Reliable and accurate, this 384 x 288 resolution thermal camera features voice annotation, IR-PhotoNotes, and asset tagging. Store inspection notes and location information directly with the captured images with this camera for a proactive maintenance (PM) program.
Reliable and accurate, this 384 x 288 resolution thermal camera features voice annotation, IR-PhotoNotes, and asset tagging. Store inspection notes and location information directly with the captured images with this camera for a proactive maintenance (PM) program.
Be proactive instead of reactive and ditch the clipboard. Take your plan for a proactive maintenance (PM) program and transform it into reality. To get started, you need features that make it easy to set up your image organization and inspection routines, and along with this thermal camera, you’re well on your way to implementing a successful PM program.
Features
Ditch the clipboard
With so many inspections in your day, it can be hard to remember what you saw and where you inspected. Maybe you carry around a clipboard to jot down notes. The thermal camera come with built-in personal assistants, which means you can finally ditch the clipboard and have all the information you need embedded in the images you save, including:
Applications
Infrared cameras, also called thermal imagers, are useful for troubleshooting motor problems as well as for monitoring motor condition for preventative maintenance in power generation, manufacturing and commercial plants. Thermal images of motors reveal their operating condition as indicated by surface temperature. Such condition monitoring is important as a way to avert many unexpected motor malfunctions in systems that are critical to manufacturing. The onset of motor failures can often be detected by a variety of techniques, including vibration, ultrasound and thermal imaging.
In this article, we cover why use thermal imaging and what to scan, as well as some notes on what to look for, including shaft misalignment.
Read the ArticleKey Specifications | |
Infrared Resolution | 384 x 288 (110,592 pixels) |
IFOV | 1.91 mRad |
Field of View | 42 x 30° |
Minimum Focus Distance | 1.64' (0.5 m) |
Focus System | Manual focus and 1 meter focus marker |
Asset Tagging | Scan a QR code to automatically organize and file thermal images with Fluke Connect™ |
IR-Fusion Technology | AutoBlend continuous 0 to 100%. Adds the context of the visible details to your infrared image |
Picture-In-Picture (PIP) | Yes |
Display | 3.5" (8.9 cm landscape) touchscreen 640 x 480 LCD |
Thermal Sensitivity | 40 mk |
Level and Span | Smooth auto and manual scaling |
Fast Auto-Rescale in Manual Mode | Yes |
Minimum Span | Manual mode: 4.5°F (3°C) Auto mode: 9°F (5°C) |
Built-in Digital Camera (Visible Light) | Up to 5mp |
Frame Rate | 27 Hz |
Data Storage and Image Capture | |
Memory | Internal: ~500 images External: ≥4 GB SD card (>1000 images) |
Image File Formats | Non-radiometric BMP or JPEG or fully-radiometric is2 |
Software | Fluke Connect software - full analysis and reporting software with access to the Fluke Connect |
Voice Annotation | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device |
IR-PhotoNotes | Yes. Up to 1 extra user-selectable visible light image capture to be included in IS2 file |
Text Annotations | After IS2 capture, user can type in a note using on-screen keyboard |
Auto Capture (Temperature and Interval) | Yes. User-selectable time interval for capturing IS2 or Jpeg files |
Temperature Measurement | |
Temperature Range |
-4 to 1022°F (-20 to 550°C) |
Accuracy | ±2°C or 2% (whichever is greater) at 25°C ambient temperature |
On-Screen Emissivity Correction | Yes, "top ten" material list plus numerical adjustment between 0.01 and 1.00 |
General Specifications | |
Standard Palettes | 6 |
Color Alarms | Yes. User-selectable hot and cold point and internal/external range color alarms. Modifies palettization of IR image by limiting which pixels are drawn using palette colors based on the pixel temperature |
Infrared Spectral Band | ~8 to 14 μm |
Temperature | Operating: 14 to 122°F (-10 to 50°C) Storage: -4 to 122°F (-20 to 50°C) without batteries |
Relative Humidity | 10 to 95% non-condensing |
Spot Temperature | Center spot (unmovable) |
User-Definable Spot Markers | Yes, 3 user-adjustable spot markers for a single pixel each. Position is adjustable. Temperature value for marker shown on screen. User can choose to switch display on/off for each marker |
