Onset HOBO U26-001 Dissolved Oxygen Data Logger

Model: U26-001

Onset HOBO U26-001 Dissolved Oxygen Data Logger

Model: U26-001

Easy to maintain and measures oxygen concentrations in lakes, streams, rivers, estuaries, and coastal waters.

Easy to maintain and measures oxygen concentrations in lakes, streams, rivers, estuaries, and coastal waters.

Your Price $1395.00 USD
Availability 5 to 6 Weeks
Quantity
Choose between the following required accessories:

Communication

Choose any one of these options

Software

Choose between the following required accessories:

Communication

Choose any one of these options

Software


Onset HOBO U26-001 Offers

HOBO data loggers requires HOBOware software (USB interface cable included w/CD purchase) and a communications device. HOBOware Pro is required when using the U-DTW-1 Waterproof shuttle. For DO measurements in saltwater, an adjustment for salinity is required. For waters with small changes in salinity (<2 ppt), a salinity meter reading typically provides enough accuracy.

Features

  • Optical DO sensor technology for long-lasting calibration with less maintenance
  • HOBOware Pro's Dissolved Oxygen Assistant software corrects for measurement drift from fouling; provides salinity-adjusted DO concentrations and percent saturation
  • Optical USB interface for high-speed, reliable data offload
  • Easy-to-replace DO sensor cap lasts six months

Applications

  • Aquatic biology
  • Hydrology research projects

Supported Measurements

  • Dissolved Oxygen
  • Temperature

HOBOware

With the latest version of software (HOBOware 3.7.8), Optic Base Station and Waterproof Shuttle users will find much-improved communications methods.

For Mac users - Updating to apple's latest operating system (OS X 10.11.5) will remedy any communications issues you might have encountered with the HOBO U30 Weather Station and the Waterproof Shuttle.

HOBOmobile

HOBOmobile 1.5 for iOS can now push data to HOBOlink.com for free online data storage.

Download the Mobile App

HOBO Data Loggers U26-001 Specifications

Dissolved Oxygen
Sensor Type Optical
Measurement Range 0 to 30 mg/L
Calibrated Range 0 to 20 mg/L; 32 to 95°F (0 to 35°C)
Accuracy 0.2 mg/L up to 8 mg/L; 0.5 mg/L from 8 to 20 mg/L
Resolution 0.02 mg/L
Temperature
Operation rang 23 to 104°F (-5 to 40°C); non-Freezing
Accuracy 0.36°F (0.2°C)
Resolution 0.04°F (0.02°C)
Response Time To 90% in less than 30 minutes
Logger
Memory 21,700 sets of DO and temperature measurements (64 KB total memory)
Logging Rate 1 minute to 18 hours
Click here for complete specifications on the Onset HOBO U26-001

What's included with the HOBO Data Loggers U26-001

  • Dissolved Oxygen Data Logger
  • DO sensor cap
  • Protective Guard
  • Calibration Boot with sponge

HOBO U26 Demonstrates Accuracy and Reliability

The Alliance for Coastal Technologies (ACT) has released an independent verification study of Onset’s HOBO® U26 Dissolved Oxygen Logger as part of a multi-year evaluation of in situ dissolved oxygen (DO) sensors. Conducted during 2015-2016, the unbiased verification characterized performance measures of accuracy and reliability in a series of controlled laboratory studies and field mooring tests in diverse coastal environments.

The HOBO U26—one of two stand-alone DO loggers in the study —performed well in these tests, demonstrating high accuracy over a wide range of DO, temperature, and salinity conditions. The HOBO U26 also successfully maintained its accuracy over a long-term (56 days) lab testing period.

The verification included several months of laboratory testing and three field deployments in freshwater, estuarine, and oceanic environments. Instrument accuracy and precision for the HOBO U26 was tested under nine combinations of temperature and salinity over a range of DO concentrations from 10% to 120% of saturation.

Results indicated that the HOBO U26 operated reliably throughout these challenging tests. The ACT study also found that the response of the HOBO U26 RDO sensor showed good linearity during field testing across freshwater, brackish water, and oceanic water salinity ranges.

“We are very pleased to see the HOBO Dissolved Oxygen Logger perform so well in this independent study, especially considering the HOBO is a fraction of the cost of most of the other DO logging systems,” said Paul Gannett, Onset product marketing manager.

