Fluke FLUKE-754/750SW BU Documenting Process Calibrator and DPC/TRACK2 Software Bundle

Model: FLUKE-754/750SW BU | Order No: 754/750SW-BU | UPC: 095969724166

Fluke FLUKE-754/750SW BU Documenting Process Calibrator and DPC/TRACK2 Software Bundle

Model: FLUKE-754/750SW BU | Order No: 754/750SW-BU | UPC: 095969724166

Your Price $13208.99 USD
Availability 2 to 3 Weeks
Quantity

Fluke FLUKE-754/750SW BU Offers



The Fluke 754/750SW BU Documenting Process Calibrator with Hart communication and DPC/TRACK2 software kit provides full control over system management. The kit includes the necessary clips to accommodate any circuit setup. The included accessories allow for full functionality and easy transportation of the kit around the workplace.

Features

  • Several clip types to accommodate different systems
  • Communication cable improves connection to compatible systems
  • Designed to troubleshoot HART connections and calibration

Fluke FLUKE-754/750SW BU Specifications


SoftwareDPC/TRACK2
CommunicationHart
Click here for complete specifications on the Fluke FLUKE-754/750SW BU

What is HART?

HART, the Highway Addressable Remote Transducer protocol, uses a 1200 baud Frequency Shift Keying (FSK) signal to superimpose digital information on the conventional 4 to 20 mA analog signal.

Why use the HART protocol?

HART is an industry standard developed to define the communications protocol between intelligent field devices and a control system, HART is the most widely used digital communication protocol in the process industry. More than five million HART field instruments are installed in more than 100,000 plants worldwide. The HART protocol:

  • Is supported by all of the major suppliers of process field instruments supported by the HART Communication Foundation, an industry-wide non-profit organization
  • Preserves present control strategies
  • Allows traditional 4 to 20 mA signals and digital communication to share the same two-wire loops
  • Provides important information for installation and maintenance: Tag IDs, measured values, range and span data, product information and diagnostics
  • Reduces operation costs by making it easier to manage and fully utilize "smart" instrument network

Fluke 754 HART Documenting Process Calibrator:
Get HART-ability

Process plants have taken advantage of smart transmitters, the need for a new generation of calibrators has emerged - calibrators that can communicate via industry standard digital protocols. This process calibrator combines HART communication capability in a documenting process calibrator to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART instrumentation. This process calibrator offers:

  • Integrated HART communication functions, permitting you to monitor, control, and calibrate HART instrumentation
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 mS
  • Li-ion battery with 4400 mA hour life and gas gauge
Fluke 754 Documenting Process Calibrator With HART Communication

The field calibrator for HART instruments that's both powerful and easy to use

This process calibrator offers the most complete HART implementation of any process calibrator. This process calibrator:

  • Requires no external box or second tool for everyday HART calibration and maintenance
  • Offers fast HART communication
  • Supports popular models of HART transmitters with device-specific command support
  • Fully complies with the Data Link Layer of the HART protocol, including multiple masters, burst mode, and multi-drop configurations
  • Is easy to update as additional instruments are added and new HART versions are released
  • Is based on the 740 series calibrators, the most rugged, reliable multifunction field calibrators ever made
  • Is backed by the service and support of the Fluke organization, a member of the HART Communications Foundation

This process calibrator is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers many of the communication capabilities of the 475 HART communicator except for the DD interpreter, which can read command set libraries from any HART supplier. This is not necessary for daily HART maintenance.


How to calibrate a HART smart pressure transmitter

Calibrating a HART Smart Pressure Transmitter

Pressure transmitter manufacturers have improved the accuracy and technology designed into these smart pressure measurement devices. Many conventional calibration tools have become inadequate or simply unable to test and calibrate these high accuracy pressure transmitters. Better test solutions are required.

Verifying and documenting the performance and adjusting a HART smart pressure transmitter can require a bucket full of tools. Performing this task with a HART enabled calibrator like this process calibrator simplifies the task and reduces what you need to carry.

Before going to the field, install the pressure module adapter to the hand pump with thread seal. Once the adapter is properly installed on the pump, changing modules to different pressure ranges is a snap, no tools required.

To get the accuracy needed to test these new high accuracy transmitters, match the pressure measurement standard range closely to the device tested. For example, use a 100 psi pressure module to calibrate and test a transmitter ranged at 100 psi. Industry standards suggest the measurement standard should be 4 to 10 times more accurate than the device being tested, so best-in-class accuracy is required.

