Accuenergy Acuvim IIR-M-5A-P1V3 Revenue Grade Power/Energy Meter, DIN rail, 5 A/1 A input, 415 Vac/300 Vdc

Model: Acuvim IIR-M-5A-P1V3 | Order No: ACUVIM-IIR-M-5A-P1V3

Accuenergy Acuvim IIR-M-5A-P1V3 Revenue Grade Power/Energy Meter, DIN rail, 5 A/1 A input, 415 Vac/300 Vdc

Model: Acuvim IIR-M-5A-P1V3 | Order No: ACUVIM-IIR-M-5A-P1V3

Revenue grade power meter with data logging capabilites for single and three phase circuits features DIN rail mount transducer without display, field selectable 5 A or 1 A input for current transformers and wide range AC power supply input.

Revenue grade power meter with data logging capabilites for single and three phase circuits features DIN rail mount transducer without display, field selectable 5 A or 1 A input for current transformers and wide range AC power supply input.

Sale Price $547.40 USD
Regular Price $595.00 USD
Availability 1 in Stock
Quantity
Top selling accessories with the Acuvim II series

Clear selected options

Top selling accessories with the Acuvim II series

Clear selected options


The Acuvim IIR

The Acuvim IIR is a revenue grade multifunction power meter with data logging capabilities for single and three phase circuits. The Acuvim IIR meter features Modbus RS485 communication standard and can be upgraded to include Modbus TCP Ethernet, BACnet, Profibus, and a variety of other communication protocols and I/O expansions for added versatility.

Revenue Grade Power Metering

The Acuvim IIR features 0.2% accuracy with ANSI C12.20 standard for revenue grade meters and maintains a historical record of data for users to remotely monitor trends, analysis and reports with the capability to set threshold alarms in such applications as tenant and facility metering. Acuvim IIR offers 3 assignable historical logs where the majority of the metering parameters can be recorded. The onboard memory is up to 8 MB and each log size is adjustable. A real time clock allows for any logged events to be accurately time stamped. With AXM-WEB2, memory size expands to industry-leading 8GB memory with 1-second interval data logging.


About the Acuvim II Series

The Acuvim II series are high-end multifunction power and energy meters manufactured by Accuenergy. They are the ideal choice for the monitoring and controlling of power distribution systems.

The Acuvim II series may be used as data gathering devices for intelligent power distribution systems or plant automation systems. All monitored data is available via a digital RS485 communication port running Modbus RTU protocol. Ethernet and Profibus DP communication are also options.

With its flexible, modular I/O and communication options, the Acuvim II series is the most versatile and cost-effective metering solution on the market.

Those looking for Time of Use (TOU) features should check out the Acuvim-IIE instead.


Key Features

Metering

  • Voltage V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg
  • Current I1, I2, I3, In, Iavg
  • Power P1, P2, P3, Psum
  • Reactive Power Q1, Q2, Q3, Qsum
  • Apparent Power S1, S2, S3, Ssum
  • Frequency F
  • Power Factor PF1, PF2, PF3, PF
  • Energy Ep_imp, Ep_exp, Ep_total, Ep_net
  • Reactive Energy Eq_imp, Eq_exp, Eq_total, Eq_net
  • Apparent Energy Es
  • Demand Dmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3
  • Load Features
  • Four Quadrant Powers

Monitoring

  • Power Quality
  • Voltage Harmonics 2nd to 63rd and THD
  • Current Harmonics 2nd to 63rd and THD
  • Voltage Crest Factor
  • THFF (TIF)
  • Current K Factor
  • Voltage Unbalance Factor U_unbl
  • Current Unbalance Factor I_unbl
  • Max/Min Statistics with Time Stamps
  • Sampling rate 128 samples per cycle

Alarms

Limits can be set for up to 16 indicated parameters and can be set with a specified time interval. If any input of the indicated parameters is over or under its setting limit and persists over the specified time interval, the event will be recorded with time stamps and trigger the Alarm DO output. The 16 indicated parameters can be selected from any of the 51 parameters available.

Data Logging

Acuvim IIR offers 3 assignable historical logs where the majority of the metering parameters can be recorded. The onboard memory is up to 8 MB and each log size is adjustable. A real time clock allows for any logged events to be accurately time stamped.


Acuvim II Various Communication Options

Communications

Accuvim AXM-WEB Cross-Platform Ethernet Module for Acuvim II-Series Power Meters
Bring the Acuvim II data online with this Module, which features a fast 100ms response rate.

