Accuenergy ACUVIM-EL-M-5A-P2V3 Power Meter

Model: ACUVIM-EL-M-5A-P2V3

Accuenergy ACUVIM-EL-M-5A-P2V3 Power Meter

Model: ACUVIM-EL-M-5A-P2V3

Acuvim-EL Power Meter with MODBUS RS485 output and Time-of-Use (TOU), plus DIN-rail mount transducer form factor (no local display), 5A input for current transformers and low voltage DC power supply input.

Acuvim-EL Power Meter with MODBUS RS485 output and Time-of-Use (TOU), plus DIN-rail mount transducer form factor (no local display), 5A input for current transformers and low voltage DC power supply input.

Sale Price $501.40 USD
Regular Price $545.00 USD
Availability 3 to 4 Weeks
Quantity
Include an Enclosure for the Acuvim L series

Clear selected options

Include an Enclosure for the Acuvim L series

Clear selected options


Accuenergy Acuvim EL-M-5A-P2 Offers

The Acuvim-EL power meter is equipped with TOU for single and three phase circuits and is ideal for applications in which there are time-based tariff rates to properly align charges with usage in order to reduce costs. The Acuvim-EL features Modbus RS485 serial connection. It also includes 5A current input, 20 to 60V DC power supply, and DIN-rail mount transducer without display.

Features

  • Time-of-Use and tariff metering: 4 different tariffs, 12 seasons and 14 schedules
  • Optional modules include 4 digital inputs, 2 digital outputs, a second RS485 port with Modbus RTU protocol or Profibus port
  • True-RMS measurement parameters so that non-linear loads can be monitored
  • 4-quadrant energy measurement
  • Power quality analysis
  • Over/Under limit alarm
  • Max/Min statistics
  • Meter running time

Specifications

Metering
Parameters Acuvim-L Accuracy Acuvim-EL/KL Accuracy Resolution Range
Voltage 0.5% 0.5% 0.1V 20V~1000kV
Current 0.5% 0.5% 0.001A 0~50000A
Current Demand 0.5% 0.5% 0.001A 0~50000A
Power 1.0% 0.5% 1W -9999MW~9999MW
Reactive Power 2.0% 0.5% 1var -9999Mvar~9999Mvar
Apparent Power 1.0% 0.5% 0.001V 0~9999MVA
Power Demand 1.0% 0.5% 1W -9999MW~9999MW
Reactive Power Demand 2.0% 0.5% 1var -9999Mvar~9999Mvar
Apparent Power Demand 1.0% 1VA 1VA 0~9999MVA
Power Factor 1.0% 0.5% 0.001 -1.0~1.0
Frequency 0.2% 0.2% 0.01Hz 45.00~65.00Hz
Energy 0.5% 0.5% 0.1kWh 0~99999999.9kWh
Reactive Energy 2.0% 0.5% 0.1kvarh 0~99999999.9kvarh
Apparent Energy 1.0% 0.5% 0.1VAh 0~99999999.9kVAh
Harmonics 2.0% - 0.01% 0~100.0%
Running Time 0.1hrs 0~999999999.9hrs
Communication
RS-485 (Option)
Modbus-RTU Protocol
2-wire connection, Half-duplex, Isolated
1200 to 38400 baud rate
Input
Current Inputs (Each Channel)
Nominal Current 5 A ac
Metering Range 0~6 A ac
Withstand 20Arms continuous100Arms for 1 second, non-recurring
Burden 0.05VA (typical) @5Arms
Pickup Current 10Vac
Accuracy 0.5%
Voltage Inputs (Each Channel)
Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%)
Withstand 1500Vac continuous2500Vac, 50/60Hz for 1minute
Input Impedance 45Hz~65Hz
Pickup Voltage 10Vac
Accuracy 0.5%
Energy Accuracy (Acuvim-EL)
Active (according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Reactive (according to IEC 62053-23) Class 2
Harmonic Resolution
Metered Value 2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Control Power
Universal AC or DC
AC/DC Control Power
Operating Range 100~415Vac, 50/60Hz, 100~300Vdc
Burden 3W
Withstand 3250Vac, 50/60Hz for 1 minute
Low Voltage DC Control Power (Optional)
Operating Range 20~60Vdx
Burden 3W
Digital Output Option
Digital Output (DO) (Photo-MOS)
Voltage Range 0~250Vac/dc
Load Current 100mA (Max)
Output Frequency 25Hz, 50% Duty Ratio
Isolation Voltage 2500V
Digital Input Option
Digital Output (DI)
Input Voltage Range 20~250Vac/dc
Input Current (Max) 2mA
Start Voltage 15V
Stop Voltage 5V
Pulse Frequency (Max) 100Hz, 50% Duty Ratio
SOE Resolution 2ms
Operating Environment
Operation Temperature -25°C to 70°C
Storage Temperature -40°C to 85°C
Relative Humidity 5% to 95% non-condensing
Pollution Degree 2
Standard Compliance
Product
USA UL 61010-1
Canada cUL 61010-1
Europe IEC 61010-1
Emission
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted EN 55011
Harmonic IEC 61000-3-2
Voltage Fluctuation IEC 50081-2
Radio Interference IEC 50081-2
Immunity
ESD IEC 61000-4-2
Radiated, radio-frequency, electromagnetic field IEC 61000-4-3
Electrical fast transient/bust IEC 61000-4-4
Surge IEC 61000-4-5
Conducted disturbances IEC 61000-4-6
Power frequency magnetic field IEC 61000-4-8
Voltage dips and interruptions IEC 61000-4-11
Generic Immunity Standard for Industrial Environment EN 50082-2
Click here for complete specifications on the Accuenergy ACUVIM-EL-M-5A-P2V3

