Work with this multifunctional PV tester and performance analyzer kit that provides an all-in-one test solution to test PV system performance and safety, and expedite client reporting. In addition, this kit comes complete with an AC/DC current clamp, solar irradiance meter, test lead sets, test probe with a remote button, and a backpack.
Work with this multifunctional PV tester and performance analyzer kit that provides an all-in-one test solution to test PV system performance and safety, and expedite client reporting. In addition, this kit comes complete with an AC/DC current clamp, solar irradiance meter, test lead sets, test probe with a remote button, and a backpack.
All-in-one test solution that provides a complete PV testing solution that conforms to IEC 62446-1 standard.
Features
Keep the leads: Quick and accurate testing saves time and money
It's a hassle to change the configuration of test leads constantly while doing different tests. With the "keep the leads" system, less time is wasted on set-up, and less user errors occur while testing PV systems. Now you can get more testing done in the field in less time.
Automatic testing saves time
Switch this unit to auto test mode to perform an automatic sequence of tests in a variety of combinations:
On-location I-V curve results: Compare manufacturer I-V curve data to measured data instantly
While taking an I-V curve reading in the field, this tester will display the curve as it loads in the test data, against the module specifications as defined by the manufacturer. This makes it easy to immediately confirm measurements without the use of a laptop or tablet. Run the I-V curve test on new installations to confirm they are working according to the site specifications, or to test if existing modules or strings are working to their expected performance levels.
Visual inspection
To meet PV system IEC regulations for visual inspections, this tester features a convenient setting in which to record observations directly to the memory. Later, the information can be downloaded to the TruTest software (sold separately) and incorporated into the project report.
Recommended tools
Applications
Protective Conductor Resistance RLO | |
Display Range | 0 to 19.99 Ω 20 to 199.9 Ω 200 to 2000 Ω |
Measuring Range | 0.20 to 19.99 Ω 20 to 199.9 Ω 200 to 2000 Ω |
Resolution | 0.01/0.1/1 Ω |
Accuracy | ±(2% + 2 digits) ±(2% + 2 digits) ±(5% + 2 digits) |
Test | Current: ≥200 mA (≤2 Ω + Rcomp) Voltage: 4 to 10 V DC Lead zero (Rcomp): Up to 3 Ω |
Polarity Reversing | Yes |
PV Module/PV String, Open-Circuit Voltage (Voc) | |
Display Range | 0 to 99.9 V 100 to 1000 V |
Measuring Range | 5 to 99.9 V 100 to 1000 V |
Resolution | 0.1/1 V |
Accuracy | ±(0.5% + 2 digits) ±(0.5% + 2 digits) |
Polarity Test | Yes |
PV Module/PV String, Short-Circuit Current (Is/c) | |
Display Range | 0 to 20 A |
Measuring Range | 0.2 to 20 A |
Resolution | 0.1 A |
Accuracy | ±(1% + 2 digits) |
Insulation Resistance RINS | |
Display Range | 0 to 99.99 MΩ 100 to 199.9 MΩ 200 to 999 MΩ Testing current: Minimum: 1 mA (at 250 kΩ/500 kΩ/1 MΩ); Maximum: 1.5 mA (short circuit) |
Measuring Range | 0.20 to 99.99 MΩ 100 to 199.9 MΩ 200 to 999 MΩ |
Resolution | 0.01/0.1/1 Ω |
Accuracy | ±(5% + 5 digits) ±(10% + 5 digits) ±(20% + 5 digits) |
Test Voltage at No Load | Measuring range: 50/100/250 V up to 199.9 MΩ; 500/1000 V up to 999 MΩ Resolution: 1 V Accuracy: 0 to 20% |
Test Voltage at ≥1 mA | Measuring range: 250 V at 250 kΩ; 500 V at 500 kΩ; 1000 V at 1 MΩ Resolution: 1 V Accuracy: 0 to 10% |
Testing Current | Minimum: 1 mA (at 250 kΩ/500 kΩ/1 MΩ) Maximum 1.5 mA (short circuit) |
General Specifications | |
Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: -22 to 140°F (30 to 60°C) |
Altitude | Up to 6561.68'/2000 m (operating and storage) |
Battery | 6 AA IEC LR6 |
Safety | IEC 61010-1 Pollution°2 IEC 61010-2-034 CAT III 1000 V DC, CAT III 700 V AC |
Electromagnetic Compatibility (EMC) | IEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. |
Wireless Radio Module | Frequency range: 2.402 to 2.48 GHz Output power: 8 dBm |
Dimensions | 3.8 x 9.8 x 4.9" (10 x 25 x 12.5 cm) |
Weight | 3.09 lbs (1.4 kg) |
Click on a category to view a selection of compatible accessories with the Fluke SMFT-1000 Multifunction PV Tester and Performance Analyzer Kit with irradiance meter and current clamp, 1000 V, 20/400 A.
