Loaded with numerous functions, this compact power controller has a maximum load capacity of 30 A AC and an input signal of 4 to 20 mA DC. In addition, it features a space-saving design and offers excellent response and reproducibility.
Loaded with numerous functions, this compact power controller has a maximum load capacity of 30 A AC and an input signal of 4 to 20 mA DC. In addition, it features a space-saving design and offers excellent response and reproducibility.
Single phase power controller has an LED display to show set values and input signals and front keys for easy setting and monitoring. Loaded with versatile standard functions, this power controller operates at 100 up to 240 V AC and automatically selects power supply frequency 50 or 60 Hz.
Features
Applications
Load Current | Maximum: 30 A AC Minimum: 1 A |
Control Method | Phase control |
Applicable Load | Linearity (R:Resistor) load Inductive load (When phase control: Control of primary side of a transformer, magnetic field density 1.25T or less) |
Input Signal | Current input 4 to 20 mA DC (Input impedance: 100 Ω) Voltage input 1 to 5V DC (Input impedance: 30 kΩ) Voltage pulse input 0/12 V DC (Input impedance: 30 kΩ) Non-voltage contact input (Input impedance: 47 Ω) |
Output Voltage Range | 0 to 98% of rated voltage |
Power | Supply voltage: 90 to 264 V AC (Including power supply voltage variation) [Rating: 100 to 240 V DC] Frequency: 50/60 Hz (Automatic discriminating) |
Allowable | Power frequency variation: ±1 Hz (Performance guarantee range); ±2 Hz (Operating guarantee range) Ambient temperature: Performance guarantee: 0 to 40°C; Operating guarantee range: 5 to 131°F (-15 to 55°C) Ambient humidity: 5 to 95%RH (Non-condensing) |
Output Setting range | Gradient setting: 0.0 to 100% (Front key or external setting unit) Output limiter (High): 0.0 to 99.9% (Front key or external setting unit) Output limiter (Low): 0.0 to 99.9% (Front key or external setting unit) Base-up setting (Output bias): 0.0 to 99.9% (Front key) Manual setting: 0.0 to 99.9% (Front key) |
Output Mode | When phase control is selected for linearity load (R: resistor), output mode can be selected from Proportional phase angle to input, proportional voltage to input, and proportional square voltage (electric power) to input |
Cooling Method | Natural convection |
Dielectric Voltage | Between main circuit, power terminals and radiation fins: 2000 V AC for one minute |
Insulation Resistance | Between main circuit, power terminals and radiation fins: 20 M ohms or more (500 V DC) |
Mounting Method | Vertical |
Contents of Digital Display | Input signal value Phase angle ratio value Frequency value Control method Soft up/Soft down time Gradient set value Output limiter (High/Low) Base-up set value |
Compliance with Standards | UL Recognized |
Weight | Approximately 1.98 lbs (0.9 kg) |
Load Current | Maximum: 30 A AC Minimum: 1 A |
Control Method | Phase control |
Applicable Load | Linearity (R:Resistor) load Inductive load (When phase control: Control of primary side of a transformer, magnetic field density 1.25T or less) |
Input Signal | Current input 4 to 20 mA DC (Input impedance: 100 Ω) Voltage input 1 to 5V DC (Input impedance: 30 kΩ) Voltage pulse input 0/12 V DC (Input impedance: 30 kΩ) Non-voltage contact input (Input impedance: 47 Ω) |
Output Voltage Range | 0 to 98% of rated voltage |
Power | Supply voltage: 90 to 264 V AC (Including power supply voltage variation) [Rating: 100 to 240 V DC] Frequency: 50/60 Hz (Automatic discriminating) |
Allowable | Power frequency variation: ±1 Hz (Performance guarantee range); ±2 Hz (Operating guarantee range) Ambient temperature: Performance guarantee: 0 to 40°C; Operating guarantee range: 5 to 131°F (-15 to 55°C) Ambient humidity: 5 to 95%RH (Non-condensing) |
Output Setting range | Gradient setting: 0.0 to 100% (Front key or external setting unit) Output limiter (High): 0.0 to 99.9% (Front key or external setting unit) Output limiter (Low): 0.0 to 99.9% (Front key or external setting unit) Base-up setting (Output bias): 0.0 to 99.9% (Front key) Manual setting: 0.0 to 99.9% (Front key) |
Output Mode | When phase control is selected for linearity load (R: resistor), output mode can be selected from Proportional phase angle to input, proportional voltage to input, and proportional square voltage (electric power) to input |
Cooling Method | Natural convection |
Dielectric Voltage | Between main circuit, power terminals and radiation fins: 2000 V AC for one minute |
Insulation Resistance | Between main circuit, power terminals and radiation fins: 20 M ohms or more (500 V DC) |
Mounting Method | Vertical |
Contents of Digital Display | Input signal value Phase angle ratio value Frequency value Control method Soft up/Soft down time Gradient set value Output limiter (High/Low) Base-up set value |
Compliance with Standards | UL Recognized |
Weight | Approximately 1.98 lbs (0.9 kg) |