Accuenergy Acuvim II Series Advanced Power and Energy Meters

Accuenergy Acuvim II Series Advanced Power and Energy Meters

Work with a robust solution for power monitoring, kWh metering, power quality analysis, and more with these advanced power and energy meters. In addition, these meters are ideal for integration into any project environment, and an array of plug-in expansion modules facilitate communication on over 15 industry protocols.

Work with a robust solution for power monitoring, kWh metering, power quality analysis, and more with these advanced power and energy meters. In addition, these meters are ideal for integration into any project environment, and an array of plug-in expansion modules facilitate communication on over 15 industry protocols.

Configure This Product:

Model
Mounting Options
Current Input
Power Supply
To view your pricing & availability, choose your options and add this item to your cart.
Ordering Number
Work with a robust solution for power monitoring, kWh metering, power quality analysis, and more with these advanced power and energy meters. In addition, these meters are ideal for integration into any project environment, and an array of plug-in expansion modules facilitate communication on over 15 industry protocols.
Your Price $
Availability
Quantity

Accuenergy Acuvim II Series Offers

Features

  • Revenue grade with data logging
  • Waveform capture
  • Modbus, BACnet, SNMP
  • Level 2 DNP3 and IEC61850 2nd edition
  • MV90 support
  • 8GB data logging and event storage
  • COMtrade waveform format
  • Free cloud metering data storage + analytics

Applications

  • Submetering
  • Energy storage, microgrids, and VPPs
  • Power generation
  • Load banks
  • Building automation
  • PDUs and data centers
  • Energy management systems
  • Substation and distribution systems
  • Transformer monitoring
  • Measurement and verification

Accuenergy Acuvim II Series Specifications

Metering
Voltage Accuracy: 0.2%
Resolution: 0.1 V
Range: 10 V to 1000 kV
Current Accuracy: 0.2%
Resolution: 0.1 mA
Range: 5 mA to 50000 A
Power Accuracy: 0.2%
Resolution: 1 W
Range: -9999 to 9999 MW
Reactive Power Accuracy: 0.2%
Resolution: 1 var
Range: -9999 to 9999 Mvar
Apparent Power Accuracy: 0.2%
Resolution: 1 VA
Range: 0 to 9999 MVA
Power Demand Accuracy: 0.2%
Resolution: 1 W
Range: -9999 to 9999 MW
Reactive Power Demand Accuracy: 0.2%
Resolution: 1 var
Range: -9999 to 9999 Mvar
Apparent Power Demand Accuracy: 0.2%
Resolution: 1 VA
Range: 0 to 9999 MVA
Power Factor Accuracy: 0.2%
Resolution: 0.001
Range: -1.000 to 1.000
Frequency Accuracy: 0.02%
Resolution: 0.01 Hz
Range: 45 to 65 Hz (50 or 60 Hz type) 300 Hz to 500 Hz (400 Hz type)
Energy Primary accuracy: 0.2%, resolution: 0.1 kWh, Range: 0 to 99999999.9 kWh
Secondary accuracy: 0.2%, resolution: 0.001 kWh, Range: 0 to 999999.999 kWh