This Documenting Process Calibrator-HART utilizes the 750P series pressure module and has the HART functionality built in to enable smart trims on transmitters. It can also document transmitter performance before and after adjustment and calculate pass/fail errors.

To perform the test:

  1. Isolate the transmitter from the process being measure and its loop wiring. If measuring the mA signal across the transmitter test diode leave the wires intact, but note this method does not give the best mA measurement accuracy.
  2. Connect the mA measurement jacks of this process calibrator to the transmitter.
  3. Connect the pressure module cable to this process calibrator and connect the transmitter test hose from the hand pump to the transmitter.
  4. Press the HART button on the calibrator to see the configuration of the transmitter.
  5. Press HART again and the calibrator will offer the correct measure/source combination for the test. If documenting the calibration press As-Found, input the test tolerance and follow the prompts. If the measured mA signal at the test points is found within tolerance the test is complete. If not, adjustment is required.
  6. Select, adjust, and trim the pressure zero, mA output signal and input sensor.
  7. After adjustment select As-Left, document the condition of the transmitter and after adjustment and if the test passes, it is complete.

HART applications

Fluke 754: The HART calibrator that is easy to use.
Versatile HART protocol support

This process calibrator supports the commands contained in HART protocol version 5.7.
This process calibrator supports a substantial set of HART instructions:

  • Universal commands - provide functions that are implemented in all field devices, for example, read manufacturer and device type, read primary variable (PV), or read current output and percent of span
  • Common practice commands - provide functions that are common to many but not all field devices, for example read multiple variables, set damping time, or perform loop test
  • Device-specific commands - provide functions that are unique to a particular field device, for example sensor trim

Today's 754 supports device-specific instructions for a variety of popular instruments. Additional support may be added periodically with a simple software update available on diskette or via download for a modest upgrade fee.

Manufacturer Pressure Instruments Temperature Instruments Coriolis Instruments
ABB/Kent-Taylor 600T 658T1
ABB/Hartmann & Braun Contrans P1, AS 800 Series
Endress & Hauser CERABAR S, CERABAR M, DELTABAR S TMT 1221, TMT 1821, TMT 1621
Foxboro Eckardt TI/RTT201
Foxboro/Invensys I/A Pressure
Fuji FCX, FCXAZ FRC
Honeywell ST3000 STT25T1, STT25H1
Micro Motion 2000, 2000IS, 9701, 9712, 9739
Moore Products 3441
Rosemount 1151, 2088, 3001C, 3051, 3051S 3044C, 644, 3144, 3244, 3144P
Siemens SITRANS P DS
SMAR SITRANS P DS, SITRANS P ES
Viatran LD301 TT3011
Wika UNITRANS
Yokogawa EJA YTA 110, 310 and 320

1Sensor trim not supported

Fluke 754 Documenting Process Calibrator

HART Operating Modes Supported

  • For Point to Point operation, the most commonly used mode, connects this process calibrator to a single HART device in a 4 to 20 mA loop.
  • In Multi-Drop mode, several HART instruments can be bussed together. This process calibrator searches for each, identifies addresses in use, and allows you to select the instrument for calibration and related operations.
  • In Burst Mode, the HART instrument transmits bursts of data without waiting to be interrogated by a master unit. This process calibrator can take transmitters out of burst mode during test or calibration, then later restore them to burst mode.

This Fluke FLUKE-754/750SW BU Documenting Process Calibrator and DPC/TRACK2 Software Bundle Includes


Fluke 754 Documenting Process Calibrator with HART communication

Rugged and compact, this documenting process calibrator is powerful yet easy to use. Ideal for troubleshooting HART instrumentation, the calibrator offers communication and calibration functions in one tool. With a bright display and multi-lingual interface, the calibrator measures pressure, temperature, and electrical signals.


Fluke 750SW DPCTrack2 Software

Create procedures, instructions, and action lists to deliver fast, easy documentation with this DCPTrack2 software. Compatible with the Fluke 753, 754, 743, and 744.

