Rugged construction with an easy-to-use interface, this single function thermocouple temperature calibrator measures 4 to 20mA signals while sourcing a temperature signal. Featuring intelligent shutdown, the calibrator remembers settings when powered down so you don't have to, and can replicate tests after powering back up.
Rugged construction with an easy-to-use interface, this single function thermocouple temperature calibrator measures 4 to 20mA signals while sourcing a temperature signal. Featuring intelligent shutdown, the calibrator remembers settings when powered down so you don't have to, and can replicate tests after powering back up.
Delivering outstanding performance, this thermocouple calibrator presents durability and reliability. The calibrator is compact, lightweight, and offers an easy-to-use push-button interface. It is EMI tolerant, dust and splash resistant, and features a removable battery door for quick battery changes.
Features
Applications
Thermocouple mV Input | |
Range | -10 to 75 mV |
Resolution | 0.001 mV |
Accuracy (% of Reading + Floor) | 1 year: 0.015 % + 10 µV 2 year: 0.02 % + 15 µV (2 year) |
Thermocouple mV Output | |
Range | -10 to 75 mV |
Resolution | 0.01 mV |
Accuracy (% of Output + Floor) | 1 year: 0.015 % + 10 µV 2 year: 0.02 % + 15 µV |
Thermocouple mA Input | |
Range | 0 to 24 mA |
Resolution | 0.001 mA |
Accuracy (% of Reading + Floor) | 1 year: 0.01 % + 2 µA 2 year: 0.02 % + 4 µA |
General Specifications | |
Maximum Voltage Applied Between any Terminal and Earth Ground or Between any Two Terminals | 30 V |
Temperature | Operating: -10 to 50 °C Storage: -20 to 60 °C |
Altitude | Operating: 6561' (2000 m) Storage: 39,370' (12,000 m) |
Relative Humidity (% RH Operating without Condensation) | Non-condensing 90% (10 to 30 °C) 75% (30 to 40 °C) 45% (40 to 50 °C) |
Vibration Requirements | MIL-T-28800E, Class 2 |
Drop Test Requirements | 3.2' (1 m) |
IP Rating | IEC 60529: IP52 (with TC cap) |
Electromagnetic Environment | IEC 61326-1, Portable |
Safety | IEC 61010-1, Max 30 V to earth, Pollution Degree 2 |
Power Supply | 4 AA alkaline batteries/NEDA code: 15A, IEC code: LR6 |
Dimensions | 0.4 x 3.3 x 7.4" (52.5 x 84 x 188.5 mm) |
Weight | 1.13 lbs (515 g) |
Click on a category to view a selection of compatible accessories with the Fluke 714B Temperature Calibrator, 4 to 20 mA.
Thermocouple mV Input | |
Range | -10 to 75 mV |
Resolution | 0.001 mV |
Accuracy (% of Reading + Floor) | 1 year: 0.015 % + 10 µV 2 year: 0.02 % + 15 µV (2 year) |
Thermocouple mV Output | |
Range | -10 to 75 mV |
Resolution | 0.01 mV |
Accuracy (% of Output + Floor) | 1 year: 0.015 % + 10 µV 2 year: 0.02 % + 15 µV |
Thermocouple mA Input | |
Range | 0 to 24 mA |
Resolution | 0.001 mA |
Accuracy (% of Reading + Floor) | 1 year: 0.01 % + 2 µA 2 year: 0.02 % + 4 µA |
General Specifications | |
Maximum Voltage Applied Between any Terminal and Earth Ground or Between any Two Terminals | 30 V |
Temperature | Operating: -10 to 50 °C Storage: -20 to 60 °C |
Altitude | Operating: 6561' (2000 m) Storage: 39,370' (12,000 m) |
Relative Humidity (% RH Operating without Condensation) | Non-condensing 90% (10 to 30 °C) 75% (30 to 40 °C) 45% (40 to 50 °C) |
Vibration Requirements | MIL-T-28800E, Class 2 |
Drop Test Requirements | 3.2' (1 m) |
IP Rating | IEC 60529: IP52 (with TC cap) |
Electromagnetic Environment | IEC 61326-1, Portable |
Safety | IEC 61010-1, Max 30 V to earth, Pollution Degree 2 |
Power Supply | 4 AA alkaline batteries/NEDA code: 15A, IEC code: LR6 |
Dimensions | 0.4 x 3.3 x 7.4" (52.5 x 84 x 188.5 mm) |
Weight | 1.13 lbs (515 g) |
Click on a category to view a selection of compatible accessories with the Fluke 714B Temperature Calibrator, 4 to 20 mA.