hanging Strap
  • Carrying Case
  • Three-Year Warranty

Webinar: EVSE Safety Maintenance with Fluke


In recent years, more people are opting for greener solutions to minimize environmental damage, which has led to an increased demand for environmentally safe solutions such as electric vehicles. Naturally, this has led to an increase in the installation of EV charging stations, but also the risks for technicians. In 2020, there were 126 fatal and 2200 non-fatal electrical injuries. Many of these are caused when technicians are exposed to hazardous voltage and arc faults that could cause shock and fire hazards due to a lack of understanding of proper EVSE installation and maintenance. Considering that EVSEs have a high rate of failure, estimated at 30 to 50% (SAE), reliability is essential when building EV infrastructure and gaining user acceptance.

Webinar: Solar Trends and Troubleshooting PV Systems with Fluke


In recent years, more and more people are opting for greener solutions to minimize environmental damage, which has led to an increased demand for environmentally safe solutions. As such, there are more efforts being made on using solar energy in various segments of our society. These changes also entail the need for tools that improve testing and troubleshooting solar solutions.

Click on a category to view a selection of compatible accessories with the Fluke 393FC True-rms Clamp Meter with iFlex, CAT III 1500 V, 1500 V DC/1000 V AC/ 999.9 A DC or AC.

Fluke Pack30 Professional Tool Backpack FlukePack30
A more comfortable solution than traditional tool belts that put all the weight on your lower back, or tool bags with awkward carrying straps. Backpacks offer a convenient method for organizing and storing your carrying tools.




Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke IRR1-SOL Solar Irradiance Meter, 0 to 1400 W/m2 IRR1-SOL
Designed to simplify the critical measurements needed for installing, testing, and maintaining solar panels or photovoltaic systems, the irradiance meter is an all-in-one, easy-to-use solution for solar installers. Its user interface and built-in temperature sensor make it easy to meet testing and documenting requirements.




Ask a question about Fluke 393FC True-rms Clamp Meter with iFlex, CAT III 1500 V, 1500 V DC/1000 V AC/ 999.9 A DC or AC

Customer Reviews for the Fluke 393FC

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.

Calibration Lab