The field tests confirmed the importance of keeping the sensor clean in high-fouling environments. Onset recommends regular cleaning to remove fouling to maintain the performance of the HOBO U26, as well as using field calibration to achieve the best accuracy and compensate for measurement drift from fouling.

Overall, the ACT results confirm the high performance and reliability of the HOBO U26, available at a lower cost than other high-end oceanographic systems.

Click on a category to view a selection of compatible accessories with the Onset HOBO U26-001 Dissolved Oxygen Data Logger.

Onset HOBO BASE-U-4 Universal Optic USB Base Station BASE-U-4
Use the base station with included couplers to offload your data from any HOBO® data logger with an optic USB interface.




Onset HOBO U-DTW-1 Waterproof Shuttle and Base Station U-DTW-1
Provides convenient readout and relaunching of underwater and outdoor HOBO data loggers with an optic USB interface. Can also be used as a base station. Waterproof to 20m (66').




Onset HOBO BHW-PRO-USB Onset HOBOware Pro Software Compatible with Mac and Windows BHW-PRO-USB
Simple and easy to use point and click interface. This software is compatible with all HOBO data loggers and wireless data nodes. USB Cable included.




Onset HOBO U26-RDOB-1 Replacement DO Sensor Cap U26-RDOB-1
Replaces the original DO sensor cap included with the HOBO DO Data Logger. The sensor caps have a 6-month deployment life. The caps expire 7 months after initialization to allow some time before and after the deployment. The caps have a 2-year shelf-life from the date they were manufactured. Shelf-life shown on the canisters the caps come in.




Onset HOBO U26-CAL-SOL Sodium Sulfite Solution, 500 mL U26-CAL-SOL
Needed to calibrate the HOBO Dissolved Oxygen Logger at 0% saturation. Calibrating the unit is optional.




Onset HOBO COUPLER2-C Replacement Coupler COUPLER2-C
For use with U20L, U22, U24, and U26 data loggers.




Onset HOBO U26-GUARD-2 Antifouling Protective Guard U26-GUARD-2
Can be used in place of the standard protective guard for protection against fouling during deployment. The anti-fouling guard uses copper windings to reduce bio-fouling and still allows a good water flow to the sensor.




Ask a question about Onset HOBO U26-001 Dissolved Oxygen Data Logger

Customer Reviews for the Onset HOBO U26-001

Onset HOBO U26-001 Offers

HOBO data loggers requires HOBOware software (USB interface cable included w/CD purchase) and a communications device. HOBOware Pro is required when using the U-DTW-1 Waterproof shuttle. For DO measurements in saltwater, an adjustment for salinity is required. For waters with small changes in salinity (<2 ppt), a salinity meter reading typically provides enough accuracy.

Features

  • Optical DO sensor technology for long-lasting calibration with less maintenance
  • HOBOware Pro's Dissolved Oxygen Assistant software corrects for measurement drift from fouling; provides salinity-adjusted DO concentrations and percent saturation
  • Optical USB interface for high-speed, reliable data offload
  • Easy-to-replace DO sensor cap lasts six months

Applications

  • Aquatic biology
  • Hydrology research projects

Supported Measurements

  • Dissolved Oxygen
  • Temperature

HOBOware

With the latest version of software (HOBOware 3.7.8), Optic Base Station and Waterproof Shuttle users will find much-improved communications methods.

For Mac users - Updating to apple's latest operating system (OS X 10.11.5) will remedy any communications issues you might have encountered with the HOBO U30 Weather Station and the Waterproof Shuttle.

HOBOmobile

HOBOmobile 1.5 for iOS can now push data to HOBOlink.com for free online data storage.

