Record temperature and relative humidity (within 2.5% accuracy) with this temperature/humidity data logger. With integrated sensors, this logger is for use in indoor environments and features an easy-to view LCD as well as a large memory capacity (84,650 measurements).
Record temperature and relative humidity (within 2.5% accuracy) with this temperature/humidity data logger. With integrated sensors, this logger is for use in indoor environments and features an easy-to view LCD as well as a large memory capacity (84,650 measurements).
Records temperature and relative humidity (within 2.5% accuracy) in indoor environments with the integrated sensor, this logger is ideal for monitoring occupant comfort in office buildings, tracking food storage conditions in warehouses, and logging temperature trends in server rooms.
This data logger requires a compatible mobile device or Windows computer and the HOBOconnect app.
Features
In what environment does this data logger operate?
Supported measurements
Applications
Download the mobile App
With so many choices of data loggers available today, it can be challenging to know which one is right for your application. There is a range of different types of data logging devices available, including:
Stand-alone
Stand-alone data loggers are compact and easy to set up and deploy. You have a choice of low-cost, stand-alone loggers with internal sensors for measurements at the logger location, or multi-channel loggers with external sensors for monitoring at some distance from the logger. All stand-alone loggers communicate with a PC or Mac via USB.
Web-based
Web-based systems enable real-time, remote access to your data via cellular, Wi-Fi, or Ethernet communications. They can be configured with any combination of external smart sensors, and have been designed with an industrial-grade, tamper-proof enclosure. This enables them to be used in indoor HVAC/R monitoring projects, as well as outdoor projects such as rooftop HVAC/R system monitoring.
Wireless sensor
Wireless data nodes are ideal for centralized, on-site monitoring of building performance. By combining data logger and transmitter in one, data nodes transmit high-accuracy, real-time data from dozens of points to a central PC or Mac. This eliminates the need to manually retrieve and offload individual data loggers, saving time and money. Should an obstruction block the wireless flow of data, these MESH networking devices automatically reroute the path to the receiver – all without manual intervention.
Once you know what parameters you'll be measuring, you need to make sure to choose a data logger that provides the accuracy you need. Accuracy specifications vary widely among different data loggers, so when shopping around be sure to look for accuracy charts that indicate accuracy over an entire measurement range – not just a single value. As a general rule, it's good to look for a data logger that will provide at least twice the accuracy of what your application requires.
Another important factor is data logger resolution, which refers to the number of increments of a value a data logger is capable of reporting. This is important if you plan to deploy a logger for months at a time, or want the logger to record data in 10-second intervals. You should also ask about a logger's response time.
If you're unsure about your application's accuracy and resolution requirements, an experienced supplier should be able to help you determine which product will meet your needs.
All data loggers use software for setup and configuration, but some loggers require more customization than others. User-friendly loggers can be set up and launched by someone with no training in electrical wiring or programming.
Depending on the type of data logger, the user can connect to a PC or mobile device via a USB connection, cellular, Wi-Fi, Ethernet or Bluetooth Low Energy (BLE) technology. The accompanying logger software automatically recognizes the device and asks a series of configuration questions. The user simply chooses a sampling interval and selects an immediate or designated future launch time. There is no wiring or programming involved, even for multi-component weather stations.
Ask about the software that comes with the data logger. Applications are generally Windows and MAC-based, and highly intuitive so the learning curve is minimal. The software should enable you to quickly and easily perform tasks such as setting configuration parameters, designating launch times, and offloading data with point-and-click simplicity. For BLE-enabled monitoring, configuring the loggers and managing data simply requires downloading a free app to your mobile device.
Check the software's graphing and analysis capabilities, including whether you can combine graphs to compare data between sites, or if you can view all of a site's data clearly in a single graph. Depending on the scope and type of data, the manufacturer may also have special application-specific software available.
There are a number of other capabilities to look for. For example, the software should allow you to select a range of data in a graph, and display the maximum, minimum, average, and standard deviation for the measurements in that range. It should also allow you to save data analysis projects for future use.
Finally, since data often need to be passed into other software programs such as spreadsheets or modeling programs, make sure that the logger software allows you to quickly and easily export data. Also be sure that you can print graphs and tables, which is especially important for documentation purposes.
