Fluke 28-II TRMS Industrial Multimeter with IP67 Rating

Model: 28-II | UPC: 095969461719

Fluke 28-II TRMS Industrial Multimeter with IP67 Rating

Model: 28-II | UPC: 095969461719

Highly durable True RMS AC/DC digital multimeter that offers IP67 waterproof and dustproof protection and can withstand a 10ft/3m drop test and comes with a limited lifetime warranty. Includes extended bandwidth, and a function for accurate voltage/frequency readings on VFDs and other electrically noisy devices. Ideal for harsh industrial applications.

Highly durable True RMS AC/DC digital multimeter that offers IP67 waterproof and dustproof protection and can withstand a 10ft/3m drop test and comes with a limited lifetime warranty. Includes extended bandwidth, and a function for accurate voltage/frequency readings on VFDs and other electrically noisy devices. Ideal for harsh industrial applications.

Sale Price $580.99 USD
Regular Price $699.99 USD
Availability 3 in Stock
Quantity

Traceable In-House Calibration Certificate for your 28-II TRMS Industrial Multimeter with IP67 Rating

Traceable In-House Calibration Certificate for your 28-II TRMS Industrial Multimeter with IP67 Rating

Fluke 28-II Offers

Features

  • 10,000µF capacitance range
  • Frequency measurement to 200kHz
  • True-RMS AC voltage and current measurements on non-linear signals
  • Extended AC voltage bandwidth; 15Hz to 20kHz
  • Resistance, continuity and diode test
  • Auto and manual ranging for maximum flexibility
  • Min/Max and average recording to capture variations automatically
  • Peak min/max
  • Relative mode to remove test lead resistance from low ohms measurements
  • Unique function for accurate voltage and frequency measurements on adjustable speed motor rives and other electrically noisy equipment
  • Built-in thermometer conveniently allows you to take temperature measurements
  • Hi resolution 20,000-count display mode
  • Large display digits and two-level backlight
  • Backlit keypad buttons allow for easy visibility in lowlit areas
  • Withstands 8000V spikes caused by load switching and faults
  • Reversible holster for added protection when not in use
  • Designed to withstand 3m drop
  • IP67 waterproof and dustproof protection, completely sealed for use in harsh environments
  • Cat. IV 600V, Cat. III 1000V safety ratings

Fluke 28-II Specifications

Voltage Range 0.1mV to 1000V AC/DC
Voltage Accuracy AC: ±0.7% rdg. +4 dgt.
DC: ±0.05% rdg. +1 dgt.
Current Range 0.1µA to 10A AC/DC
Current Accuracy AC: ±1.0% rdg. +2 dgt.
DC: ±0.2% rdg. +4 dgt.
Resistance Range 0.1Ω to 50MΩ
Capacitance Range 1nF to 9999ΩF
Frequency Range 0.5Hz to 199.99kHz
Temperature Range -200 to 1090°C
Click here for complete specifications on the Fluke 28-II

What's included with the Fluke 28-II

  • 28-II Industrial Multimeter
  • Holster
  • Test leads
  • Alligator clips
  • 80BK-A Temperature probe
  • Manual
  • CD-ROM
  • 3 x AA batteries (installed)

Multimeter measurements on adjustable speed drives

In the past, motor repair meant dealing with traditional three-phase motor failures that were largely the result of water, dust, grease, failed bearings, misaligned motor shafts, or just plain old age. But motor repair has changed in a big way with the introduction of electronically controlled motors, more commonly referred to as adjustable speed drives (ASDs). These drives present a unique set of measurement problems that can vex the most seasoned pro. Thanks to new technology, now for the first time you can take accurate electrical measurements with a DMM during the installation and maintenance of a drive and diagnose bad components and other conditions that may lead to premature failure.

Troubleshooting philosophy

Technicians use many different methods to troubleshoot an electrical circuit, and a good troubleshooter will always find the problem - eventually. The trick is tracking it down quickly and keeping downtime to a minimum. The most efficient troubleshooting procedure begins at the motor and then works systematically back to the electrical source, looking for the most obvious problems first. A lot of time and money can be wasted replacing perfectly good parts when the problem is simply a loose connection. As you go, take care to take accurate measurements. Nobody takes inaccurate measurements on purpose, but it's easy to do, especially when working in a high-energy, noisy environment like an ASD. Likewise, choosing the right test tools for troubleshooting the drive, the motor, and the connections are of utmost importance. This is especially true when taking voltage, frequency, and current measurements on the output side of the motor drive. But until now, there hasn't been a digital multimeter on the market able to accurately measure ASDs. Incorporates a selectable low pass filter* that allows for accurate drive output measurements that agree with the motor drive controller display indicator. Now, technicians won't have to guess whether the drive is operating correctly and delivering the correct voltage, current, or frequency for a given control setting.

Drive measurements

Input side measurements

Any good quality True RMS multimeter can verify proper input power to an ASD. The input voltage readings should be within 1% of one another when measured from phase to phase with no load. A significant unbalance may lead to erratic drive operation and should be corrected when discovered.