Reactive Energy Primary accuracy: 0.2%, resolution: 0.1 kvarh, range: 0 to 99999999.9 kvarh
Secondary accuracy: 0.2%, resolution: 0.001 kvarh, range: 0 to 999999.999 kvarh
Apparent Energy Primary accuracy: 0.2%, resolution: 0.1 kVAh, range: 0 to 99999999.9 kVAh
Secondary accuracy: 0.2%, resolution: 0.001 kVAh, range: 0 to 999999.999 kVAh
Harmonics Accuracy: 1.0%
Resolution: 0.1%
Phase Angle Accuracy: 2.0%
Resolution: 0.1°
Range: 0.0° to 359.9°
Unbalance Factor Accuracy: 2.0%
Resolution: 0.1%
Range: 0.0 to 100.0%
Running Time Resolution: 0.01 h
Range: 0 to 9999999.99 h
Current Inputs (Each Channel)
Nominal Current 1: 5 A
2: 1 A
3: 1 A (333 mV)
4: 1 A (100 mV Rope-CT)
5: 1 A (80 mA/100 mA/200 mA)
Metering Range 1: 0 to 10 A
2: 0 to 2 A
3: 0 to 1.2 A
4: 0 to 1.2 A
5: 0 to 1.2 A
Pickup Current 1: 5 mA
2: 1 mA
3: 5 mA
4: 5 mA
5: 5 mA
Withstand 20 Arms continuous, 0.1% of nominal
100 Arms for 1 second, non-recurring
Burden 0.05 VA (typical) at 5 Arms
Accuracy 0.2% full scale
Voltage Inputs (Each Channel)
Nominal Full Scale 400 V AC L to N, 690 V AC L-L (+20%)
Withstand 1500 V AC continuous
2500 V AC, 50/60 Hz for 1 minute
Input Impedence 2 MΩ per phase
Metering Frequency 45 to 65 Hz, 300 to 500 Hz
Pickup Voltage 10 V AC
Accuracy 0.2% full scale
Energy Accuracy
Active Class 0.2 second (according to IEC 62053-22)
Class 0.2 second (according to ANSI C12.20)
Reactive Class 2 (according to IEC 62053-23)
Harmonic Resolution
Metered Value 63rd harmonic (50 Hz or 60 Hz type)
15th harmonic (400 Hz type)
Digital Input
Input Voltage Range: 20 to 160 VAC/DC
Current (maximum): 2 mA
Voltage Start: 15 V
Stop: 5 V
Pulse Frequency (Maximum) 100 Hz, 50% duty ratio (5 ms ON and 5 ms OFF)
SOE Resolution 2 ms
Digital Output (DO) (Photo-Mos)
Voltage Range 0 to 250 VAC, 30 VDC
Load Current 5 A (R), 2 A (L)
Output Frequency 25 Hz, 50% Duty Ratio (20 ms ON, 20 ms OFF)
Isolation Voltage 2500 VAC
Relay Output (RO)
Switching Voltage (Maximum) 250 VAC, 30 VDC
Load Current 5 A (R), 2 A (L)
Set Time 10 ms (maximum)
Contact Resistance 30 mΩ (maximum)
Isolation Voltage 2500 VAC
Mechanical Life 1.5 x 10&supT;
Analog Output (AO)
Output Range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (sold separately)
Accuracy 0.5%
Temperature Drift 50 ppm/°C typical
Isolation Voltage 500 VDC
Open Circuit Voltage 15 V
Analog Input (AI)
Input Range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (sold separately)
Accuracy 0.5%
Temperature Drift 50 ppm/°C typical
Isolation Voltage 500 VDC
Power Supply for DI (24 VDC)
Output Voltage: 24 VDC
Current: 42 mA
Load (Maximum) 21 Dis
Operating Environment
Temperature Operation: -13 to 158°F (-25 to 70°C)
Storage: -40 to 185°F (-40 to 85°C)
Relative Humidity 5 to 95% non-condensing
Click here for complete specifications on the Accuenergy Acuvim II Series

