Source and measure most process parameters such as mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure using optional pressure modules (sold separately) with this process calibrator. It is intrinsically safe for use in explosion endangered areas. Additionally, it features auto-stepping and auto-ramping.
Source and measure most process parameters such as mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure using optional pressure modules (sold separately) with this process calibrator. It is intrinsically safe for use in explosion endangered areas. Additionally, it features auto-stepping and auto-ramping.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
Features
Applications
Measurement Accuracy | |
Voltage DC | 30.000 V: 0.02% + 2 counts (upper display) 10.000 V: 0.02% + 2 counts (lower display) 90.00 mV: 0.02% + 2 counts -10.00 to 75.00 mV: 0.025% + 1 count (via TC connector) |
Current DC | 24.000 mA: 0.02% + 2 counts |
Resistance | 0.0 to 400.0 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) 401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) 1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) |
Frequency | 2.0 to 1000.0 CPM: 0.05% + 1 count 1.0 to 1100.0 Hz: 0.05% + 1 count 1.00 to 10.00 kHz: 0.05% + 1 count Sensitivity: 1 V peak-to-peak-minimum |
Pressure | Accuracy from 0.025% of range using any of 8 intrinsic safe pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. |
Source Accuracy | |
Voltage DC | 100.00 mV: 0.02% + 2 counts 10.000 V: 0.02% + 2 counts -10.00 to 75.00 mV: 0.025% + 1 count (via TC connector) |
Current DC | 24.000 mA (source): 0.02% + 2 counts 24.000 mA (simulate): 0.02% + 2 counts |
Resistance | 15.0 to 400.0 Ω: 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) 401 to 1500 Ω: 0.5 Ω (excitation current 0.05 to 0.8 mA) 1500 to 3200 Ω: 1 Ω (excitation current 0.05 to 0.4 mA) |
Frequency | 2.0 to 1000.0 CPM: 0.05% 1.0 to 1100.0 Hz: 0.05% 1.00 to 10.00 kHz: 0.25% Waveform: 5 V p-p squarewave, -0.1 V offset |
RTDs and Thermocouples | |
Measure Accuracy | NI-120: 32.36°F (0.2°C) PT-100 (385): 32.6°F (0.33°C) PT-100 (393): 32.54°F (0.3°C) PT-100 (JIS): 32.54°F (0.3°C) PT-200 (385): 32.36°F (0.2°C) PT-500 (385): 32.54°F (0.3°C) PT-1000 (385): 32.36°F (0.2°C) Resolution: 0.1°C J: 33.26°F (0.7°C) K: 33.44°F (0.8°C) T: 33.44°F (0.8°C) E: 33.26°F (0.7°C) R: 35.24°F (1.8°C) S: 34.7°F (1.5°C) B: 34.52°F (1.4°C) L: 33.26°F (0.7°C) U: 33.35°F (0.75°C) N: 33.62°F (0.9°C) Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F XK: 33.08°F (0.6°C) BP: 34.16°F (1.2°C) |
Source Accuracy | NI-120: 32.36°F (0.2°C) PT-100 (385): 32.6°F (0.33°C) PT-100 (393): 32.54°F (0.3°C) PT-100 (JIS): 32.54°F (0.3°C) PT-200 (385): 32.36°F (0.2°C) PT-500 (385): 32.54°F (0.3°C) PT-1000 (385): 32.36°F (0.2°C) Resolution: 0.1°C Accuracy stated for 4-wire measurement. J: 33.26°F (0.7°C) K: 33.44°F (0.8°C) T: 33.44°F (0.8°C) E: 33.26°F (0.7°C) R: 34.52°F (1.4°C) S: 34.7°F (1.5°C) B: 34.52°F (1.4°C) L: 33.26°F (0.7°C) U: 33.35°F (0.75°C) N: 33.62°F (0.9°C) Resolution: J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C XK: 33.08°F (0.6°C) BP: 34.16°F (1.2°C) |
Functions Specifications | |
Ramp Functions | Source functions: Voltage, current, resistance, frequency, temperature Ramps: Slow ramp, Fast ramp, 25% step-ramp |
Loop Power Function | Voltage: 12 V Accuracy: 10% Maximum current: 22 mA, short circuit protected |
Step Functions | Source functions: Voltage, current, resistance, frequency, temperature Steps: 25% of range, 100% of range |
Mechanical and General Specifications | |
Batteries | 4 x AA alkaline batteries |
Battery Replacement | Separate battery compartment, accessible without breaking calibration seal |
Side Port Connections | Pressure module connector |
Dimensions | 5.188 x 9.291 x 2.402" (130 x 236 x 61 mm) |
Weight | 1.874 lbs (0.85 kg) |
Safety Specifications | |
Agency Approvals | I.S. Class I, Division 1 Groups B-D |
Click on a category to view a selection of compatible accessories with the Fluke 725EX Intrinsically Safe Multifunction Process Calibrator.