Output side measurements

On the flip side, a regular True RMS multimeter can't reliably read the output side of a pulse width modulated (PWM) motor drive, because the ASD applies pulse width modulated nonsinusoidal voltage to the motor terminals. A True RMS DMM reads the heating effect of the non-sinusoidal voltage applied to the motor, while the motor controller's output voltage reading only displays the RMS value of the fundamental component (typically from 30 Hz to 60 Hz). The causes of this discrepancy are bandwidth and shielding. Many of today's True RMS digital multimeters have bandwidths out to 20 kHz or more, causing them to respond not only to the fundamental component, which is what the motor responds to but to all of the high-frequency components generated by the PWM drive. And if the DMM isn't shielded for high-frequency noise, the drive controller's high noise levels make the measurement discrepancies even more extreme. With the bandwidth and shielding issues combined, many True RMS meters display readings as much as 20 to 30% higher than what the drive controller is indicating. The incorporated selectable low pass filter allows troubleshooters to take accurate voltage, current, and frequency measurements on the output side of the drive at either the drive itself or the motor terminals. With the filter selected, the readings for both voltage and frequency (motor speed) should agree with the associated drive control display indications, if available. The low pass filter also allows for accurate current measurements when used with Hall-effect type clamps. All of these measurements are especially helpful when taking measurements at the motor location when the drive's displays are not in view.

Taking safe measurements

Before taking any electrical measurements, be sure you understand how to take them safely. No test instrument is completely safe if used improperly, and many test instruments are not appropriate for testing adjustable speed drives. Also, make sure to use the appropriate personal protective equipment (PPE) for your specific working environment and measurements. If at all possible, never work alone.

Safety ratings for electrical test equipment

ANSI and the International Electrotechnical Commission (IEC) are the primary independent organizations that define safety standards for test equipment manufacturers. The IEC 61010 second edition standard for test equipment safety states two basic parameters: a voltage rating and a measurement category rating. The voltage rating is the maximum continuous working voltage the instrument is capable of measuring. The category ratings depict the measurement environment expected for a given category. Most three-phase ASD installations would be considered a CAT III measurement environment, with power supplied from either 480V or 600V distribution systems. When using a DMM for measurements on these high-energy systems, make sure it's rated at a minimum for CAT III 600V and preferably for CAT IV 600V/CAT III 1000V. The category rating and voltage limit are typically found on the front panel, at the input terminals. Dual-rated CAT IV 600V and CAT III 1000V. Refer to the ABC's of DMM Safety* from Fluke for additional information on category ratings and taking safe measurements.

How to take measurements

Now let's put the multimeter to the test. The measurements in the following procedure are designed to be made on a 480 volt 3 phase drive control at the control panel terminal strips. These procedures would also be valid for lower voltage 3 phase drives powered by either single or 3 phase supply voltages. For these tests, the motor is running at 50 Hz.

Input voltage

To measure the ac voltage supply to the input side of the drive at the drive:

  • Select the ac voltage function.
  • Connect the black probe to one of the three phase input terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase input terminals and record the reading.
  • Leaving the black probe on the reference phase now move the red probe to the third phase input and record this reading.
  • Make sure there's no more than a 1% difference between these two readings.

Input current

Measuring the input current generally requires a current clamp accessory. In most cases, either the input current exceeds the maximum current measurable by the current function, or it isn't practical to "break the circuit" to take an in-line series current measurement. Regardless of clamp type, insure that all readings are within 10% of each other for proper balance.

Transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A AC function.
  • Place the clamp around each of the input supply phase cables in succession, recording each of the readings as they are taken. Since these clamps output one milliamp per amp, the milliamp readings shown on the display are the actual phase current readings in amps.

Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the AC voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter is enabled, the meter will be in the 600 mV manual range mode.
  • Place the clamp around each of the input supply phase cables in succession, recording each of the readings as they are taken. Since these clamps output one millivolt per amp, the millivolt readings shown on the display are the actual phase current readings in amps.

Figure 1. Output voltage reading without using the low pass filter.


Figure 2. Output voltage reading with low pass filter enabled.

Output voltage

To measure the AC output voltage at either the drive or the motor terminals:

  • Plug the black test lead into the common jack and the red test lead into the V/W jack.
  • Select the AC voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the yellow button to enable the low pass filter. Now record the reading.
  • Leaving the black probe on the reference phase, now move the red probe to the third phase output voltage or motor terminal and record this reading.
  • Make sure that there's no more than a 1% difference between these two readings (see Figure 2). The readings should also agree with the controller display, panel if available.
  • If the low pass filter isn't enabled, the output voltage readings may be 10 to 30% higher, as on a regular DMM (see Figure 1).

Figure 3. Output frequency (motor speed) without the low pass filter.


Figure 4. Output frequency (motor speed) using the low pass filter.