Protective Conductor Resistance RLO | |
Display Range | 0 to 19.99 Ω 20 to 199.9 Ω 200 to 2000 Ω |
Measuring Range | 0.20 to 19.99 Ω 20 to 199.9 Ω 200 to 2000 Ω |
Resolution | 0.01/0.1/1 Ω |
Accuracy | ±(2% + 2 digits) ±(2% + 2 digits) ±(5% + 2 digits) |
Test | Current: ≥200 mA (≤2 Ω + Rcomp) Voltage: 4 to 10 V DC Lead zero (Rcomp): Up to 3 Ω |
Polarity Reversing | Yes |
PV Module/PV String, Open-Circuit Voltage (Voc) | |
Display Range | 0 to 99.9 V 100 to 1000 V |
Measuring Range | 5 to 99.9 V 100 to 1000 V |
Resolution | 0.1/1 V |
Accuracy | ±(0.5% + 2 digits) ±(0.5% + 2 digits) |
Polarity Test | Yes |
PV Module/PV String, Short-Circuit Current (Is/c) | |
Display Range | 0 to 20 A |
Measuring Range | 0.2 to 20 A |
Resolution | 0.1 A |
Accuracy | ±(1% + 2 digits) |
Insulation Resistance RINS | |
Display Range | 0 to 99.99 MΩ 100 to 199.9 MΩ 200 to 999 MΩ Testing current: Minimum: 1 mA (at 250 kΩ/500 kΩ/1 MΩ); Maximum: 1.5 mA (short circuit) |
Measuring Range | 0.20 to 99.99 MΩ 100 to 199.9 MΩ 200 to 999 MΩ |
Resolution | 0.01/0.1/1 Ω |
Accuracy | ±(5% + 5 digits) ±(10% + 5 digits) ±(20% + 5 digits) |
Test Voltage at No Load | Measuring range: 50/100/250 V up to 199.9 MΩ; 500/1000 V up to 999 MΩ Resolution: 1 V Accuracy: 0 to 20% |
Test Voltage at ≥1 mA | Measuring range: 250 V at 250 kΩ; 500 V at 500 kΩ; 1000 V at 1 MΩ Resolution: 1 V Accuracy: 0 to 10% |
Testing Current | Minimum: 1 mA (at 250 kΩ/500 kΩ/1 MΩ) Maximum 1.5 mA (short circuit) |
General Specifications | |
Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: -22 to 140°F (30 to 60°C) |
Altitude | Up to 6561.68'/2000 m (operating and storage) |
Battery | 6 AA IEC LR6 |
Safety | IEC 61010-1 Pollution°2 IEC 61010-2-034 CAT III 1000 V DC, CAT III 700 V AC |
Electromagnetic Compatibility (EMC) | IEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. |
Wireless Radio Module | Frequency range: 2.402 to 2.48 GHz Output power: 8 dBm |
Dimensions | 3.8 x 9.8 x 4.9" (10 x 25 x 12.5 cm) |
Weight | 3.09 lbs (1.4 kg) |
Click on a category to view a selection of compatible accessories with the Fluke SMFT-1000 Multifunction PV Tester and Performance Analyzer Kit with irradiance meter and current clamp, 1000 V, 20/400 A.