What's included with the Accuenergy Acuvim II Series

  • Accuenergy Acuvim II Series Advanced Power and Energy Meters

Ask a question about Accuenergy Acuvim II Series Advanced Power and Energy Meters

Customer Reviews for the Accuenergy Acuvim II Series

Accuenergy Acuvim II Series Offers

Features

  • Revenue grade with data logging
  • Waveform capture
  • Modbus, BACnet, SNMP
  • Level 2 DNP3 and IEC61850 2nd edition
  • MV90 support
  • 8GB data logging and event storage
  • COMtrade waveform format
  • Free cloud metering data storage + analytics

Applications

  • Submetering
  • Energy storage, microgrids, and VPPs
  • Power generation
  • Load banks
  • Building automation
  • PDUs and data centers
  • Energy management systems
  • Substation and distribution systems
  • Transformer monitoring
  • Measurement and verification

Accuenergy Acuvim II Series Specifications

Metering
Voltage Accuracy: 0.2%
Resolution: 0.1 V
Range: 10 V to 1000 kV
Current Accuracy: 0.2%
Resolution: 0.1 mA
Range: 5 mA to 50000 A
Power Accuracy: 0.2%
Resolution: 1 W
Range: -9999 to 9999 MW
Reactive Power Accuracy: 0.2%
Resolution: 1 var
Range: -9999 to 9999 Mvar
Apparent Power Accuracy: 0.2%
Resolution: 1 VA
Range: 0 to 9999 MVA
Power Demand Accuracy: 0.2%
Resolution: 1 W
Range: -9999 to 9999 MW
Reactive Power Demand Accuracy: 0.2%
Resolution: 1 var
Range: -9999 to 9999 Mvar
Apparent Power Demand Accuracy: 0.2%
Resolution: 1 VA
Range: 0 to 9999 MVA
Power Factor Accuracy: 0.2%
Resolution: 0.001
Range: -1.000 to 1.000
Frequency Accuracy: 0.02%
Resolution: 0.01 Hz
Range: 45 to 65 Hz (50 or 60 Hz type) 300 Hz to 500 Hz (400 Hz type)
Energy Primary accuracy: 0.2%, resolution: 0.1 kWh, Range: 0 to 99999999.9 kWh
Secondary accuracy: 0.2%, resolution: 0.001 kWh, Range: 0 to 999999.999 kWh
Reactive Energy Primary accuracy: 0.2%, resolution: 0.1 kvarh, range: 0 to 99999999.9 kvarh
Secondary accuracy: 0.2%, resolution: 0.001 kvarh, range: 0 to 999999.999 kvarh
Apparent Energy Primary accuracy: 0.2%, resolution: 0.1 kVAh, range: 0 to 99999999.9 kVAh
Secondary accuracy: 0.2%, resolution: 0.001 kVAh, range: 0 to 999999.999 kVAh
Harmonics Accuracy: 1.0%
Resolution: 0.1%
Phase Angle Accuracy: 2.0%
Resolution: 0.1°
Range: 0.0° to 359.9°
Unbalance Factor Accuracy: 2.0%
Resolution: 0.1%
Range: 0.0 to 100.0%
Running Time Resolution: 0.01 h
Range: 0 to 9999999.99 h
Current Inputs (Each Channel)
Nominal Current 1: 5 A
2: 1 A
3: 1 A (333 mV)
4: 1 A (100 mV Rope-CT)
5: 1 A (80 mA/100 mA/200 mA)
Metering Range 1: 0 to 10 A
2: 0 to 2 A
3: 0 to 1.2 A
4: 0 to 1.2 A
5: 0 to 1.2 A
Pickup Current 1: 5 mA
2: 1 mA
3: 5 mA
4: 5 mA
5: 5 mA
Withstand 20 Arms continuous, 0.1% of nominal
100 Arms for 1 second, non-recurring
Burden 0.05 VA (typical) at 5 Arms
Accuracy 0.2% full scale
Voltage Inputs (Each Channel)
Nominal Full Scale 400 V AC L to N, 690 V AC L-L (+20%)
Withstand 1500 V AC continuous
2500 V AC, 50/60 Hz for 1 minute
Input Impedence 2 MΩ per phase
Metering Frequency 45 to 65 Hz, 300 to 500 Hz
Pickup Voltage 10 V AC
Accuracy 0.2% full scale
Energy Accuracy
Active Class 0.2 second (according to IEC 62053-22)
Class 0.2 second (according to ANSI C12.20)
Reactive Class 2 (according to IEC 62053-23)
Harmonic Resolution
Metered Value 63rd harmonic (50 Hz or 60 Hz type)
15th harmonic (400 Hz type)
Digital Input
Input Voltage Range: 20 to 160 VAC/DC
Current (maximum): 2 mA
Voltage Start: 15 V
Stop: 5 V
Pulse Frequency (Maximum) 100 Hz, 50% duty ratio (5 ms ON and 5 ms OFF)
SOE Resolution 2 ms
Digital Output (DO) (Photo-Mos)
Voltage Range 0 to 250 VAC, 30 VDC
Load Current 5 A (R), 2 A (L)
Output Frequency 25 Hz, 50% Duty Ratio (20 ms ON, 20 ms OFF)
Isolation Voltage 2500 VAC
Relay Output (RO)
Switching Voltage (Maximum) 250 VAC, 30 VDC
Load Current 5 A (R), 2 A (L)
Set Time 10 ms (maximum)
Contact Resistance 30 mΩ (maximum)
Isolation Voltage 2500 VAC
Mechanical Life 1.5 x 10&supT;
Analog Output (AO)
Output Range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (sold separately)
Accuracy 0.5%
Temperature Drift 50 ppm/°C typical
Isolation Voltage 500 VDC
Open Circuit Voltage 15 V
Analog Input (AI)
Input Range 0 to 5 V/1 to 5 V, 0 to 20 mA/4 to 20 mA (sold separately)
Accuracy 0.5%
Temperature Drift 50 ppm/°C typical
Isolation Voltage 500 VDC
Power Supply for DI (24 VDC)
Output Voltage: 24 VDC
Current: 42 mA
Load (Maximum) 21 Dis
Operating Environment
Temperature Operation: -13 to 158°F (-25 to 70°C)
Storage: -40 to 185°F (-40 to 85°C)
Relative Humidity 5 to 95% non-condensing
Click here for complete specifications on the Accuenergy Acuvim II Series

What's included with the Accuenergy Acuvim II Series

  • Accuenergy Acuvim II Series Advanced Power and Energy Meters

Ask a question about Accuenergy Acuvim II Series Advanced Power and Energy Meters

Customer Reviews for the Accuenergy Acuvim II Series

More Accuenergy Products

Calibration Lab