Motor speed (Output frequency using voltage as a reference)

To determine motor speed, simply take a frequency measurement while using the low pass filter. The measurement can be made between any two of the phase voltage or motor terminals.

  • Plug the black test lead into the common jack and the red test lead into the V/W jack.
  • Select the ac voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the yellow button to enable the low pass filter.
  • Press the Hz button. The displayed reading in hertz will be the motor speed (see Figure 3). This measurement couldn't be made successfully without the low pass filter (see Figure 4).

Output current

TAs with input current, measuring the output current generally requires a current clamp accessory. Once again, regardless of clamp type, insure that all readings are within 10% of each other for proper balance.

Transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A ac function.
  • Place the clamp around each of the output phase cables in succession, recording each of the readings as they're taken. Since these clamps output 1 milliamp per amp, the milliamp readings shown on the display are the actual phase current readings in amps.

Figure 5. Output current reading without using the low pass filter.


Figure 6. Output current reading with low pass filter enabled.

Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the ac voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter is turned on, the meter will be in the 600 mV manual range mode.
  • Place the clamp around each of the output phase cables in succession, recording each of the readings as they are taken (see Figure 6). Since these clamps output 1 millivolt per amp, the millivolt readings shown on the 87-V display are the actual phase current readings in amps. This measurement would not be possible without the low pass filter (see Figure 5).

Motor speed (Output frequency using current as a reference)

For motors that pull at least 20 amps of running current, motor speed can be determined by taking a frequency measurement with current clamps. Until now, noise issues have prevented accurate readings using hall effect type clamps. Here's how the low pass filter makes it possible.

Motor speed using a Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the ac voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter has been turned on, the meter will be in the 600 mV manual range mode.
  • Place the clamp around one of the output phase cables. Verify that the multimeter is reading a current of at least 20 amps (20 mV in the display).
  • Press the Hz button. The readings now display the motor speed as a frequency measurement.

Motor speed using a transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A AC function.
  • Place the clamp around one of the output phase cables. Verify that the multimeter is reading a current of at least 20 amps (20mA in the display).
  • Press the Hz button. The readings now display the motor speed as a frequency measurement.

DC Bus measurements

A healthy dc bus is a must for a properly operating motor drive. If the bus voltage is incorrect or unstable, the converter diodes or capacitors may be starting to fail. The DC bus voltage should be approximately 1.414 times the phase to phase input voltage. For a 480 volt input, the DC bus should be approximately 679 VDC. The DC bus is typically labeled as DC+, DC- or B+, Bon the drive terminal strip. To measure the DC bus voltage:

  • Select the dc voltage function.
  • Connect the black probe to either the DC- or B- terminal.
  • Connect the red probe to the DC+ or B+ terminal. The bus voltage should agree with the example mentioned above and be relatively stable. To check the amount of ac ripple on the bus, switch the 7V's function switch to the vac function. Some small drives don't allow external access to the DC bus measurement without disassembling the drive. If you can't access the DC bus, use the peak min max function on the multimeter to measure the dc bus voltage via the output voltage signal.
  • Plug the black test lead into the common jack and the red test lead into the V/½ jack.
  • Select the AC voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the min/max button.
  • Press the (Peak min/max) button.
  • The displayed reading in Peak min/max will be the DC bus voltage.

Click on a category to view a selection of compatible accessories with the Fluke 28-II TRMS Industrial Multimeter with IP67 Rating.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke C101 Hard Carrying Case C101
Compatible with a vareity of Fluke industrial test tools. Additionally, this hard carrying case features a foam interior.




Fluke C550 Premium Tool Bag C550
Tool Bag with steel reinforced frame.




Fluke C125 Soft Meter Case for Fluke Multimeters C125
Soft zippered carrying case with detachable external pouch. To be used with the 120-series, multimeters and testers.




Fluke C37XT Protective EVA Hard Tool Case, 10.9 x 4.7" C37XT
Durable and high quality, this 10.9 x 4.7" (277 x 119 mm) tool case is designed to fit most multimeters and similarly sized tools. Made from 600D EVA foam, this case features hinged dividers, additional pockets, straps, space for many accessories, and secures your tools with adjustable straps.




Fluke i200 AC Current Clamp I200
A single range 200 A clamp-on AC current clamp with current output via safety shrouded banana plugs. It is compatible with most Fluke multimeters or any other current measurement device that accepts shrouded banana plugs.




Fluke i3000s AC Current Clamp I3000S
3000A AC current clamp with BNC terminated lead




Fluke i1010 AC/DC Current Clamp I1010
Highly reliable, measures 1 to 1000 A, and provides accurate current reading without breaking the circuit. This clamp measures both AC and DC with a large jaw, battery-powered Hall-effect probe that gives access to difficult to reach areas.




Fluke i2000 FLEX Flexible AC Current Clamp I2000-FLEX
Utilizing the Rogowski principle, the clamp can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders, or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.