Data loggers are generally extremely low-power devices. However, because they are used in a variety of environmental conditions and sample at different rates, battery life can vary widely. As a general rule of thumb, make sure the data logger you select has a battery life of at least one year.
Most logger manufacturers' software will indicate when the logger's battery power is getting low. You may also want to ask your supplier about whether or not the data logger battery is user-replaceable, as this can eliminate the time and expense of having to ship the logger back to the manufacturer for battery replacement.
The storage capacity of a data logger can vary widely between models. In general, be sure to buy a logger that provides enough on-board memory to cover the sampling rate and deployment duration you need. If you are unsure of how often you will be able to offload and relaunch your deployed data loggers, it may be best to buy a logger with more memory to prevent any gaps in data.
Temperature Sensor | |
Range | -4 to 158°F (-20 to 70°C) |
Accuracy | ±0.38°F from 32 to 122°F (±0.21°C from 0 to 50°C) |
Resolution | -0.04°F at 77°F (0.024°C at 25°C) |
Response Time | 4 minutes in air moving 1 m/s (2.2 mph) |
Drift | <0.18°F (0.1°C) per year |
RH Sensor | |
Range | 1 to 95% (non-condensing) |
Accuracy | ±2.5% from 10 to 90% typical to a maximum of ±3.5% including hysteresis at 77°F (25°C); below 10% and above 90% ±5% typical |
Resolution | 0.01% |
Response Time | 10 seconds to 90% in airflow of 1 m/s (2.2 mph) |
Drift | <1% per year typical |
Logger | |
Operating Range | Logging: -4 to 158°F (-20 to 70°C); 0 to 95% RH (non-condensing) Launch/Readout: 32 to 122°F (0 to 50°C) per USB specification |
Logging | Rate: 1 second to 18 hours, 12 minutes, 15 seconds Modes: Normal, Burst or Statistics |
Modes | Memory: Wrap when full or stop when full Start: Immediately, push button, date and time or next interval Stop: When memory full, push button, or date and time Restart: Push button |
Time Accuracy | ±1 minute per month at 77°F (25°C) |
Battery | Life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater Type: 1 x 3 V CR2032 lithium battery |
Environmental Rating | IP50 |
Dimensions | 1.44 x 3.34 x 0.9" (3.66 x 8.48 x 2.29 cm) |
Weight | 1.06 oz (30 g) |
Click on a category to view a selection of compatible accessories with the Onset HOBO UX100-011A Temperature/Humidity Data Logger, 2.5% accuracy.
With so many choices of data loggers available today, it can be challenging to know which one is right for your application. There is a range of different types of data logging devices available, including:
Stand-alone
Stand-alone data loggers are compact and easy to set up and deploy. You have a choice of low-cost, stand-alone loggers with internal sensors for measurements at the logger location, or multi-channel loggers with external sensors for monitoring at some distance from the logger. All stand-alone loggers communicate with a PC or Mac via USB.
Web-based
Web-based systems enable real-time, remote access to your data via cellular, Wi-Fi, or Ethernet communications. They can be configured with any combination of external smart sensors, and have been designed with an industrial-grade, tamper-proof enclosure. This enables them to be used in indoor HVAC/R monitoring projects, as well as outdoor projects such as rooftop HVAC/R system monitoring.
Wireless sensor
Wireless data nodes are ideal for centralized, on-site monitoring of building performance. By combining data logger and transmitter in one, data nodes transmit high-accuracy, real-time data from dozens of points to a central PC or Mac. This eliminates the need to manually retrieve and offload individual data loggers, saving time and money. Should an obstruction block the wireless flow of data, these MESH networking devices automatically reroute the path to the receiver – all without manual intervention.
Once you know what parameters you'll be measuring, you need to make sure to choose a data logger that provides the accuracy you need. Accuracy specifications vary widely among different data loggers, so when shopping around be sure to look for accuracy charts that indicate accuracy over an entire measurement range – not just a single value. As a general rule, it's good to look for a data logger that will provide at least twice the accuracy of what your application requires.
Another important factor is data logger resolution, which refers to the number of increments of a value a data logger is capable of reporting. This is important if you plan to deploy a logger for months at a time, or want the logger to record data in 10-second intervals. You should also ask about a logger's response time.