What's included with the Accuenergy ACUVIM-EL-M-5A-P2V3

  • Accuenergy ACUVIM-EL-M-5A-P2V3 Power Meter

Acuvim II Series Comparison

Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
Real Time Metering Phase Voltage U1, U2, U3
Real Time Metering Line Voltage U12, U23, U31
Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
Real Time Metering Power P1, P2, P3, Psum
Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Real Time Metering Apparent Power S1, S2, S3, Ssum
Real Time Metering Power Factor PF1, PF2, PF3, PF
Real Time Metering Load Nature L/C/R
Real Time Metering Frequency F Hz
Energy & Demand Energy Ep_imp, Ep_exp
Energy & Demand Reactive Energy Eq_imp, Eq_exp
Energy & Demand Apparent Energy Es
Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
Power Quality Voltage Unbalance U_unbl
Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Power Quality Voltage THD THD_V1, THD_V2, THD_V3
Power Quality Current THD THD_I1, THD_I2, THD_I3
Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
Statistics Max & Min of Voltage
Statistics Max & Min of Current
Hour Running Time Hour
Hour Load Running Time Hour
I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
I/O Alarm Output
Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Ask a question about Accuenergy ACUVIM-EL-M-5A-P2V3 Power Meter

Customer Reviews for the Accuenergy ACUVIM-EL-M-5A-P2V3

Accuenergy Acuvim EL-M-5A-P2 Offers

The Acuvim-EL power meter is equipped with TOU for single and three phase circuits and is ideal for applications in which there are time-based tariff rates to properly align charges with usage in order to reduce costs. The Acuvim-EL features Modbus RS485 serial connection. It also includes 5A current input, 20 to 60V DC power supply, and DIN-rail mount transducer without display.

Features

  • Time-of-Use and tariff metering: 4 different tariffs, 12 seasons and 14 schedules
  • Optional modules include 4 digital inputs, 2 digital outputs, a second RS485 port with Modbus RTU protocol or Profibus port
  • True-RMS measurement parameters so that non-linear loads can be monitored
  • 4-quadrant energy measurement
  • Power quality analysis
  • Over/Under limit alarm
  • Max/Min statistics
  • Meter running time