Measurement Accuracy | |
Voltage DC | 30.000 V: 0.02% + 2 counts (upper display) 10.000 V: 0.02% + 2 counts (lower display) 90.00 mV: 0.02% + 2 counts -10.00 to 75.00 mV: 0.025% + 1 count (via TC connector) |
Current DC | 24.000 mA: 0.02% + 2 counts |
Resistance | 0.0 to 400.0 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) 401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) 1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) |
Frequency | 2.0 to 1000.0 CPM: 0.05% + 1 count 1.0 to 1100.0 Hz: 0.05% + 1 count 1.00 to 10.00 kHz: 0.05% + 1 count Sensitivity: 1 V peak-to-peak-minimum |
Pressure | Accuracy from 0.025% of range using any of 8 intrinsic safe pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. |
Source Accuracy | |
Voltage DC | 100.00 mV: 0.02% + 2 counts 10.000 V: 0.02% + 2 counts -10.00 to 75.00 mV: 0.025% + 1 count (via TC connector) |
Current DC | 24.000 mA (source): 0.02% + 2 counts 24.000 mA (simulate): 0.02% + 2 counts |
Resistance | 15.0 to 400.0 Ω: 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) 401 to 1500 Ω: 0.5 Ω (excitation current 0.05 to 0.8 mA) 1500 to 3200 Ω: 1 Ω (excitation current 0.05 to 0.4 mA) |
Frequency | 2.0 to 1000.0 CPM: 0.05% 1.0 to 1100.0 Hz: 0.05% 1.00 to 10.00 kHz: 0.25% Waveform: 5 V p-p squarewave, -0.1 V offset |
RTDs and Thermocouples | |
Measure Accuracy | NI-120: 32.36°F (0.2°C) PT-100 (385): 32.6°F (0.33°C) PT-100 (393): 32.54°F (0.3°C) PT-100 (JIS): 32.54°F (0.3°C) PT-200 (385): 32.36°F (0.2°C) PT-500 (385): 32.54°F (0.3°C) PT-1000 (385): 32.36°F (0.2°C) Resolution: 0.1°C J: 33.26°F (0.7°C) K: 33.44°F (0.8°C) T: 33.44°F (0.8°C) E: 33.26°F (0.7°C) R: 35.24°F (1.8°C) S: 34.7°F (1.5°C) B: 34.52°F (1.4°C) L: 33.26°F (0.7°C) U: 33.35°F (0.75°C) N: 33.62°F (0.9°C) Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F XK: 33.08°F (0.6°C) BP: 34.16°F (1.2°C) |
Source Accuracy | NI-120: 32.36°F (0.2°C) PT-100 (385): 32.6°F (0.33°C) PT-100 (393): 32.54°F (0.3°C) PT-100 (JIS): 32.54°F (0.3°C) PT-200 (385): 32.36°F (0.2°C) PT-500 (385): 32.54°F (0.3°C) PT-1000 (385): 32.36°F (0.2°C) Resolution: 0.1°C Accuracy stated for 4-wire measurement. J: 33.26°F (0.7°C) K: 33.44°F (0.8°C) T: 33.44°F (0.8°C) E: 33.26°F (0.7°C) R: 34.52°F (1.4°C) S: 34.7°F (1.5°C) B: 34.52°F (1.4°C) L: 33.26°F (0.7°C) U: 33.35°F (0.75°C) N: 33.62°F (0.9°C) Resolution: J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C XK: 33.08°F (0.6°C) BP: 34.16°F (1.2°C) |
Functions Specifications | |
Ramp Functions | Source functions: Voltage, current, resistance, frequency, temperature Ramps: Slow ramp, Fast ramp, 25% step-ramp |
Loop Power Function | Voltage: 12 V Accuracy: 10% Maximum current: 22 mA, short circuit protected |
Step Functions | Source functions: Voltage, current, resistance, frequency, temperature Steps: 25% of range, 100% of range |
Mechanical and General Specifications | |
Batteries | 4 x AA alkaline batteries |
Battery Replacement | Separate battery compartment, accessible without breaking calibration seal |
Side Port Connections | Pressure module connector |
Dimensions | 5.188 x 9.291 x 2.402" (130 x 236 x 61 mm) |
Weight | 1.874 lbs (0.85 kg) |
Safety Specifications | |
Agency Approvals | I.S. Class I, Division 1 Groups B-D |
Click on a category to view a selection of compatible accessories with the Fluke 725EX Intrinsically Safe Multifunction Process Calibrator.