Fluke i410 AC/DC Current Clamp I410
The current clamp expands the functionality of digital multimeters and measures up to 400 amps for both AC and DC currents. The large clamp claw gives you access to difficult to reach areas.




Fluke i400 AC Current Clamp, 400 A AC, CAT IV 600 V/CAT III 1000 V I400
Compatible with digital multimeters, this current clamp measures up to 400 A AC and features a 1 mA/A output that guarantees easy reading on your meter. In addition, this clamp provides precise current measurements without breaking electric circuits, helping you measure safely with industry-standard safety ratings.




Fluke L206 Deluxe LED Hat Light L206
Three super bright white LEDs never burn out attach to hard hat, baseball cap, or panel door.




Fluke LVD2 Volt Light, Non Contact Voltage Detector & LED flashlight LVD2
Non-contact AC voltage detector and LED flashlight includes dual sensitivity turning blue 1" to 5" for the source and red at the source.




Fluke L210 Probe Light Kit L210
Comes in a small and rugged design, this probe light kit liberates the users' hands for work. Additionally, it features a bright white LED and fits between the modular test probe and test lead.




Fluke L215 SureGrip Kit with probe light and probe extender L215
Ideal for high-energy environments. Additionally, this kit comes equipped with a probe extender and probe light, which allows users to illuminate those hard-to-reach areas.




Fluke TL220 Suregrip Industrial Test Lead Set TL220
Includes the Fluke AC220, Fluke TP220, and Fluke TL224.




Fluke TL223 SureGrip Electrical Test Lead Set TL223
Designed for your comfort so you can focus on taking accurate measurements, this handy all-in-one kit comes equipped with a SureGrip alligator clip set, slim-reach test probes (flat bladed), and SureGrip silicone test lead set.




Fluke TL71 Premium Right Angle Test Lead Set TL71
Comfort grip probes with flexible silicone-insulated, right-angle test leads. They are heat and cold resistant, with a safety rating of CAT II 1000 V, 10 A.




Fluke TLK-225 SureGrip Master Accessory Set TLK-225
Perfect replacement kit provides flexibility and comfort with all SureGrip™ leads and probes in a convenient six pocket, roll-up pouch.




Fluke 80K-15 High Voltage Probe 80K-15
Designed to extend the voltage measuring capability of an AC/DC voltmeter to 15,000 V peak AC or DC Overvoltage Category I. The probe provides high accuracy when used with a voltmeter having 10 MΩ input impedance. Intended for low energy applications.




Fluke 80K-40 High Voltage Probe 80K-40
Designed to extend the voltage measuring capability of an AC/DC voltmeter to 40,000 V peak AC or DC Overvoltage Category I. The probe provides high accuracy when used with a voltmeter having 10 MΩ input impedance. Intended for low energy applications.




Fluke 80K-6 KV High Voltage Probe 80K-6
Designed to extend the voltage measuring capability of an AC/DC voltmeter to 6000 V peak AC or DC Overvoltage Category I. The probe provides high accuracy when used with a voltmeter having 10 MΩ input impedance. Intended for low energy applications.




Fluke AC285 SureGrip Alligator Clips AC285
Designed to improve steadiness in slippery hands, and is for use with TL222 and TL224 test leads. Rubber over-molded surfaces and finger-hugging curves give a comfortable, reliable grip so you can focus on making an accurate measurement.




Fluke 80AK-A Thermocouple Adapter 80AK-A
Designed to adapt K type thermocouples mini-connector to dual shrouded banana plug inputs. Additionally, it is ideal for low voltage applications below 30 V AC and 60 V DC.




Fluke 80PK-1 Bead Probe 80PK-1
A K type thermocouple ideal for general purpose applications.




Fluke 80PK-27 SureGrip Industrial Surface Temperature Probe 80PK-27
Compatible with any temperature measuring instrument that accepts type K thermocouples features a miniature connector input and a cold reference junction compensation. Additionally, this industrial surface temperature probe is ideal for surfaces in rugged environments.




Fluke 80PK-3A Surface Temperature Probe 80PK-3A
Compatible with any temperature measuring instrument that accepts type K thermocouples and features a miniature connector input. Additionally, this surface temperature probe is ideal for measuring the temperature of flat or slightly convex surfaces, with an exposed junction to allow direct contact with the surface being measured.




Fluke 80PK-8 Pipe Clamp Temperature Probe 80PK-8
Uses Type-K thermocouple for fast temperature and superheat measurements of pipe surfaces. Designed to reliably measure the temperature of pipes ¼" (6 mm) to 1⅜" (35 mm) in diameter, at temperatures between -20 and 300°F (-29 and 149°C), while retaining a long service life.




Fluke 80PK-9 General Purpose Probe 80PK-9
Featuring a general purpose type-K thermocouple probe for surface, air and non-caustic gases. It has a measuring range of -40 to 260°C.




Fluke 80PK-EXT Extension Wire Kit 80PK-EXT
Extension kit for type K thermocouple wires. Includes 3m of thermocouple wire and a pair of male/female mini-connectors.




