Fluke 743B Documenting Process Calibrator

Model: 743B

Fluke 743B Documenting Process Calibrator

Model: 743B

300V DC, 110mADC. Source: 15V DC, 22mA DC.

300V DC, 110mADC. Source: 15V DC, 22mA DC.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Fluke 753 Documenting Process Calibrator-

Fluke 753 Documenting Process Calibrator

Model: 753

Equipped with a USB interface and communication cable, this process calibrator can source, simulate, and measure pressure, temperature, and electrical signals. Users can download procedures, lists, and instructions created with software, and even upload data for printing, archiving, and analysis.


Fluke 743B Specifications

Measurement Accuracy
Voltage DC
110.000 mV0.025%+0.015% *
1.10000 V0.025%+0.005% *
11.0000 V0.025%+0.005% *
110.000 V0.05%+0.005% *
300.00 V0.05%+0.005% *
Voltage AC
20 to 40 Hz2% + 10
40 to 500 Hz0.5% + 5
500 to 1 kHz2% + 10
1 kHz to 5 kHz10% + 20
Ranges1.1000, 11.000, 110.00, 300V
Current DC
30.000 mA0.01% + 0.015% *
110.00 mA0.01% + 0.015% *
Resistance
11.000 Ω0.05% + 50 mΩ
110.00 Ω0.05% + 50 mΩ
1.1000 kΩ0.05% + 500 mΩ
11.000 kΩ0.1% + 10 Ω
Frequency
1.00 to 109.99 Hz0.05 Hz
110.0 to 1099.9 Hz0.5 Hz
1.100 to 10.999 kHz5 Hz
11.00 to 50.00 kHz50 Hz
Pressure
Accuracyfrom 0.025% of range using any of 29 pressure modules.

(for detailed specifications refer to pressure modules in options and accessories)

Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Note
*(% of reading + % of full scale)

Source Accuracy
Voltage DC
110.000 mV0.01%+0.005% *
1.10000 V0.01%+0.005% *
15.0000 V0.01%+0.005% *
Current DC
22.000 mA (Source)0.01%+ 0.015% *
22.000 mA (Simulate)0.02% + 0.03% *
Resistance
11.000 Ω0.01% + 20 mΩ
110.00 Ω0.01% + 40 mΩ
1.1000 kΩ0.02% + 500 mΩ
11.000 kΩ0.03% + 5Ω
Frequency
0.00 to 10.99 Hz0.01 Hz
11.00 to 109.99 Hz0.1 Hz
110.0 to 1099.9 Hz0.1 Hz
1100 to 21999 Hz2 Hz
22.000 to 50.000 kHz5 Hz
Note
*(% of reading + % of full scale)

RTDs and Thermocouples
Measure Accuracy
10 Ω Cu (427): 2 °C
100 Ω Pt (3916)0.3 °C
100 Ω Pt (3926)0.3 °C
100 Ω Pt (385)0.3 °C
200 Ω Pt (385)0.3 °C
500 Ω Pt (385)0.3 °C
1000 Ω Pt (385)0.3 °C
120 Ω Ni (672)0.3 °C
noteFor 2-and 3-wire measurement, add 0.4 °C
E0.3 °C
N0.5 °C
J0.3 °C
L0.3 °C
K0.3 °C
T0.3 °C
U0.3 °C
B0.9 °C
R1.0 °C
S0.9 °C
C0.6 °C
noteAccuracy with external cold junction, for internal junction add 0.2 °C
Source Accuracy:
10 Ω Cu (427)1 °C
100 Ω Pt (3916)0.1°C
100 Ω Pt (3926)0.1°C
100 Ω Pt (385)0.1°C
200 Ω Pt (385)0.1°C
500 Ω Pt (385)0.1°C
1000 Ω Pt (385)0.1°C
120 Ω Ni (672)0.1°C
noteFor 2-and 3-wire simulation, add 0.4 °C
E0.2 °C
N0.3 °C
J0.2 °C
L0.2 °C
K0.3 °C
T0.3 °C
U0.3 °C
B0.8 °C
R0.9 °C
S0.9 °C
C0.6 °C
noteAccuracy with external cold junction, for internal junction add 0.2 °C

Specifications
Data Log Functions
Measure functionsVoltage, current, resistance, frequency, temperature, pressure
Reading rate1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions
Source functionsVoltage, current, resistance, frequency, temperature
Rate4 steps/second
Trip detectContinuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
VoltageSelectable, 24 V or 28 V
Accuracy5%
Maximum current22 mA, short circuit protected
Maximum input voltage30 V DC
Step Functions
Source FunctionsVoltage, current, resistance, frequency, temperature
Manual StepSelectable step, change with arrow buttons
AutostepFully programmable for function, start delay, stepvalue, time per step, repeat

Environmental Specifications
Operating temperature

-10°C to +50°C

-20°C to +50°C *
Storage temperature

-20°C to +60°C
Dust/water resistance

Meets IP52, IEC 529
Operating Altitude

2800 m
Note
*Except frequency and AC

Safety Specifications
Agency Approvals

CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993

Mechanical & General Specifications
Size

130 x 236 x 61 mm
Weight

1.4 kg
Batteries
NiCd7.2V, 1.7 Ah
Battery life

~8 hours typical
Battery Replacement

Via snap-shut door without opening calibrator; no tools required
Side port connections

Pressure module connector

RS-232 connector for PC interface cable

Connection for optional battery eliminator
Data storage capacity

1 week of calibration results
90 day specifications

The standard specification intervals for the 743B is 1 and 2 years.

Typical 90 day measurement and source accuracy can be estimated by

dividing the one year "% of reading" or "%of output" specifications by 2.

Floor specifications, expressed as "% of full scale" or

"counts" or "ohms" remain constant.

