Multi-functional power and energy meters are customizable with a variety of modular I/O and communciation options to fit specific applications in order to provide the most versatile and cost-effective metering solution on the market.
Multi-functional power and energy meters are customizable with a variety of modular I/O and communciation options to fit specific applications in order to provide the most versatile and cost-effective metering solution on the market.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Commercial / Industrial Energy Meters category for similar products.
Or let's do a search and help you find what you need:
A multi-functional power and energy meter designed for facilities and energy professionals to monitor electrical systems, devices and consumption. Includes MODBUS RS485 and software. Optional analog & digital input, outputs, relay and Ethernet modules.
Compatible with different current transformers such as 5A, 1A, 80mA, 100mA, 200mA, 333mV output CT and Rogowski coil, the Acuvim II series may be used as data gathering devices for intelligent power distribution systems or plant automation systems. All monitored data is available via a digital RS485 communication port running Modbus RTU protocol. Ethernet and Profibus DP communication are also options.
The Acuvim-II Series does not offer data logging or have any onboard memory, for these features see the Acuvim-IIE and Acuvim-IIR.
Those looking for Time of Use (TOU) features should check out the Acuvim-IIE instead.
Those looking for a Revenue Grade Power Meter should look at the Acuvim-IIR instead.
Metering
Monitoring
Alarms
Limits can be set for up to 16 indicated parameters and can be set with
a specified time interval. If any input of the indicated parameters is over or under its setting limit and persists over the specified time interval, the event will be recorded with time stamps and trigger the Alarm DO output. The 16 indicated parameters can be selected from any of the 51
parameters available.
The Acuvim II Series is available in two mounting options:
The standard model is ANSI C39.1 Standard Compliant with a small size 96x96 outline.
The DIN Rail compatible units are DIN 43700 Standard Compliant. The Acuvim II series also offers an optional Remote LCD display.
Accuracy Acuvim-II |
Accuracy Acuvim-IIR/IIE/IIW |
Resolution | Range | |
---|---|---|---|---|
Voltage | 0.2% | 0.2% | 0.1V | 20V~1000kV |
Current | 0.2% | 0.2% | 0.1mA | 5mA~50000A |
Power | 0.5% | 0.2% | 1W | -9999MW~9999MW |
Reactive Power | 0.5% | 0.2% | 1var | 9999Mvar~9999Mvar |
Apparent Power | 0.5% | 0.2% | 1VA | 0~9999MVA |
Power Demand | 0.5% | 0.2% | 1W | -9999MW~9999MW |
Reactive Power Demand | 0.5% | 0.2% | 1var | -9999Mvar~9999Mvar |
Apparent Power Demand | 0.5% | 0.2% | 0.2% | 0~9999MVA |
Power Factor | 0.5% | 0.2% | 0.001 | -1.000~1.000 |
Frequency | 0.2% | 0.2% | 0.01Hz | 45.00~65.00Hz |
Energy Primary | 0.5% | 0.2% | 0.1kWh | 0-99999999.9kWh |
Energy Secondary | 0.5% | 0.2% | 0.001kWh | 0-999999.999kWh |
Reactive Energy Primary | 0.5% | 0.2% | 0.1kvarh | 0-99999999.9kvarh |
Reactive Energy Secondary | 0.5% | 0.2% | 0.001kvarh | 0-999999.999kvarh |