Fluke 80T-150U Universal Temperature Probe 80T-150UA
A self-contained temperature-to-voltage converter, this probe is designed to provide a direct temperature reading when it is connected to any high impedance DMM capable of 1 mV resolution, and at least a 300-count full-scale readout capability.




Fluke 80TK Thermocouple Module 80TK
Thermocouple converter that accepts the output of any K-type thermocouple and converts it to 1 mV per degree (Celsius or Fahrenheit).




Ask a question about Fluke 28-II TRMS Industrial Multimeter with IP67 Rating

Customer Reviews for the Fluke 28-II

Fluke 28-II Offers

Features

  • 10,000µF capacitance range
  • Frequency measurement to 200kHz
  • True-RMS AC voltage and current measurements on non-linear signals
  • Extended AC voltage bandwidth; 15Hz to 20kHz
  • Resistance, continuity and diode test
  • Auto and manual ranging for maximum flexibility
  • Min/Max and average recording to capture variations automatically
  • Peak min/max
  • Relative mode to remove test lead resistance from low ohms measurements
  • Unique function for accurate voltage and frequency measurements on adjustable speed motor rives and other electrically noisy equipment
  • Built-in thermometer conveniently allows you to take temperature measurements
  • Hi resolution 20,000-count display mode
  • Large display digits and two-level backlight
  • Backlit keypad buttons allow for easy visibility in lowlit areas
  • Withstands 8000V spikes caused by load switching and faults
  • Reversible holster for added protection when not in use
  • Designed to withstand 3m drop
  • IP67 waterproof and dustproof protection, completely sealed for use in harsh environments
  • Cat. IV 600V, Cat. III 1000V safety ratings

Fluke 28-II Specifications

Voltage Range 0.1mV to 1000V AC/DC
Voltage Accuracy AC: ±0.7% rdg. +4 dgt.
DC: ±0.05% rdg. +1 dgt.
Current Range 0.1µA to 10A AC/DC
Current Accuracy AC: ±1.0% rdg. +2 dgt.
DC: ±0.2% rdg. +4 dgt.
Resistance Range 0.1Ω to 50MΩ
Capacitance Range 1nF to 9999ΩF
Frequency Range 0.5Hz to 199.99kHz
Temperature Range -200 to 1090°C
Click here for complete specifications on the Fluke 28-II

What's included with the Fluke 28-II

  • 28-II Industrial Multimeter
  • Holster
  • Test leads
  • Alligator clips
  • 80BK-A Temperature probe
  • Manual
  • CD-ROM
  • 3 x AA batteries (installed)

Multimeter measurements on adjustable speed drives

In the past, motor repair meant dealing with traditional three-phase motor failures that were largely the result of water, dust, grease, failed bearings, misaligned motor shafts, or just plain old age. But motor repair has changed in a big way with the introduction of electronically controlled motors, more commonly referred to as adjustable speed drives (ASDs). These drives present a unique set of measurement problems that can vex the most seasoned pro. Thanks to new technology, now for the first time you can take accurate electrical measurements with a DMM during the installation and maintenance of a drive and diagnose bad components and other conditions that may lead to premature failure.

Troubleshooting philosophy

Technicians use many different methods to troubleshoot an electrical circuit, and a good troubleshooter will always find the problem - eventually. The trick is tracking it down quickly and keeping downtime to a minimum. The most efficient troubleshooting procedure begins at the motor and then works systematically back to the electrical source, looking for the most obvious problems first. A lot of time and money can be wasted replacing perfectly good parts when the problem is simply a loose connection. As you go, take care to take accurate measurements. Nobody takes inaccurate measurements on purpose, but it's easy to do, especially when working in a high-energy, noisy environment like an ASD. Likewise, choosing the right test tools for troubleshooting the drive, the motor, and the connections are of utmost importance. This is especially true when taking voltage, frequency, and current measurements on the output side of the motor drive. But until now, there hasn't been a digital multimeter on the market able to accurately measure ASDs. Incorporates a selectable low pass filter* that allows for accurate drive output measurements that agree with the motor drive controller display indicator. Now, technicians won't have to guess whether the drive is operating correctly and delivering the correct voltage, current, or frequency for a given control setting.

Drive measurements

Input side measurements

Any good quality True RMS multimeter can verify proper input power to an ASD. The input voltage readings should be within 1% of one another when measured from phase to phase with no load. A significant unbalance may lead to erratic drive operation and should be corrected when discovered.