User Defined Measurement Boxes | Yes, 3 user-adjustable rectangles. Size and position are adjustable. Rectangle statistics shown on screen: Min, Max, Average temperature. User can choose to switch display on/off for each marker |
Safety Standards | IEC 61010-1: Pollution Degree 2 |
Electromagnetic Compatibility | IEC 61326-1: Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A |
Vibration | 10 to 150 Hz, 0.15 mm, IEC 60068-2-6 |
Shock | 30 g, 11 ms, IEC 60068-2-27 |
Drop | Engineered to withstand 6.56' (2 m) drop |
Battery | Type: Lithium-ion rechargeable battery Life: ≥3.5 hours continuous without WiFi (actual life depends on settings and usage) Charging time: ≤2.5 hours to full charge |
Enclosure Rating | IP54 |
Supported Languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
RoHS Compliant | Yes |
Dimensions | ~10.5 x 4 x 5.7" (26.7 x 10.1 x 14.5 cm) |
Weight | ≤5 lbs (2.27 kg), including batteries |
Model | Fluke TiS75+ | Fluke TiS60+ | Fluke TiS55+ | Fluke TiS20+ Fluke TiS20+ MAX |
---|---|---|---|---|
Infrared resolution | 384 x 288 (110,592 pixels) | 320 x 240 (76,800 pixels) | 256 x 192 (49,152 pixels) | 120 x 90 (10,800 pixels) |
IFOV (spatial resolution) | 1.91 mRad | 1.86 mRad | 1.91 mRad | 7.6 mRad |
Field of view | 42°H x 30°V | 34.1 °H x 25.6°V | 28°H x 20°V | 50°H x 38°V |
Distance to spot | 130:1 | |||
Thermal sensitivity* | Target temp at or over 0°C (40 mk) | ≤ 0.045 at 30°C target temp (45 mK) | Target temp at or over 0°C (40 mk) | Target temp at or over 0°C (60 mK) |
Temperature range | -4 to 1022°F (-20 to 550°C) (not calibrated below -10°C) | -4 to 752°F (-20 to 400°C) | -4 to 1022°F (-20 to 550°C) (not calibrated below -10°C) | TiS20+-4 to +302°F (-20 to 150°C) TiS20+ MAX-4 to +752°F (-20 to 400°C) |
Focus system | Manual focus plus focus free operation for distances >0.5m via focus marker |
Fixed Focus | Manual focus, plus focus free operation for distances >0.5m via focus marker |
Fixed Focus |
Level and span | Smooth auto and manual scaling | |||
Optional lenses | ||||
Wireless connectivity** | Fluke Connect™ app compatible. Wireless connectivity to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN | |||
IR-Fusion® | AutoBlend continuous 0 to 100 % | Yes, 4 levels 0%, 25%, 50%, 75%, 100% | AutoBlend continuous 0 to 100 % | Continuous Touchscreen IR-Fusion 0 to 100% |
Display | 3.5” (8.9 cm landscape) touchscreen 640 x 480 LCD | 3.5” (8.9 cm landscape) 320 x 240 LCD | 3.5” (8.9 cm landscape) touchscreen 640 x 480 LCD | 3.5” (8.9 cm landscape) touchscreen 320 x 240 LCD |
Design | Pistol-grip design for one-handed use | |||
Frame rate | 9 or 27 Hz models | < 9 or 30 Hz | 9 or 27 Hz models | 9 Hz |
Software | Full analysis and reporting software with access to Fluke Connect Desktop | |||
Voice annotation | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device (sold separately) | 60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset required (sold separately) | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device (sold separately) | |
Text annotation | After IS2 capture, user can type in a note using on-screen keyboard. |
After IS2 capture, user can type in a note using on-screen keyboard. |
Yes. Including standard shortcuts as well as user programmable options | |
Video recording | Standard and radiometric video. Up to 5 minute recording length. avi and is 3 |
|||
Battery life | ≥ 3.5 hours continuous without WiFi (Actual life depends on settings and usage) |
4 hours continuous use per battery pack (without WiFi) | ≥ 3.5 hours continuous without WiFi (Actual life depends on settings and usage) |
≥ 5 hours continuous (without WiFi) |
Remote control operation | ||||
Alarms | High temperature, low temperature, and dew point calculation | High temperature, low temperature, isotherms (within range) | High temperature, low temperature | |
Warranty | 2 year warranty | 2 year warranty | 2 year warranty | 2 year warranty |
Asset tagging | Automatically organize and file thermal images by scanning QR codes | Automatically organize and file thermal images by scanning QR codes | Automatically organize and file thermal images by scanning QR codes |
*Best possible **Fluke Connect™ not available in all countries
Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.
Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.
Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Click on a category to view a selection of compatible accessories with the Fluke TiS75+ Thermal Imager, 384 x 288.
Key Specifications | |
Infrared Resolution | 384 x 288 (110,592 pixels) |
IFOV | 1.91 mRad |
Field of View | 42 x 30° |
Minimum Focus Distance | 1.64' (0.5 m) |
Focus System | Manual focus and 1 meter focus marker |
Asset Tagging | Scan a QR code to automatically organize and file thermal images with Fluke Connect™ |
IR-Fusion Technology | AutoBlend continuous 0 to 100%. Adds the context of the visible details to your infrared image |
Picture-In-Picture (PIP) | Yes |
Display | 3.5" (8.9 cm landscape) touchscreen 640 x 480 LCD |
Thermal Sensitivity | 40 mk |
Level and Span | Smooth auto and manual scaling |
Fast Auto-Rescale in Manual Mode | Yes |
Minimum Span | Manual mode: 4.5°F (3°C) Auto mode: 9°F (5°C) |
Built-in Digital Camera (Visible Light) | Up to 5mp |
Frame Rate | 27 Hz |
Data Storage and Image Capture | |
Memory | Internal: ~500 images External: ≥4 GB SD card (>1000 images) |
Image File Formats | Non-radiometric BMP or JPEG or fully-radiometric is2 |
Software | Fluke Connect software - full analysis and reporting software with access to the Fluke Connect |
Voice Annotation | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device |
IR-PhotoNotes | Yes. Up to 1 extra user-selectable visible light image capture to be included in IS2 file |
Text Annotations | After IS2 capture, user can type in a note using on-screen keyboard |
Auto Capture (Temperature and Interval) | Yes. User-selectable time interval for capturing IS2 or Jpeg files |
Temperature Measurement | |
Temperature Range |
-4 to 1022°F (-20 to 550°C) |
Accuracy | ±2°C or 2% (whichever is greater) at 25°C ambient temperature |
On-Screen Emissivity Correction | Yes, "top ten" material list plus numerical adjustment between 0.01 and 1.00 |
General Specifications | |
Standard Palettes | 6 |
Color Alarms | Yes. User-selectable hot and cold point and internal/external range color alarms. Modifies palettization of IR image by limiting which pixels are drawn using palette colors based on the pixel temperature |
Infrared Spectral Band | ~8 to 14 μm |
Temperature | Operating: 14 to 122°F (-10 to 50°C) Storage: -4 to 122°F (-20 to 50°C) without batteries |
Relative Humidity | 10 to 95% non-condensing |
Spot Temperature | Center spot (unmovable) |
User-Definable Spot Markers | Yes, 3 user-adjustable spot markers for a single pixel each. Position is adjustable. Temperature value for marker shown on screen. User can choose to switch display on/off for each marker |
User Defined Measurement Boxes | Yes, 3 user-adjustable rectangles. Size and position are adjustable. Rectangle statistics shown on screen: Min, Max, Average temperature. User can choose to switch display on/off for each marker |
Safety Standards | IEC 61010-1: Pollution Degree 2 |
Electromagnetic Compatibility | IEC 61326-1: Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A |
Vibration | 10 to 150 Hz, 0.15 mm, IEC 60068-2-6 |
Shock | 30 g, 11 ms, IEC 60068-2-27 |
Drop | Engineered to withstand 6.56' (2 m) drop |
Battery | Type: Lithium-ion rechargeable battery Life: ≥3.5 hours continuous without WiFi (actual life depends on settings and usage) Charging time: ≤2.5 hours to full charge |
Enclosure Rating | IP54 |
Supported Languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
RoHS Compliant | Yes |
Dimensions | ~10.5 x 4 x 5.7" (26.7 x 10.1 x 14.5 cm) |
Weight | ≤5 lbs (2.27 kg), including batteries |