Apparent Energy Primary | 0.5% | 0.2% | 0.1kVAh | 0-99999999.9kVAh |
Apparent Energy Secondary | 0.5% | 0.2% | 0.001kVAh | 0-999999.999kVAh |
Harmonics | 1.0% | 1.0% | 0.1% | 0.0%~100.0% 20.0%~100.0% (IIR/IIE/IIW) |
Phase Angle | 2.0% | 2.0% | 0.1° | 0.0°~359.9° |
Unbalance Factor | 2.0% | 2.0% | 0.1% | 0.0%~100.0% |
Running Time | 0.01h | 0~9999999.99h |
Current Inputs (Each Channel) | |
---|---|
Nominal Current | 5A /1A |
Metering Range | 0~10A AC |
Withstand | 20Arms continuous, 100Arms for 1 second, non-recurring |
Burden | 0.05VA (typical) @ 5Arms |
Pickup Current | 0.1% of nominal |
Accuracy | 0.2% full scale |
Voltage Inputs (Each Channel) | |
Nominal Full Scale | 400V AC L-N, 690V AC L-L (+20%) |
Withstand | 1500V AC continuous 2500V AC, 50/60Hz for 1 minute |
Input Impedance | 2Mohm per phase |
Metering Frequency | 45Hz~65Hz |
Pickup Voltage | 10Vac (30 Vac for Acuvim IIR/IIE/IIW) |
Accuracy | 0.2% full scale |
Energy Accuracy (Acuvim IIR/IIE/IIW) | |
Active | According to IEC 62053-22: Class 0.2s According to ANSI C12.20: Class 0.2s |
Reactive (according to IEC 62053-23) | Class 2 |
Harmonic Resolution | |
Metered Value | Acuvim II: 31st harmonic Acuvim IIR/IIE/IIW: 63rd harmonic |
Control Power | |
Universal | AC or DC |
Operating Range | 100~415V AC, 50/60Hz 100~300V DC |
Burden | 5W |
Frequency | 50/60Hz |
Withstand | 3250V AC, 50/60Hz for 1 minute Installation Category III (Distribution) |
Low Voltage DC Control Power (Optional) | |
Operating Range | 20~60V DC |
Burden | 5W |
Rs-485 (standard)
MODBUS® RTU Protocol, 2-wire connection
1200~38400 baud rate
The second Rs-485 Port (Optional)
MODBUS® RTU Protocol, 2-wire connection
4800~38400 baud rate
Ethernet (Optional)
10M/100M BaseT
MODBUS® TCP/IP Protocol
Data Browsing through HTTP
Sending e-mail automatically
PROFI-BUs (Optional)
PROFIBUS-DP/V0 Protoco
Work as PROFIBUS slave, baud rate adaptive, up to 12M
Typical input bytes: 32, typical output bytes: 32
PROFIBUS standard according to EN 50170 vol.2
Category | Item | Parameters | Acuvim II | Acuvim IIR | Acuvim IIE | |
Metering | Real Time Metering | Phase Voltage | V1, V2, V3, Vlnavg | |||
Metering | Real Time Metering | Line Voltage | V12, V23, V31, Vllavg | |||
Metering | Real Time Metering | Current | I1, I2, I3, In, Iavg | |||
Metering | Real Time Metering | Power | P1, P2, P3, Psum | |||
Metering | Real Time Metering | Reactive Power | Q1, Q2, Q3, Qsum | |||
Metering | Real Time Metering | Apparent Power | S1, S2, S3, Ssum | |||
Metering | Real Time Metering | Power Factor | PF1, PF2, PF3, PF | |||
Metering | Real Time Metering | Frequency | F | |||
Metering | Real Time Metering | Load Features | Load Features | |||
Metering | Real Time Metering | Four Quadrant Powers | Four Quadrant Powers | |||
Metering | Energy & Demand | Energy | Ep_imp, Ep_exp, Ep_total, Ep_net | |||
Metering | Energy & Demand | Reactive Energy | Eq_imp, Eq_exp, Eq_total, Eq_net | |||
Metering | Energy & Demand | Apparent Energy | Es | |||
Metering | Energy & Demand | Demand | Dmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3 | |||