Specifications

Metering
Parameters Acuvim-L Accuracy Acuvim-EL/KL Accuracy Resolution Range
Voltage 0.5% 0.5% 0.1V 20V~1000kV
Current 0.5% 0.5% 0.001A 0~50000A
Current Demand 0.5% 0.5% 0.001A 0~50000A
Power 1.0% 0.5% 1W -9999MW~9999MW
Reactive Power 2.0% 0.5% 1var -9999Mvar~9999Mvar
Apparent Power 1.0% 0.5% 0.001V 0~9999MVA
Power Demand 1.0% 0.5% 1W -9999MW~9999MW
Reactive Power Demand 2.0% 0.5% 1var -9999Mvar~9999Mvar
Apparent Power Demand 1.0% 1VA 1VA 0~9999MVA
Power Factor 1.0% 0.5% 0.001 -1.0~1.0
Frequency 0.2% 0.2% 0.01Hz 45.00~65.00Hz
Energy 0.5% 0.5% 0.1kWh 0~99999999.9kWh
Reactive Energy 2.0% 0.5% 0.1kvarh 0~99999999.9kvarh
Apparent Energy 1.0% 0.5% 0.1VAh 0~99999999.9kVAh
Harmonics 2.0% - 0.01% 0~100.0%
Running Time 0.1hrs 0~999999999.9hrs
Communication
RS-485 (Option)
Modbus-RTU Protocol
2-wire connection, Half-duplex, Isolated
1200 to 38400 baud rate
Input
Current Inputs (Each Channel)
Nominal Current 5 A ac
Metering Range 0~6 A ac
Withstand 20Arms continuous100Arms for 1 second, non-recurring
Burden 0.05VA (typical) @5Arms
Pickup Current 10Vac
Accuracy 0.5%
Voltage Inputs (Each Channel)
Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%)
Withstand 1500Vac continuous2500Vac, 50/60Hz for 1minute
Input Impedance 45Hz~65Hz
Pickup Voltage 10Vac
Accuracy 0.5%
Energy Accuracy (Acuvim-EL)
Active (according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Reactive (according to IEC 62053-23) Class 2
Harmonic Resolution
Metered Value 2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Control Power
Universal AC or DC
AC/DC Control Power
Operating Range 100~415Vac, 50/60Hz, 100~300Vdc
Burden 3W
Withstand 3250Vac, 50/60Hz for 1 minute
Low Voltage DC Control Power (Optional)
Operating Range 20~60Vdx
Burden 3W
Digital Output Option
Digital Output (DO) (Photo-MOS)
Voltage Range 0~250Vac/dc
Load Current 100mA (Max)
Output Frequency 25Hz, 50% Duty Ratio
Isolation Voltage 2500V
Digital Input Option
Digital Output (DI)
Input Voltage Range 20~250Vac/dc
Input Current (Max) 2mA
Start Voltage 15V
Stop Voltage 5V
Pulse Frequency (Max) 100Hz, 50% Duty Ratio
SOE Resolution 2ms
Operating Environment
Operation Temperature -25°C to 70°C
Storage Temperature -40°C to 85°C
Relative Humidity 5% to 95% non-condensing
Pollution Degree 2
Standard Compliance
Product
USA UL 61010-1
Canada cUL 61010-1
Europe IEC 61010-1
Emission
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted EN 55011
Harmonic IEC 61000-3-2
Voltage Fluctuation IEC 50081-2
Radio Interference IEC 50081-2
Immunity
ESD IEC 61000-4-2
Radiated, radio-frequency, electromagnetic field IEC 61000-4-3
Electrical fast transient/bust IEC 61000-4-4
Surge IEC 61000-4-5
Conducted disturbances IEC 61000-4-6
Power frequency magnetic field IEC 61000-4-8
Voltage dips and interruptions IEC 61000-4-11
Generic Immunity Standard for Industrial Environment EN 50082-2
Click here for complete specifications on the Accuenergy ACUVIM-EL-M-5A-P2V3

What's included with the Accuenergy ACUVIM-EL-M-5A-P2V3

  • Accuenergy ACUVIM-EL-M-5A-P2V3 Power Meter

Acuvim II Series Comparison

Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
Real Time Metering Phase Voltage U1, U2, U3
Real Time Metering Line Voltage U12, U23, U31
Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
Real Time Metering Power P1, P2, P3, Psum
Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Real Time Metering Apparent Power S1, S2, S3, Ssum
Real Time Metering Power Factor PF1, PF2, PF3, PF
Real Time Metering Load Nature L/C/R
Real Time Metering Frequency F Hz
Energy & Demand Energy Ep_imp, Ep_exp
Energy & Demand Reactive Energy Eq_imp, Eq_exp
Energy & Demand Apparent Energy Es
Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
Power Quality Voltage Unbalance U_unbl
Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Power Quality Voltage THD THD_V1, THD_V2, THD_V3
Power Quality Current THD THD_I1, THD_I2, THD_I3
Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
Statistics Max & Min of Voltage
Statistics Max & Min of Current
Hour Running Time Hour
Hour Load Running Time Hour
I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
I/O Alarm Output
Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Ask a question about Accuenergy ACUVIM-EL-M-5A-P2V3 Power Meter

Customer Reviews for the Accuenergy ACUVIM-EL-M-5A-P2V3

More Accuenergy Products

Calibration Lab