What's included with the Fluke 743B

  • Fluke 743B Documenting Process Calibrator

Click on a category to view a selection of compatible accessories with the Fluke 743B Documenting Process Calibrator.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 743B Documenting Process Calibrator

Customer Reviews for the Fluke 743B

Fluke 743B Specifications

Measurement Accuracy
Voltage DC
110.000 mV0.025%+0.015% *
1.10000 V0.025%+0.005% *
11.0000 V0.025%+0.005% *
110.000 V0.05%+0.005% *
300.00 V0.05%+0.005% *
Voltage AC
20 to 40 Hz2% + 10
40 to 500 Hz0.5% + 5
500 to 1 kHz2% + 10
1 kHz to 5 kHz10% + 20
Ranges1.1000, 11.000, 110.00, 300V
Current DC
30.000 mA0.01% + 0.015% *
110.00 mA0.01% + 0.015% *
Resistance
11.000 Ω0.05% + 50 mΩ
110.00 Ω0.05% + 50 mΩ
1.1000 kΩ0.05% + 500 mΩ
11.000 kΩ0.1% + 10 Ω
Frequency
1.00 to 109.99 Hz0.05 Hz
110.0 to 1099.9 Hz0.5 Hz
1.100 to 10.999 kHz5 Hz
11.00 to 50.00 kHz50 Hz
Pressure
Accuracyfrom 0.025% of range using any of 29 pressure modules.

(for detailed specifications refer to pressure modules in options and accessories)

Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Note
*(% of reading + % of full scale)

Source Accuracy
Voltage DC
110.000 mV0.01%+0.005% *
1.10000 V0.01%+0.005% *
15.0000 V0.01%+0.005% *
Current DC
22.000 mA (Source)0.01%+ 0.015% *
22.000 mA (Simulate)0.02% + 0.03% *
Resistance
11.000 Ω0.01% + 20 mΩ
110.00 Ω0.01% + 40 mΩ
1.1000 kΩ0.02% + 500 mΩ
11.000 kΩ0.03% + 5Ω
Frequency
0.00 to 10.99 Hz0.01 Hz
11.00 to 109.99 Hz0.1 Hz
110.0 to 1099.9 Hz0.1 Hz
1100 to 21999 Hz2 Hz
22.000 to 50.000 kHz5 Hz
Note
*(% of reading + % of full scale)

RTDs and Thermocouples
Measure Accuracy
10 Ω Cu (427): 2 °C
100 Ω Pt (3916)0.3 °C
100 Ω Pt (3926)0.3 °C
100 Ω Pt (385)0.3 °C
200 Ω Pt (385)0.3 °C
500 Ω Pt (385)0.3 °C
1000 Ω Pt (385)0.3 °C
120 Ω Ni (672)0.3 °C
noteFor 2-and 3-wire measurement, add 0.4 °C
E0.3 °C
N0.5 °C
J0.3 °C
L0.3 °C
K0.3 °C
T0.3 °C
U0.3 °C
B0.9 °C
R1.0 °C
S0.9 °C
C0.6 °C
noteAccuracy with external cold junction, for internal junction add 0.2 °C
Source Accuracy:
10 Ω Cu (427)1 °C
100 Ω Pt (3916)0.1°C
100 Ω Pt (3926)0.1°C
100 Ω Pt (385)0.1°C
200 Ω Pt (385)0.1°C
500 Ω Pt (385)0.1°C
1000 Ω Pt (385)0.1°C
120 Ω Ni (672)0.1°C
noteFor 2-and 3-wire simulation, add 0.4 °C
E0.2 °C
N0.3 °C
J0.2 °C
L0.2 °C
K0.3 °C
T0.3 °C
U0.3 °C
B0.8 °C
R0.9 °C
S0.9 °C
C0.6 °C
noteAccuracy with external cold junction, for internal junction add 0.2 °C

Specifications
Data Log Functions
Measure functionsVoltage, current, resistance, frequency, temperature, pressure
Reading rate1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions
Source functionsVoltage, current, resistance, frequency, temperature
Rate4 steps/second
Trip detectContinuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
VoltageSelectable, 24 V or 28 V
Accuracy5%
Maximum current22 mA, short circuit protected
Maximum input voltage30 V DC
Step Functions
Source FunctionsVoltage, current, resistance, frequency, temperature
Manual StepSelectable step, change with arrow buttons
AutostepFully programmable for function, start delay, stepvalue, time per step, repeat

Environmental Specifications
Operating temperature

-10°C to +50°C

-20°C to +50°C *
Storage temperature

-20°C to +60°C
Dust/water resistance

Meets IP52, IEC 529
Operating Altitude

2800 m
Note
*Except frequency and AC

Safety Specifications
Agency Approvals

CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993

Mechanical & General Specifications
Size

130 x 236 x 61 mm
Weight

1.4 kg
Batteries
NiCd7.2V, 1.7 Ah
Battery life

~8 hours typical
Battery Replacement

Via snap-shut door without opening calibrator; no tools required
Side port connections

Pressure module connector

RS-232 connector for PC interface cable

Connection for optional battery eliminator
Data storage capacity

1 week of calibration results
90 day specifications

The standard specification intervals for the 743B is 1 and 2 years.

Typical 90 day measurement and source accuracy can be estimated by

dividing the one year "% of reading" or "%of output" specifications by 2.

Floor specifications, expressed as "% of full scale" or

"counts" or "ohms" remain constant.

What's included with the Fluke 743B

  • Fluke 743B Documenting Process Calibrator

Click on a category to view a selection of compatible accessories with the Fluke 743B Documenting Process Calibrator.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 743B Documenting Process Calibrator

Customer Reviews for the Fluke 743B

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.
Calibration Lab