Get high-accuracy water level/depth measurements with this pressure sensor that works with the RX3000 cellular weather station to bring your water level data to the web. In addition, this sensor is suitable for a wide range of level monitoring applications and has a power requirement of 9 to 30 VDC.
Get high-accuracy water level/depth measurements with this pressure sensor that works with the RX3000 cellular weather station to bring your water level data to the web. In addition, this sensor is suitable for a wide range of level monitoring applications and has a power requirement of 9 to 30 VDC.
Features
Applications
Power Requirements | 9 to 30 V DC |
Output | 4 to 20 mA current signal, linearly corresponding to range |
Temperature | Operating: -40 to 185°F (-40 to 85°C) Compensated: 32 to 122°F (0 to 50°C) |
Linearity | 0 to 5' (0 to 1.5 m) range: 0.2% maximum 0 to 10' (0 to 3 m) range: 0.2% maximum 0 to 35' (0 to 10.7 m) range: 0.3% maximum 0 to 50' (0 to 15.2 m) range: 0.3% maximum (0.1% typical for all ranges) |
Repeatability and Hysteresis | Typical: ±0.2% span |
Reverse Polarity Protection | Built into sensor |
Overpressure | 0 to 5' (0 to 1.5 m): 20 psi maximum 0 to 10' (0 to 3 m): 20 psi maximum 0 to 35' (0 to 10.7 m): 45 psi maximum 0 to 50' (0 to 15.2 m): 45 psi maximum |
Shock | Qualification tested to 5.29 oz (150 g) |
Wiring | Red: Power Green: 4 to 20 mA return Silver: Drain wire |
Pipe Threading | ½ to 14 straight pipe thread (back of sensor housing near cable) ⅜ to 18 straight pipe thread (under removable copper nose-cone) |
Dimensions | 4 x 0.84" (101.6 x 21.33 mm) |
Weight | Probe: 2.37 oz (61.19 g) Cable: 0.43 oz (12.19 g) per foot (0.4 g per cm) Weights are approximate |
Power Requirements | 9 to 30 V DC |
Output | 4 to 20 mA current signal, linearly corresponding to range |
Temperature | Operating: -40 to 185°F (-40 to 85°C) Compensated: 32 to 122°F (0 to 50°C) |
Linearity | 0 to 5' (0 to 1.5 m) range: 0.2% maximum 0 to 10' (0 to 3 m) range: 0.2% maximum 0 to 35' (0 to 10.7 m) range: 0.3% maximum 0 to 50' (0 to 15.2 m) range: 0.3% maximum (0.1% typical for all ranges) |
Repeatability and Hysteresis | Typical: ±0.2% span |
Reverse Polarity Protection | Built into sensor |
Overpressure | 0 to 5' (0 to 1.5 m): 20 psi maximum 0 to 10' (0 to 3 m): 20 psi maximum 0 to 35' (0 to 10.7 m): 45 psi maximum 0 to 50' (0 to 15.2 m): 45 psi maximum |
Shock | Qualification tested to 5.29 oz (150 g) |
Wiring | Red: Power Green: 4 to 20 mA return Silver: Drain wire |
Pipe Threading | ½ to 14 straight pipe thread (back of sensor housing near cable) ⅜ to 18 straight pipe thread (under removable copper nose-cone) |
Dimensions | 4 x 0.84" (101.6 x 21.33 mm) |
Weight | Probe: 2.37 oz (61.19 g) Cable: 0.43 oz (12.19 g) per foot (0.4 g per cm) Weights are approximate |