Download the Mobile App

HOBO Data Loggers U26-001 Specifications

Dissolved Oxygen
Sensor Type Optical
Measurement Range 0 to 30 mg/L
Calibrated Range 0 to 20 mg/L; 32 to 95°F (0 to 35°C)
Accuracy 0.2 mg/L up to 8 mg/L; 0.5 mg/L from 8 to 20 mg/L
Resolution 0.02 mg/L
Temperature
Operation rang 23 to 104°F (-5 to 40°C); non-Freezing
Accuracy 0.36°F (0.2°C)
Resolution 0.04°F (0.02°C)
Response Time To 90% in less than 30 minutes
Logger
Memory 21,700 sets of DO and temperature measurements (64 KB total memory)
Logging Rate 1 minute to 18 hours
Click here for complete specifications on the Onset HOBO U26-001

What's included with the HOBO Data Loggers U26-001

  • Dissolved Oxygen Data Logger
  • DO sensor cap
  • Protective Guard
  • Calibration Boot with sponge

HOBO U26 Demonstrates Accuracy and Reliability

The Alliance for Coastal Technologies (ACT) has released an independent verification study of Onset’s HOBO® U26 Dissolved Oxygen Logger as part of a multi-year evaluation of in situ dissolved oxygen (DO) sensors. Conducted during 2015-2016, the unbiased verification characterized performance measures of accuracy and reliability in a series of controlled laboratory studies and field mooring tests in diverse coastal environments.

The HOBO U26—one of two stand-alone DO loggers in the study —performed well in these tests, demonstrating high accuracy over a wide range of DO, temperature, and salinity conditions. The HOBO U26 also successfully maintained its accuracy over a long-term (56 days) lab testing period.

The verification included several months of laboratory testing and three field deployments in freshwater, estuarine, and oceanic environments. Instrument accuracy and precision for the HOBO U26 was tested under nine combinations of temperature and salinity over a range of DO concentrations from 10% to 120% of saturation.

Results indicated that the HOBO U26 operated reliably throughout these challenging tests. The ACT study also found that the response of the HOBO U26 RDO sensor showed good linearity during field testing across freshwater, brackish water, and oceanic water salinity ranges.

“We are very pleased to see the HOBO Dissolved Oxygen Logger perform so well in this independent study, especially considering the HOBO is a fraction of the cost of most of the other DO logging systems,” said Paul Gannett, Onset product marketing manager.

The field tests confirmed the importance of keeping the sensor clean in high-fouling environments. Onset recommends regular cleaning to remove fouling to maintain the performance of the HOBO U26, as well as using field calibration to achieve the best accuracy and compensate for measurement drift from fouling.

Overall, the ACT results confirm the high performance and reliability of the HOBO U26, available at a lower cost than other high-end oceanographic systems.

Click on a category to view a selection of compatible accessories with the Onset HOBO U26-001 Dissolved Oxygen Data Logger.

Onset HOBO BASE-U-4 Universal Optic USB Base Station BASE-U-4
Use the base station with included couplers to offload your data from any HOBO® data logger with an optic USB interface.




Onset HOBO U-DTW-1 Waterproof Shuttle and Base Station U-DTW-1
Provides convenient readout and relaunching of underwater and outdoor HOBO data loggers with an optic USB interface. Can also be used as a base station. Waterproof to 20m (66').




Onset HOBO BHW-PRO-USB Onset HOBOware Pro Software Compatible with Mac and Windows BHW-PRO-USB
Simple and easy to use point and click interface. This software is compatible with all HOBO data loggers and wireless data nodes. USB Cable included.




Onset HOBO U26-RDOB-1 Replacement DO Sensor Cap U26-RDOB-1
Replaces the original DO sensor cap included with the HOBO DO Data Logger. The sensor caps have a 6-month deployment life. The caps expire 7 months after initialization to allow some time before and after the deployment. The caps have a 2-year shelf-life from the date they were manufactured. Shelf-life shown on the canisters the caps come in.




Onset HOBO U26-CAL-SOL Sodium Sulfite Solution, 500 mL U26-CAL-SOL
Needed to calibrate the HOBO Dissolved Oxygen Logger at 0% saturation. Calibrating the unit is optional.




Onset HOBO COUPLER2-C Replacement Coupler COUPLER2-C
For use with U20L, U22, U24, and U26 data loggers.




Onset HOBO U26-GUARD-2 Antifouling Protective Guard U26-GUARD-2
Can be used in place of the standard protective guard for protection against fouling during deployment. The anti-fouling guard uses copper windings to reduce bio-fouling and still allows a good water flow to the sensor.




Ask a question about Onset HOBO U26-001 Dissolved Oxygen Data Logger