TOU | Time of Use | Energy/max demand | TOU, 4 Tariffs, 12 Seasons, 14 Schedules | |||
TOU | Daylight Savings Time | Two formats adjust | Month/Day/Hour/Minute Month/Week/First few weeks/Hour/Minute |
|||
Monitoring | Waveform Capture | voltage and current Waveform | Trigger, Manual, DI change, Sag/Dips, Swell, Over Current | |||
Monitoring | Power Quality | Voltage Unbalance Factor | U_unbl | |||
Monitoring | Power Quality | Current Unbalance Factor | I_unbl | |||
Monitoring | Power Quality | Voltage THD | THD_V1,THD_V2,THD_V3, THD_Vavg | |||
Monitoring | Power Quality | Current THD | THD_I1, THD_I2, THD_I, THD_Iavg | |||
Monitoring | Power Quality | Individual Harmonics | Harmonics 2nd to 63rd (31st for Acuvim II) | |||
Monitoring | Power Quality | Voltage Crest Factor | Crest Factor | |||
Monitoring | Power Quality | TIF | THFF | |||
Monitoring | Power Quality | Current K factor | K Factor | |||
Monitoring | Statistics | MAX with Time Stamp MIN with Time Stamp |
Each phase of V & l; Total of P, Q, S, PF & F; Demad of P,Q & S; Each phase THD of V & I; Unbalnce factor of V & I |
|||
Others | Alarm | Over/Under Limit Alarm | V, I, P, Q, S, PF, V_THD & I_THD each phase and total or average; Unbalance factor of V & I; load type; Analog Input of each channel | |||
Others | Power Quality Event logging | SAG/DIPS,SWELL | Voltage | |||
Others | Data Logging | Data Logging 1 Data Logging 2 Data Logging 3 |
F, V1/2/3/lnavg, V12/23/13/lavg, I1/2/3/n/avg, P1/2/3/sum,Q1/2/3/sum, S1/2/3/sum, PF1/2/3, PF, U_unbl, I_unbl, LoadType, Ep_imp, Ep_exp, Ep_total, Ep_net, Eq_imp, Eq_exp, Eq_total, Eq_net, Es, THD_V1/2/3/avg, THD_I1/2/3/avg, Harmonics2nd to 63rd, Crest Factor, THFF, K Factor, sequence and phaseangles, DI counter, AI, AO, Dmd P/Q/S, Dmd I1/2/3 | |||
Others | Onboard memory size | Memory | Bytes | - | 4MB | 4MB |
Others | Communication | RS485 Port, Half Duplex,Optical Isolated | Modbus®-RTU Protocol | |||
Others | Time | Real Time Clock | Year, Month, Date, Hour, Minute, Second | |||
Option Module | I/O Option | Switch Status (DI) | Digital Input (Wet) | Option | Option | Option |
Option Module | I/O Option | Power Supply for DI | 24 Vdc | Option | Option | Option |
Option Module | I/O Option | Relay Output (RO) | NO, Form A | Option | Option | Option |
Option Module | I/O Option | Digital Output (DO) | Photo-MOS | Option | Option | Option |
Option Module | I/O Option | Pulse Output (PO) | By using DO | Option | Option | Option |
Option Module | I/O Option | Analog Input (AI) | 0(4)~20mA, 0(1)~5V | Option | Option | Option |
Option Module | I/O Option | Analog Output (AO) | 0(4)~20mA, 0(1)~5V | Option | Option | Option |
Option Module | Communication | Ethernet | 10M/100M, Modbus-TCP, HTTP Webpage, Email | Option | Option | Option |
Option Module | Communication | Profibus-DP | Profibus-DP/V0 | Option | Option | Option |
Option Module | Communication | RS485 Module | Additional Modbus RTU | Option | Option | Option |
As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.
Click on a category to view a selection of compatible accessories with the Accuenergy Acuvim II Series of Intelligent Power/Energy Meters.