Output side measurements

On the flip side, a regular True RMS multimeter can't reliably read the output side of a pulse width modulated (PWM) motor drive, because the ASD applies pulse width modulated nonsinusoidal voltage to the motor terminals. A True RMS DMM reads the heating effect of the non-sinusoidal voltage applied to the motor, while the motor controller's output voltage reading only displays the RMS value of the fundamental component (typically from 30 Hz to 60 Hz). The causes of this discrepancy are bandwidth and shielding. Many of today's True RMS digital multimeters have bandwidths out to 20 kHz or more, causing them to respond not only to the fundamental component, which is what the motor responds to but to all of the high-frequency components generated by the PWM drive. And if the DMM isn't shielded for high-frequency noise, the drive controller's high noise levels make the measurement discrepancies even more extreme. With the bandwidth and shielding issues combined, many True RMS meters display readings as much as 20 to 30% higher than what the drive controller is indicating. The incorporated selectable low pass filter allows troubleshooters to take accurate voltage, current, and frequency measurements on the output side of the drive at either the drive itself or the motor terminals. With the filter selected, the readings for both voltage and frequency (motor speed) should agree with the associated drive control display indications, if available. The low pass filter also allows for accurate current measurements when used with Hall-effect type clamps. All of these measurements are especially helpful when taking measurements at the motor location when the drive's displays are not in view.

Taking safe measurements

Before taking any electrical measurements, be sure you understand how to take them safely. No test instrument is completely safe if used improperly, and many test instruments are not appropriate for testing adjustable speed drives. Also, make sure to use the appropriate personal protective equipment (PPE) for your specific working environment and measurements. If at all possible, never work alone.

Safety ratings for electrical test equipment

ANSI and the International Electrotechnical Commission (IEC) are the primary independent organizations that define safety standards for test equipment manufacturers. The IEC 61010 second edition standard for test equipment safety states two basic parameters: a voltage rating and a measurement category rating. The voltage rating is the maximum continuous working voltage the instrument is capable of measuring. The category ratings depict the measurement environment expected for a given category. Most three-phase ASD installations would be considered a CAT III measurement environment, with power supplied from either 480V or 600V distribution systems. When using a DMM for measurements on these high-energy systems, make sure it's rated at a minimum for CAT III 600V and preferably for CAT IV 600V/CAT III 1000V. The category rating and voltage limit are typically found on the front panel, at the input terminals. Dual-rated CAT IV 600V and CAT III 1000V. Refer to the ABC's of DMM Safety* from Fluke for additional information on category ratings and taking safe measurements.

How to take measurements

Now let's put the multimeter to the test. The measurements in the following procedure are designed to be made on a 480 volt 3 phase drive control at the control panel terminal strips. These procedures would also be valid for lower voltage 3 phase drives powered by either single or 3 phase supply voltages. For these tests, the motor is running at 50 Hz.

Input voltage

To measure the ac voltage supply to the input side of the drive at the drive:

  • Select the ac voltage function.
  • Connect the black probe to one of the three phase input terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase input terminals and record the reading.
  • Leaving the black probe on the reference phase now move the red probe to the third phase input and record this reading.
  • Make sure there's no more than a 1% difference between these two readings.

Input current

Measuring the input current generally requires a current clamp accessory. In most cases, either the input current exceeds the maximum current measurable by the current function, or it isn't practical to "break the circuit" to take an in-line series current measurement. Regardless of clamp type, insure that all readings are within 10% of each other for proper balance.

Transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A AC function.
  • Place the clamp around each of the input supply phase cables in succession, recording each of the readings as they are taken. Since these clamps output one milliamp per amp, the milliamp readings shown on the display are the actual phase current readings in amps.

Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the AC voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter is enabled, the meter will be in the 600 mV manual range mode.
  • Place the clamp around each of the input supply phase cables in succession, recording each of the readings as they are taken. Since these clamps output one millivolt per amp, the millivolt readings shown on the display are the actual phase current readings in amps.

Figure 1. Output voltage reading without using the low pass filter.


Figure 2. Output voltage reading with low pass filter enabled.

Output voltage

To measure the AC output voltage at either the drive or the motor terminals:

  • Plug the black test lead into the common jack and the red test lead into the V/W jack.
  • Select the AC voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the yellow button to enable the low pass filter. Now record the reading.
  • Leaving the black probe on the reference phase, now move the red probe to the third phase output voltage or motor terminal and record this reading.
  • Make sure that there's no more than a 1% difference between these two readings (see Figure 2). The readings should also agree with the controller display, panel if available.
  • If the low pass filter isn't enabled, the output voltage readings may be 10 to 30% higher, as on a regular DMM (see Figure 1).

Figure 3. Output frequency (motor speed) without the low pass filter.


Figure 4. Output frequency (motor speed) using the low pass filter.

Motor speed (Output frequency using voltage as a reference)

To determine motor speed, simply take a frequency measurement while using the low pass filter. The measurement can be made between any two of the phase voltage or motor terminals.

  • Plug the black test lead into the common jack and the red test lead into the V/W jack.
  • Select the ac voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the yellow button to enable the low pass filter.
  • Press the Hz button. The displayed reading in hertz will be the motor speed (see Figure 3). This measurement couldn't be made successfully without the low pass filter (see Figure 4).

Output current

TAs with input current, measuring the output current generally requires a current clamp accessory. Once again, regardless of clamp type, insure that all readings are within 10% of each other for proper balance.

Transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A ac function.
  • Place the clamp around each of the output phase cables in succession, recording each of the readings as they're taken. Since these clamps output 1 milliamp per amp, the milliamp readings shown on the display are the actual phase current readings in amps.

Figure 5. Output current reading without using the low pass filter.


Figure 6. Output current reading with low pass filter enabled.

Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the ac voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter is turned on, the meter will be in the 600 mV manual range mode.
  • Place the clamp around each of the output phase cables in succession, recording each of the readings as they are taken (see Figure 6). Since these clamps output 1 millivolt per amp, the millivolt readings shown on the 87-V display are the actual phase current readings in amps. This measurement would not be possible without the low pass filter (see Figure 5).

Motor speed (Output frequency using current as a reference)

For motors that pull at least 20 amps of running current, motor speed can be determined by taking a frequency measurement with current clamps. Until now, noise issues have prevented accurate readings using hall effect type clamps. Here's how the low pass filter makes it possible.

Motor speed using a Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the ac voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter has been turned on, the meter will be in the 600 mV manual range mode.
  • Place the clamp around one of the output phase cables. Verify that the multimeter is reading a current of at least 20 amps (20 mV in the display).
  • Press the Hz button. The readings now display the motor speed as a frequency measurement.

Motor speed using a transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A AC function.
  • Place the clamp around one of the output phase cables. Verify that the multimeter is reading a current of at least 20 amps (20mA in the display).
  • Press the Hz button. The readings now display the motor speed as a frequency measurement.

DC Bus measurements

A healthy dc bus is a must for a properly operating motor drive. If the bus voltage is incorrect or unstable, the converter diodes or capacitors may be starting to fail. The DC bus voltage should be approximately 1.414 times the phase to phase input voltage. For a 480 volt input, the DC bus should be approximately 679 VDC. The DC bus is typically labeled as DC+, DC- or B+, Bon the drive terminal strip. To measure the DC bus voltage:

  • Select the dc voltage function.
  • Connect the black probe to either the DC- or B- terminal.
  • Connect the red probe to the DC+ or B+ terminal. The bus voltage should agree with the example mentioned above and be relatively stable. To check the amount of ac ripple on the bus, switch the 7V's function switch to the vac function. Some small drives don't allow external access to the DC bus measurement without disassembling the drive. If you can't access the DC bus, use the peak min max function on the multimeter to measure the dc bus voltage via the output voltage signal.
  • Plug the black test lead into the common jack and the red test lead into the V/½ jack.
  • Select the AC voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the min/max button.
  • Press the (Peak min/max) button.
  • The displayed reading in Peak min/max will be the DC bus voltage.

Click on a category to view a selection of compatible accessories with the Fluke 28-II TRMS Industrial Multimeter with IP67 Rating.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke C101 Hard Carrying Case C101
Compatible with a vareity of Fluke industrial test tools. Additionally, this hard carrying case features a foam interior.




Fluke C550 Premium Tool Bag C550
Tool Bag with steel reinforced frame.




Fluke C125 Soft Meter Case for Fluke Multimeters C125
Soft zippered carrying case with detachable external pouch. To be used with the 120-series, multimeters and testers.




Fluke C37XT Protective EVA Hard Tool Case, 10.9 x 4.7" C37XT
Durable and high quality, this 10.9 x 4.7" (277 x 119 mm) tool case is designed to fit most multimeters and similarly sized tools. Made from 600D EVA foam, this case features hinged dividers, additional pockets, straps, space for many accessories, and secures your tools with adjustable straps.




Fluke i200 AC Current Clamp I200
A single range 200 A clamp-on AC current clamp with current output via safety shrouded banana plugs. It is compatible with most Fluke multimeters or any other current measurement device that accepts shrouded banana plugs.




Fluke i3000s AC Current Clamp I3000S
3000A AC current clamp with BNC terminated lead




Fluke i1010 AC/DC Current Clamp I1010
Highly reliable, measures 1 to 1000 A, and provides accurate current reading without breaking the circuit. This clamp measures both AC and DC with a large jaw, battery-powered Hall-effect probe that gives access to difficult to reach areas.




Fluke i2000 FLEX Flexible AC Current Clamp I2000-FLEX
Utilizing the Rogowski principle, the clamp can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders, or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.




Fluke i410 AC/DC Current Clamp I410
The current clamp expands the functionality of digital multimeters and measures up to 400 amps for both AC and DC currents. The large clamp claw gives you access to difficult to reach areas.




Fluke i400 AC Current Clamp, 400 A AC, CAT IV 600 V/CAT III 1000 V I400
Compatible with digital multimeters, this current clamp measures up to 400 A AC and features a 1 mA/A output that guarantees easy reading on your meter. In addition, this clamp provides precise current measurements without breaking electric circuits, helping you measure safely with industry-standard safety ratings.




Fluke L206 Deluxe LED Hat Light L206
Three super bright white LEDs never burn out attach to hard hat, baseball cap, or panel door.