What's included with the Fluke FLUKE-754/750SW BU


  • Stackable Test Leads
  • Test Probes
  • Alligator Clips
  • Hook Clips
  • Battery Pack
  • Charger
  • HART Communication Cable
  • Carrying Case

Click on a category to view a selection of compatible accessories with the Fluke FLUKE-754/750SW BU Documenting Process Calibrator and DPC/TRACK2 Software Bundle.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke FLUKE-754/750SW BU Documenting Process Calibrator and DPC/TRACK2 Software Bundle

Customer Reviews for the Fluke FLUKE-754/750SW BU

Fluke FLUKE-754/750SW BU Offers



The Fluke 754/750SW BU Documenting Process Calibrator with Hart communication and DPC/TRACK2 software kit provides full control over system management. The kit includes the necessary clips to accommodate any circuit setup. The included accessories allow for full functionality and easy transportation of the kit around the workplace.

Features

  • Several clip types to accommodate different systems
  • Communication cable improves connection to compatible systems
  • Designed to troubleshoot HART connections and calibration

Fluke FLUKE-754/750SW BU Specifications


SoftwareDPC/TRACK2
CommunicationHart
Click here for complete specifications on the Fluke FLUKE-754/750SW BU

What is HART?

HART, the Highway Addressable Remote Transducer protocol, uses a 1200 baud Frequency Shift Keying (FSK) signal to superimpose digital information on the conventional 4 to 20 mA analog signal.

Why use the HART protocol?

HART is an industry standard developed to define the communications protocol between intelligent field devices and a control system, HART is the most widely used digital communication protocol in the process industry. More than five million HART field instruments are installed in more than 100,000 plants worldwide. The HART protocol:

  • Is supported by all of the major suppliers of process field instruments supported by the HART Communication Foundation, an industry-wide non-profit organization
  • Preserves present control strategies
  • Allows traditional 4 to 20 mA signals and digital communication to share the same two-wire loops
  • Provides important information for installation and maintenance: Tag IDs, measured values, range and span data, product information and diagnostics
  • Reduces operation costs by making it easier to manage and fully utilize "smart" instrument network

Fluke 754 HART Documenting Process Calibrator:
Get HART-ability

Process plants have taken advantage of smart transmitters, the need for a new generation of calibrators has emerged - calibrators that can communicate via industry standard digital protocols. This process calibrator combines HART communication capability in a documenting process calibrator to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART instrumentation. This process calibrator offers:

  • Integrated HART communication functions, permitting you to monitor, control, and calibrate HART instrumentation
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 mS
  • Li-ion battery with 4400 mA hour life and gas gauge
Fluke 754 Documenting Process Calibrator With HART Communication

The field calibrator for HART instruments that's both powerful and easy to use

This process calibrator offers the most complete HART implementation of any process calibrator. This process calibrator:

  • Requires no external box or second tool for everyday HART calibration and maintenance
  • Offers fast HART communication
  • Supports popular models of HART transmitters with device-specific command support
  • Fully complies with the Data Link Layer of the HART protocol, including multiple masters, burst mode, and multi-drop configurations
  • Is easy to update as additional instruments are added and new HART versions are released
  • Is based on the 740 series calibrators, the most rugged, reliable multifunction field calibrators ever made
  • Is backed by the service and support of the Fluke organization, a member of the HART Communications Foundation

This process calibrator is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers many of the communication capabilities of the 475 HART communicator except for the DD interpreter, which can read command set libraries from any HART supplier. This is not necessary for daily HART maintenance.


How to calibrate a HART smart pressure transmitter

Calibrating a HART Smart Pressure Transmitter

Pressure transmitter manufacturers have improved the accuracy and technology designed into these smart pressure measurement devices. Many conventional calibration tools have become inadequate or simply unable to test and calibrate these high accuracy pressure transmitters. Better test solutions are required.

Verifying and documenting the performance and adjusting a HART smart pressure transmitter can require a bucket full of tools. Performing this task with a HART enabled calibrator like this process calibrator simplifies the task and reduces what you need to carry.

Before going to the field, install the pressure module adapter to the hand pump with thread seal. Once the adapter is properly installed on the pump, changing modules to different pressure ranges is a snap, no tools required.

To get the accuracy needed to test these new high accuracy transmitters, match the pressure measurement standard range closely to the device tested. For example, use a 100 psi pressure module to calibrate and test a transmitter ranged at 100 psi. Industry standards suggest the measurement standard should be 4 to 10 times more accurate than the device being tested, so best-in-class accuracy is required.

This Documenting Process Calibrator-HART utilizes the 750P series pressure module and has the HART functionality built in to enable smart trims on transmitters. It can also document transmitter performance before and after adjustment and calculate pass/fail errors.