Accuracy Acuvim-II |
Accuracy Acuvim-IIR/IIE/IIW |
Resolution | Range | |
---|---|---|---|---|
Voltage | 0.2% | 0.2% | 0.1V | 20V~1000kV |
Current | 0.2% | 0.2% | 0.1mA | 5mA~50000A |
Power | 0.5% | 0.2% | 1W | -9999MW~9999MW |
Reactive Power | 0.5% | 0.2% | 1var | 9999Mvar~9999Mvar |
Apparent Power | 0.5% | 0.2% | 1VA | 0~9999MVA |
Power Demand | 0.5% | 0.2% | 1W | -9999MW~9999MW |
Reactive Power Demand | 0.5% | 0.2% | 1var | -9999Mvar~9999Mvar |
Apparent Power Demand | 0.5% | 0.2% | 0.2% | 0~9999MVA |
Power Factor | 0.5% | 0.2% | 0.001 | -1.000~1.000 |
Frequency | 0.2% | 0.2% | 0.01Hz | 45.00~65.00Hz |
Energy Primary | 0.5% | 0.2% | 0.1kWh | 0-99999999.9kWh |
Energy Secondary | 0.5% | 0.2% | 0.001kWh | 0-999999.999kWh |
Reactive Energy Primary | 0.5% | 0.2% | 0.1kvarh | 0-99999999.9kvarh |
Reactive Energy Secondary | 0.5% | 0.2% | 0.001kvarh | 0-999999.999kvarh |
Apparent Energy Primary | 0.5% | 0.2% | 0.1kVAh | 0-99999999.9kVAh |
Apparent Energy Secondary | 0.5% | 0.2% | 0.001kVAh | 0-999999.999kVAh |
Harmonics | 1.0% | 1.0% | 0.1% | 0.0%~100.0% 20.0%~100.0% (IIR/IIE/IIW) |
Phase Angle | 2.0% | 2.0% | 0.1° | 0.0°~359.9° |
Unbalance Factor | 2.0% | 2.0% | 0.1% | 0.0%~100.0% |
Running Time | 0.01h | 0~9999999.99h |
Current Inputs (Each Channel) | |
---|---|
Nominal Current | 5A /1A |
Metering Range | 0~10A AC |
Withstand | 20Arms continuous, 100Arms for 1 second, non-recurring |
Burden | 0.05VA (typical) @ 5Arms |
Pickup Current | 0.1% of nominal |
Accuracy | 0.2% full scale |
Voltage Inputs (Each Channel) | |
Nominal Full Scale | 400V AC L-N, 690V AC L-L (+20%) |
Withstand | 1500V AC continuous 2500V AC, 50/60Hz for 1 minute |
Input Impedance | 2Mohm per phase |
Metering Frequency | 45Hz~65Hz |
Pickup Voltage | 10Vac (30 Vac for Acuvim IIR/IIE/IIW) |
Accuracy | 0.2% full scale |
Energy Accuracy (Acuvim IIR/IIE/IIW) | |
Active | According to IEC 62053-22: Class 0.2s According to ANSI C12.20: Class 0.2s |
Reactive (according to IEC 62053-23) | Class 2 |
Harmonic Resolution | |
Metered Value | Acuvim II: 31st harmonic Acuvim IIR/IIE/IIW: 63rd harmonic |
Control Power | |
Universal | AC or DC |
Operating Range | 100~415V AC, 50/60Hz 100~300V DC |
Burden | 5W |
Frequency | 50/60Hz |
Withstand | 3250V AC, 50/60Hz for 1 minute Installation Category III (Distribution) |
Low Voltage DC Control Power (Optional) | |
Operating Range | 20~60V DC |
Burden | 5W |
Rs-485 (standard)
MODBUS® RTU Protocol, 2-wire connection
1200~38400 baud rate
The second Rs-485 Port (Optional)
MODBUS® RTU Protocol, 2-wire connection
4800~38400 baud rate
Ethernet (Optional)
10M/100M BaseT
MODBUS® TCP/IP Protocol
Data Browsing through HTTP
Sending e-mail automatically
PROFI-BUs (Optional)
PROFIBUS-DP/V0 Protoco
Work as PROFIBUS slave, baud rate adaptive, up to 12M
Typical input bytes: 32, typical output bytes: 32
PROFIBUS standard according to EN 50170 vol.2
Category | Item | Parameters | Acuvim II | Acuvim IIR | Acuvim IIE | |
Metering | Real Time Metering | Phase Voltage | V1, V2, V3, Vlnavg | |||
Metering | Real Time Metering | Line Voltage | V12, V23, V31, Vllavg | |||
Metering | Real Time Metering | Current | I1, I2, I3, In, Iavg | |||
Metering | Real Time Metering | Power | P1, P2, P3, Psum | |||
Metering | Real Time Metering | Reactive Power | Q1, Q2, Q3, Qsum | |||
Metering | Real Time Metering | Apparent Power | S1, S2, S3, Ssum | |||
Metering | Real Time Metering | Power Factor | PF1, PF2, PF3, PF | |||
Metering | Real Time Metering | Frequency | F | |||
Metering | Real Time Metering | Load Features | Load Features | |||