If you're unsure about your application's accuracy and resolution requirements, an experienced supplier should be able to help you determine which product will meet your needs.
All data loggers use software for setup and configuration, but some loggers require more customization than others. User-friendly loggers can be set up and launched by someone with no training in electrical wiring or programming.
Depending on the type of data logger, the user can connect to a PC or mobile device via a USB connection, cellular, Wi-Fi, Ethernet or Bluetooth Low Energy (BLE) technology. The accompanying logger software automatically recognizes the device and asks a series of configuration questions. The user simply chooses a sampling interval and selects an immediate or designated future launch time. There is no wiring or programming involved, even for multi-component weather stations.
Ask about the software that comes with the data logger. Applications are generally Windows and MAC-based, and highly intuitive so the learning curve is minimal. The software should enable you to quickly and easily perform tasks such as setting configuration parameters, designating launch times, and offloading data with point-and-click simplicity. For BLE-enabled monitoring, configuring the loggers and managing data simply requires downloading a free app to your mobile device.
Check the software's graphing and analysis capabilities, including whether you can combine graphs to compare data between sites, or if you can view all of a site's data clearly in a single graph. Depending on the scope and type of data, the manufacturer may also have special application-specific software available.
There are a number of other capabilities to look for. For example, the software should allow you to select a range of data in a graph, and display the maximum, minimum, average, and standard deviation for the measurements in that range. It should also allow you to save data analysis projects for future use.
Finally, since data often need to be passed into other software programs such as spreadsheets or modeling programs, make sure that the logger software allows you to quickly and easily export data. Also be sure that you can print graphs and tables, which is especially important for documentation purposes.
Data loggers are generally extremely low-power devices. However, because they are used in a variety of environmental conditions and sample at different rates, battery life can vary widely. As a general rule of thumb, make sure the data logger you select has a battery life of at least one year.
Most logger manufacturers' software will indicate when the logger's battery power is getting low. You may also want to ask your supplier about whether or not the data logger battery is user-replaceable, as this can eliminate the time and expense of having to ship the logger back to the manufacturer for battery replacement.
The storage capacity of a data logger can vary widely between models. In general, be sure to buy a logger that provides enough on-board memory to cover the sampling rate and deployment duration you need. If you are unsure of how often you will be able to offload and relaunch your deployed data loggers, it may be best to buy a logger with more memory to prevent any gaps in data.
Temperature Sensor | |
Range | -4 to 158°F (-20 to 70°C) |
Accuracy | ±0.38°F from 32 to 122°F (±0.21°C from 0 to 50°C) |
Resolution | -0.04°F at 77°F (0.024°C at 25°C) |
Response Time | 4 minutes in air moving 1 m/s (2.2 mph) |
Drift | <0.18°F (0.1°C) per year |
RH Sensor | |
Range | 1 to 95% (non-condensing) |
Accuracy | ±2.5% from 10 to 90% typical to a maximum of ±3.5% including hysteresis at 77°F (25°C); below 10% and above 90% ±5% typical |
Resolution | 0.01% |
Response Time | 10 seconds to 90% in airflow of 1 m/s (2.2 mph) |
Drift | <1% per year typical |
Logger | |
Operating Range | Logging: -4 to 158°F (-20 to 70°C); 0 to 95% RH (non-condensing) Launch/Readout: 32 to 122°F (0 to 50°C) per USB specification |
Logging | Rate: 1 second to 18 hours, 12 minutes, 15 seconds Modes: Normal, Burst or Statistics |
Modes | Memory: Wrap when full or stop when full Start: Immediately, push button, date and time or next interval Stop: When memory full, push button, or date and time Restart: Push button |
Time Accuracy | ±1 minute per month at 77°F (25°C) |
Battery | Life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater Type: 1 x 3 V CR2032 lithium battery |
Environmental Rating | IP50 |
Dimensions | 1.44 x 3.34 x 0.9" (3.66 x 8.48 x 2.29 cm) |
Weight | 1.06 oz (30 g) |
Click on a category to view a selection of compatible accessories with the Onset HOBO UX100-011A Temperature/Humidity Data Logger, 2.5% accuracy.