Take measurement temperature with this infrared and contact thermometer. Users can quickly navigate advanced features to adjust emissivity, start data logging, or turn alarms on and off with the push of a few buttons. Additionally, this tool features a simple, three-button, and on-screen menu interface (in 6 languages).
Take measurement temperature with this infrared and contact thermometer. Users can quickly navigate advanced features to adjust emissivity, start data logging, or turn alarms on and off with the push of a few buttons. Additionally, this tool features a simple, three-button, and on-screen menu interface (in 6 languages).
Features
Applications
Infrared Temperature Range | -40 to 1202°F (-40 to 650°C) |
Infrared Accuracy | <32°F (0°C): ±(2.0°F (±1.0°C) + 0.1°/1°F or °C) >32°F (0°C): ±1% or ±2.0°F (±1.0°C), whichever is greater |
Display Resolution | 0.1°F (0.1°C) |
Infrared Spectral Response | 8 to 14 µm |
Infrared Response Time | <500 msec |
Thermocouple Type-K Input Temperature Range | -454 to 2501°F (-270 to 1372°C) |
Thermocouple Type-K Input Accuracy | -454 to -40 (-270 to -40°C): ±(2°F + 0.2°/1°F) (±[1°C + 0.2°/1°C]) -40 to 2501.6°F (-40 to 1372°C): ±1% or 2°F (±1% or 1°C), whichever is greater |
Distance to Measurement Spot Size | 30:1 |
Laser Sighting | Single-point laser <1 mw output Class 2 (II) operation, 630 to 670 nm |
Minimum Spot Size | 0.75" (19 mm) |
Emissivity Adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 |
Data Storage with Date/Time Stamp | 20 points |
PC Interface and Cable | None |
Hi/Low Alarms | Audible and two-color visual |
Min/Max/Avg/Dif | Yes |
Display | Dot matrix 98 x 96 pixels with function menus |
Backlight | Two levels, normal and extra bright for darker environments |
Trigger Lock | Yes |
Switchable Celsius and Fahrenheit | Yes |
Power | 2 x AA/LR6 Batteries |
Battery Life | Laser and backlight on, 12 hours (used continuously) Laser and backlight off, 100 hours (used continusously) |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | -40 to 140°F (-20 to 60°C) |
Bead Thermocouple Type-K Range | -40 to 500°F (-40 to 260°C) |
Bead Thermocouple Type-K Accuracy | ±2.0°F (1.1°C) from 32 to 500°F (0 to 260°C), typically within 2.0°F (1.1°C) from -40 to 32°F (-40 to 0°C) |
Click on a category to view a selection of compatible accessories with the Fluke 566 Infrared (IR) and Contact Thermometer.
Infrared Temperature Range | -40 to 1202°F (-40 to 650°C) |
Infrared Accuracy | <32°F (0°C): ±(2.0°F (±1.0°C) + 0.1°/1°F or °C) >32°F (0°C): ±1% or ±2.0°F (±1.0°C), whichever is greater |
Display Resolution | 0.1°F (0.1°C) |
Infrared Spectral Response | 8 to 14 µm |
Infrared Response Time | <500 msec |
Thermocouple Type-K Input Temperature Range | -454 to 2501°F (-270 to 1372°C) |
Thermocouple Type-K Input Accuracy | -454 to -40 (-270 to -40°C): ±(2°F + 0.2°/1°F) (±[1°C + 0.2°/1°C]) -40 to 2501.6°F (-40 to 1372°C): ±1% or 2°F (±1% or 1°C), whichever is greater |
Distance to Measurement Spot Size | 30:1 |
Laser Sighting | Single-point laser <1 mw output Class 2 (II) operation, 630 to 670 nm |
Minimum Spot Size | 0.75" (19 mm) |
Emissivity Adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 |
Data Storage with Date/Time Stamp | 20 points |
PC Interface and Cable | None |
Hi/Low Alarms | Audible and two-color visual |
Min/Max/Avg/Dif | Yes |
Display | Dot matrix 98 x 96 pixels with function menus |
Backlight | Two levels, normal and extra bright for darker environments |
Trigger Lock | Yes |
Switchable Celsius and Fahrenheit | Yes |
Power | 2 x AA/LR6 Batteries |
Battery Life | Laser and backlight on, 12 hours (used continuously) Laser and backlight off, 100 hours (used continusously) |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | -40 to 140°F (-20 to 60°C) |
Bead Thermocouple Type-K Range | -40 to 500°F (-40 to 260°C) |
Bead Thermocouple Type-K Accuracy | ±2.0°F (1.1°C) from 32 to 500°F (0 to 260°C), typically within 2.0°F (1.1°C) from -40 to 32°F (-40 to 0°C) |
Click on a category to view a selection of compatible accessories with the Fluke 566 Infrared (IR) and Contact Thermometer.