Metering | Real Time Metering | Four Quadrant Powers | Four Quadrant Powers | |||
Metering | Energy & Demand | Energy | Ep_imp, Ep_exp, Ep_total, Ep_net | |||
Metering | Energy & Demand | Reactive Energy | Eq_imp, Eq_exp, Eq_total, Eq_net | |||
Metering | Energy & Demand | Apparent Energy | Es | |||
Metering | Energy & Demand | Demand | Dmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3 | |||
TOU | Time of Use | Energy/max demand | TOU, 4 Tariffs, 12 Seasons, 14 Schedules | |||
TOU | Daylight Savings Time | Two formats adjust | Month/Day/Hour/Minute Month/Week/First few weeks/Hour/Minute |
|||
Monitoring | Waveform Capture | voltage and current Waveform | Trigger, Manual, DI change, Sag/Dips, Swell, Over Current | |||
Monitoring | Power Quality | Voltage Unbalance Factor | U_unbl | |||
Monitoring | Power Quality | Current Unbalance Factor | I_unbl | |||
Monitoring | Power Quality | Voltage THD | THD_V1,THD_V2,THD_V3, THD_Vavg | |||
Monitoring | Power Quality | Current THD | THD_I1, THD_I2, THD_I, THD_Iavg | |||
Monitoring | Power Quality | Individual Harmonics | Harmonics 2nd to 63rd (31st for Acuvim II) | |||
Monitoring | Power Quality | Voltage Crest Factor | Crest Factor | |||
Monitoring | Power Quality | TIF | THFF | |||
Monitoring | Power Quality | Current K factor | K Factor | |||
Monitoring | Statistics | MAX with Time Stamp MIN with Time Stamp |
Each phase of V & l; Total of P, Q, S, PF & F; Demad of P,Q & S; Each phase THD of V & I; Unbalnce factor of V & I |
|||
Others | Alarm | Over/Under Limit Alarm | V, I, P, Q, S, PF, V_THD & I_THD each phase and total or average; Unbalance factor of V & I; load type; Analog Input of each channel | |||
Others | Power Quality Event logging | SAG/DIPS,SWELL | Voltage | |||
Others | Data Logging | Data Logging 1 Data Logging 2 Data Logging 3 |
F, V1/2/3/lnavg, V12/23/13/lavg, I1/2/3/n/avg, P1/2/3/sum,Q1/2/3/sum, S1/2/3/sum, PF1/2/3, PF, U_unbl, I_unbl, LoadType, Ep_imp, Ep_exp, Ep_total, Ep_net, Eq_imp, Eq_exp, Eq_total, Eq_net, Es, THD_V1/2/3/avg, THD_I1/2/3/avg, Harmonics2nd to 63rd, Crest Factor, THFF, K Factor, sequence and phaseangles, DI counter, AI, AO, Dmd P/Q/S, Dmd I1/2/3 | |||
Others | Onboard memory size | Memory | Bytes | - | 4MB | 4MB |
Others | Communication | RS485 Port, Half Duplex,Optical Isolated | Modbus®-RTU Protocol | |||
Others | Time | Real Time Clock | Year, Month, Date, Hour, Minute, Second | |||
Option Module | I/O Option | Switch Status (DI) | Digital Input (Wet) | Option | Option | Option |
Option Module | I/O Option | Power Supply for DI | 24 Vdc | Option | Option | Option |
Option Module | I/O Option | Relay Output (RO) | NO, Form A | Option | Option | Option |
Option Module | I/O Option | Digital Output (DO) | Photo-MOS | Option | Option | Option |
Option Module | I/O Option | Pulse Output (PO) | By using DO | Option | Option | Option |
Option Module | I/O Option | Analog Input (AI) | 0(4)~20mA, 0(1)~5V | Option | Option | Option |
Option Module | I/O Option | Analog Output (AO) | 0(4)~20mA, 0(1)~5V | Option | Option | Option |
Option Module | Communication | Ethernet | 10M/100M, Modbus-TCP, HTTP Webpage, Email | Option | Option | Option |
Option Module | Communication | Profibus-DP | Profibus-DP/V0 | Option | Option | Option |
Option Module | Communication | RS485 Module | Additional Modbus RTU | Option | Option | Option |
As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.
Click on a category to view a selection of compatible accessories with the Accuenergy Acuvim II Series of Intelligent Power/Energy Meters.