To perform the test:

  1. Isolate the transmitter from the process being measure and its loop wiring. If measuring the mA signal across the transmitter test diode leave the wires intact, but note this method does not give the best mA measurement accuracy.
  2. Connect the mA measurement jacks of this process calibrator to the transmitter.
  3. Connect the pressure module cable to this process calibrator and connect the transmitter test hose from the hand pump to the transmitter.
  4. Press the HART button on the calibrator to see the configuration of the transmitter.
  5. Press HART again and the calibrator will offer the correct measure/source combination for the test. If documenting the calibration press As-Found, input the test tolerance and follow the prompts. If the measured mA signal at the test points is found within tolerance the test is complete. If not, adjustment is required.
  6. Select, adjust, and trim the pressure zero, mA output signal and input sensor.
  7. After adjustment select As-Left, document the condition of the transmitter and after adjustment and if the test passes, it is complete.

HART applications

Fluke 754: The HART calibrator that is easy to use.
Versatile HART protocol support

This process calibrator supports the commands contained in HART protocol version 5.7.
This process calibrator supports a substantial set of HART instructions:

  • Universal commands - provide functions that are implemented in all field devices, for example, read manufacturer and device type, read primary variable (PV), or read current output and percent of span
  • Common practice commands - provide functions that are common to many but not all field devices, for example read multiple variables, set damping time, or perform loop test
  • Device-specific commands - provide functions that are unique to a particular field device, for example sensor trim

Today's 754 supports device-specific instructions for a variety of popular instruments. Additional support may be added periodically with a simple software update available on diskette or via download for a modest upgrade fee.

Manufacturer Pressure Instruments Temperature Instruments Coriolis Instruments
ABB/Kent-Taylor 600T 658T1
ABB/Hartmann & Braun Contrans P1, AS 800 Series
Endress & Hauser CERABAR S, CERABAR M, DELTABAR S TMT 1221, TMT 1821, TMT 1621
Foxboro Eckardt TI/RTT201
Foxboro/Invensys I/A Pressure
Fuji FCX, FCXAZ FRC
Honeywell ST3000 STT25T1, STT25H1
Micro Motion 2000, 2000IS, 9701, 9712, 9739
Moore Products 3441
Rosemount 1151, 2088, 3001C, 3051, 3051S 3044C, 644, 3144, 3244, 3144P
Siemens SITRANS P DS
SMAR SITRANS P DS, SITRANS P ES
Viatran LD301 TT3011
Wika UNITRANS
Yokogawa EJA YTA 110, 310 and 320

1Sensor trim not supported

Fluke 754 Documenting Process Calibrator

HART Operating Modes Supported

  • For Point to Point operation, the most commonly used mode, connects this process calibrator to a single HART device in a 4 to 20 mA loop.
  • In Multi-Drop mode, several HART instruments can be bussed together. This process calibrator searches for each, identifies addresses in use, and allows you to select the instrument for calibration and related operations.
  • In Burst Mode, the HART instrument transmits bursts of data without waiting to be interrogated by a master unit. This process calibrator can take transmitters out of burst mode during test or calibration, then later restore them to burst mode.

This Fluke FLUKE-754/750SW BU Documenting Process Calibrator and DPC/TRACK2 Software Bundle Includes


Fluke 754 Documenting Process Calibrator with HART communication

Rugged and compact, this documenting process calibrator is powerful yet easy to use. Ideal for troubleshooting HART instrumentation, the calibrator offers communication and calibration functions in one tool. With a bright display and multi-lingual interface, the calibrator measures pressure, temperature, and electrical signals.


Fluke 750SW DPCTrack2 Software

Create procedures, instructions, and action lists to deliver fast, easy documentation with this DCPTrack2 software. Compatible with the Fluke 753, 754, 743, and 744.

What's included with the Fluke FLUKE-754/750SW BU


  • Stackable Test Leads
  • Test Probes
  • Alligator Clips
  • Hook Clips
  • Battery Pack
  • Charger
  • HART Communication Cable
  • Carrying Case

Click on a category to view a selection of compatible accessories with the Fluke FLUKE-754/750SW BU Documenting Process Calibrator and DPC/TRACK2 Software Bundle.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke FLUKE-754/750SW BU Documenting Process Calibrator and DPC/TRACK2 Software Bundle

Customer Reviews for the Fluke FLUKE-754/750SW BU

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.
Calibration Lab