Model | Fluke TiS75+ | Fluke TiS60+ | Fluke TiS55+ | Fluke TiS20+ Fluke TiS20+ MAX |
---|---|---|---|---|
Infrared resolution | 384 x 288 (110,592 pixels) | 320 x 240 (76,800 pixels) | 256 x 192 (49,152 pixels) | 120 x 90 (10,800 pixels) |
IFOV (spatial resolution) | 1.91 mRad | 1.86 mRad | 1.91 mRad | 7.6 mRad |
Field of view | 42°H x 30°V | 34.1 °H x 25.6°V | 28°H x 20°V | 50°H x 38°V |
Distance to spot | 130:1 | |||
Thermal sensitivity* | Target temp at or over 0°C (40 mk) | ≤ 0.045 at 30°C target temp (45 mK) | Target temp at or over 0°C (40 mk) | Target temp at or over 0°C (60 mK) |
Temperature range | -4 to 1022°F (-20 to 550°C) (not calibrated below -10°C) | -4 to 752°F (-20 to 400°C) | -4 to 1022°F (-20 to 550°C) (not calibrated below -10°C) | TiS20+-4 to +302°F (-20 to 150°C) TiS20+ MAX-4 to +752°F (-20 to 400°C) |
Focus system | Manual focus plus focus free operation for distances >0.5m via focus marker |
Fixed Focus | Manual focus, plus focus free operation for distances >0.5m via focus marker |
Fixed Focus |
Level and span | Smooth auto and manual scaling | |||
Optional lenses | ||||
Wireless connectivity** | Fluke Connect™ app compatible. Wireless connectivity to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN | |||
IR-Fusion® | AutoBlend continuous 0 to 100 % | Yes, 4 levels 0%, 25%, 50%, 75%, 100% | AutoBlend continuous 0 to 100 % | Continuous Touchscreen IR-Fusion 0 to 100% |
Display | 3.5” (8.9 cm landscape) touchscreen 640 x 480 LCD | 3.5” (8.9 cm landscape) 320 x 240 LCD | 3.5” (8.9 cm landscape) touchscreen 640 x 480 LCD | 3.5” (8.9 cm landscape) touchscreen 320 x 240 LCD |
Design | Pistol-grip design for one-handed use | |||
Frame rate | 9 or 27 Hz models | < 9 or 30 Hz | 9 or 27 Hz models | 9 Hz |
Software | Full analysis and reporting software with access to Fluke Connect Desktop | |||
Voice annotation | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device (sold separately) | 60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset required (sold separately) | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device (sold separately) | |
Text annotation | After IS2 capture, user can type in a note using on-screen keyboard. |
After IS2 capture, user can type in a note using on-screen keyboard. |
Yes. Including standard shortcuts as well as user programmable options | |
Video recording | Standard and radiometric video. Up to 5 minute recording length. avi and is 3 |
|||
Battery life | ≥ 3.5 hours continuous without WiFi (Actual life depends on settings and usage) |
4 hours continuous use per battery pack (without WiFi) | ≥ 3.5 hours continuous without WiFi (Actual life depends on settings and usage) |
≥ 5 hours continuous (without WiFi) |
Remote control operation | ||||
Alarms | High temperature, low temperature, and dew point calculation | High temperature, low temperature, isotherms (within range) | High temperature, low temperature | |
Warranty | 2 year warranty | 2 year warranty | 2 year warranty | 2 year warranty |
Asset tagging | Automatically organize and file thermal images by scanning QR codes | Automatically organize and file thermal images by scanning QR codes | Automatically organize and file thermal images by scanning QR codes |
*Best possible **Fluke Connect™ not available in all countries
Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.
Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.
Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Click on a category to view a selection of compatible accessories with the Fluke TiS75+ Thermal Imager, 384 x 288.