A single-use logger monitors temperature up to 90 days in as low as -328°F ( -200°C) using a built-in 1.5 m probe. The logger has a built-in alarm and can be configured using InTemp app with the preset or customized configurations.
A single-use logger monitors temperature up to 90 days in as low as -328°F ( -200°C) using a built-in 1.5 m probe. The logger has a built-in alarm and can be configured using InTemp app with the preset or customized configurations.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
The InTemp Cryogenic loggers features a built-in external probe designed for cold shipment monitoring. A protective sheath and clip are included to secure the logger and protect the probe cable. With the use of Bluetooth Low Energy, the logger wirelessly communicates to mobile devices with InTemp app. The web-based software InTempConnect provides a total wireless monitoring solution where you can configure the loggers and then download them to share and view logger reports, which include logged data, excursions, and alarm information.
Features
Applications
This data logger operates in a cold chain environment.
Sensor Range | -328 to 122°F (-200 to 50°C) To ensure insulation integrity, avoid flexing the wire during exposure to temperatures below -148°F (-100°C) |
Accuracy | ±2.7°F from -328 to -130°F (±1.5°C from -200 to -90°C) ±1.8°F from -328 to 14°F (±1.0°C from -90 to -10°C) ±0.9°F from 14 to 122°F (±0.5°C from -10 to 50°C) |
Resolution | 0.023° at 77°F (0.013° at 25°C) |
NIST Calibration | Three-point NIST calibration, probe only |
Cable Length | 4.92' (1.5 m) |
Logger Operating Range | -22 to 122°F (-30 to 50°C) |
Radio Power | 1 mW (0 dBm) |
Transmission Range | Approximately 100' (30.5 m) line-of-sight |
Wireless Data Standard | Bluetooth Low Energy (Bluetooth Smart) |
Type | Single use |
Sensor Range | -328 to 122°F (-200 to 50°C) To ensure insulation integrity, avoid flexing the wire during exposure to temperatures below -148°F (-100°C) |
Accuracy | ±2.7°F from -328 to -130°F (±1.5°C from -200 to -90°C) ±1.8°F from -328 to 14°F (±1.0°C from -90 to -10°C) ±0.9°F from 14 to 122°F (±0.5°C from -10 to 50°C) |
Resolution | 0.023° at 77°F (0.013° at 25°C) |
NIST Calibration | Three-point NIST calibration, probe only |
Cable Length | 4.92' (1.5 m) |
Logger Operating Range | -22 to 122°F (-30 to 50°C) |
Radio Power | 1 mW (0 dBm) |
Transmission Range | Approximately 100' (30.5 m) line-of-sight |
Wireless Data Standard | Bluetooth Low Energy (Bluetooth Smart) |
Type | Single use |