Fluke LVD2 Volt Light, Non Contact Voltage Detector & LED flashlight LVD2
Non-contact AC voltage detector and LED flashlight includes dual sensitivity turning blue 1" to 5" for the source and red at the source.




Fluke L210 Probe Light Kit L210
Comes in a small and rugged design, this probe light kit liberates the users' hands for work. Additionally, it features a bright white LED and fits between the modular test probe and test lead.




Fluke L215 SureGrip Kit with probe light and probe extender L215
Ideal for high-energy environments. Additionally, this kit comes equipped with a probe extender and probe light, which allows users to illuminate those hard-to-reach areas.




Fluke TL220 Suregrip Industrial Test Lead Set TL220
Includes the Fluke AC220, Fluke TP220, and Fluke TL224.




Fluke TL223 SureGrip Electrical Test Lead Set TL223
Designed for your comfort so you can focus on taking accurate measurements, this handy all-in-one kit comes equipped with a SureGrip alligator clip set, slim-reach test probes (flat bladed), and SureGrip silicone test lead set.




Fluke TL71 Premium Right Angle Test Lead Set TL71
Comfort grip probes with flexible silicone-insulated, right-angle test leads. They are heat and cold resistant, with a safety rating of CAT II 1000 V, 10 A.




Fluke TLK-225 SureGrip Master Accessory Set TLK-225
Perfect replacement kit provides flexibility and comfort with all SureGrip™ leads and probes in a convenient six pocket, roll-up pouch.




Fluke 80K-15 High Voltage Probe 80K-15
Designed to extend the voltage measuring capability of an AC/DC voltmeter to 15,000 V peak AC or DC Overvoltage Category I. The probe provides high accuracy when used with a voltmeter having 10 MΩ input impedance. Intended for low energy applications.




Fluke 80K-40 High Voltage Probe 80K-40
Designed to extend the voltage measuring capability of an AC/DC voltmeter to 40,000 V peak AC or DC Overvoltage Category I. The probe provides high accuracy when used with a voltmeter having 10 MΩ input impedance. Intended for low energy applications.




Fluke 80K-6 KV High Voltage Probe 80K-6
Designed to extend the voltage measuring capability of an AC/DC voltmeter to 6000 V peak AC or DC Overvoltage Category I. The probe provides high accuracy when used with a voltmeter having 10 MΩ input impedance. Intended for low energy applications.




Fluke AC285 SureGrip Alligator Clips AC285
Designed to improve steadiness in slippery hands, and is for use with TL222 and TL224 test leads. Rubber over-molded surfaces and finger-hugging curves give a comfortable, reliable grip so you can focus on making an accurate measurement.




Fluke 80AK-A Thermocouple Adapter 80AK-A
Designed to adapt K type thermocouples mini-connector to dual shrouded banana plug inputs. Additionally, it is ideal for low voltage applications below 30 V AC and 60 V DC.




Fluke 80PK-1 Bead Probe 80PK-1
A K type thermocouple ideal for general purpose applications.




Fluke 80PK-27 SureGrip Industrial Surface Temperature Probe 80PK-27
Compatible with any temperature measuring instrument that accepts type K thermocouples features a miniature connector input and a cold reference junction compensation. Additionally, this industrial surface temperature probe is ideal for surfaces in rugged environments.




Fluke 80PK-3A Surface Temperature Probe 80PK-3A
Compatible with any temperature measuring instrument that accepts type K thermocouples and features a miniature connector input. Additionally, this surface temperature probe is ideal for measuring the temperature of flat or slightly convex surfaces, with an exposed junction to allow direct contact with the surface being measured.




Fluke 80PK-8 Pipe Clamp Temperature Probe 80PK-8
Uses Type-K thermocouple for fast temperature and superheat measurements of pipe surfaces. Designed to reliably measure the temperature of pipes ¼" (6 mm) to 1⅜" (35 mm) in diameter, at temperatures between -20 and 300°F (-29 and 149°C), while retaining a long service life.




Fluke 80PK-9 General Purpose Probe 80PK-9
Featuring a general purpose type-K thermocouple probe for surface, air and non-caustic gases. It has a measuring range of -40 to 260°C.




Fluke 80PK-EXT Extension Wire Kit 80PK-EXT
Extension kit for type K thermocouple wires. Includes 3m of thermocouple wire and a pair of male/female mini-connectors.




Fluke 80T-150U Universal Temperature Probe 80T-150UA
A self-contained temperature-to-voltage converter, this probe is designed to provide a direct temperature reading when it is connected to any high impedance DMM capable of 1 mV resolution, and at least a 300-count full-scale readout capability.




Fluke 80TK Thermocouple Module 80TK
Thermocouple converter that accepts the output of any K-type thermocouple and converts it to 1 mV per degree (Celsius or Fahrenheit).




Ask a question about Fluke 28-II TRMS Industrial Multimeter with IP67 Rating

Customer Reviews for the Fluke 28-II

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.
Calibration Lab