Acuvim AXM-NET Ethernet Module for Acuvim II-Series Power Meters
Ethernet module for Acuvim II Series power meters. Includes built-in webserver, automated scheduled email reports, email alarms based on configurable thresholds.

Acuvim AXM-PROFI Profibus Module for Acuvim II-Series Power Meters
PROFI-BUS module for Acuvim II Series power meters.

Acuvim II Series is DIN Rail Mountable

Mounting & Display Options

The Acuvim II Series is available in two mounting options:

Standard with LCD Display

The standard model is ANSI C39.1 Standard Compliant with a small size 96x96 outline.

DIN Rail Mount (Remote LCD Display Optional)

The DIN Rail compatible units are DIN 43700 Standard Compliant. The Acuvim II series also offers an optional Remote LCD display.


Applications

  • Metering of distribution feeders, transformers, generators, capacitor banks and motors
  • Medium and low voltage systems
  • Commercial, industrial, utility
  • Power quality analysis
  • Data logging

Acuvim II Series Typical Wiring

Typical Wiring Setups for the Acuvim II

Acuvim IIR Specifications

  Accuracy
Acuvim-II
Accuracy
Acuvim-IIR/IIE/IIW
Resolution Range
Voltage 0.2% 0.2% 0.1V 20V~1000kV
Current 0.2% 0.2% 0.1mA 5mA~50000A
Power 0.5% 0.2% 1W -9999MW~9999MW
Reactive Power 0.5% 0.2% 1var 9999Mvar~9999Mvar
Apparent Power 0.5% 0.2% 1VA 0~9999MVA
Power Demand 0.5% 0.2% 1W -9999MW~9999MW
Reactive Power Demand 0.5% 0.2% 1var -9999Mvar~9999Mvar
Apparent Power Demand 0.5% 0.2% 0.2% 0~9999MVA
Power Factor 0.5% 0.2% 0.001 -1.000~1.000
Frequency 0.2% 0.2% 0.01Hz 45.00~65.00Hz
Energy Primary 0.5% 0.2% 0.1kWh 0-99999999.9kWh
Energy Secondary 0.5% 0.2% 0.001kWh 0-999999.999kWh
Reactive Energy Primary 0.5% 0.2% 0.1kvarh 0-99999999.9kvarh
Reactive Energy Secondary 0.5% 0.2% 0.001kvarh 0-999999.999kvarh
Apparent Energy Primary 0.5% 0.2% 0.1kVAh 0-99999999.9kVAh
Apparent Energy Secondary 0.5% 0.2% 0.001kVAh 0-999999.999kVAh
Harmonics 1.0% 1.0% 0.1% 0.0%~100.0%
20.0%~100.0% (IIR/IIE/IIW)
Phase Angle 2.0% 2.0% 0.1° 0.0°~359.9°
Unbalance Factor 2.0% 2.0% 0.1% 0.0%~100.0%
Running Time     0.01h 0~9999999.99h
Current Inputs (Each Channel)
Nominal Current 5A /1A
Metering Range 0~10A AC
Withstand 20Arms continuous,
100Arms for 1 second, non-recurring
Burden 0.05VA (typical) @ 5Arms
Pickup Current 0.1% of nominal
Accuracy 0.2% full scale
Voltage Inputs (Each Channel)
Nominal Full Scale 400V AC L-N, 690V AC L-L (+20%)
Withstand 1500V AC continuous
2500V AC, 50/60Hz for 1 minute
Input Impedance 2Mohm per phase
Metering Frequency 45Hz~65Hz
Pickup Voltage 10V AC (30V AC for Acuvim IIR/IIE/IIW)
Accuracy 0.2% full scale
Energy Accuracy (Acuvim IIR/IIE/IIW)
Active According to IEC 62053-22: Class 0.2s
According to ANSI C12.20: Class 0.2s
Reactive (according to IEC 62053-23) Class 2
Harmonic Resolution
Metered Value Acuvim II: 31st harmonic
Acuvim IIR/IIE/IIW: 63rd harmonic
Control Power
Universal AC or DC
Operating Range 100~415V AC, 50/60Hz
100~300V DC
Burden 5W
Frequency 50/60Hz
Withstand 3250V AC, 50/60Hz for 1 minute
Installation Category III (Distribution)
Low Voltage DC Control Power (Optional)
Operating Range 20~60V DC
Burden 5W

Communication

Rs-485 (standard)
MODBUS® RTU Protocol, 2-wire connection
1200~38400 baud rate

The second Rs-485 Port (Optional)
MODBUS® RTU Protocol, 2-wire connection
4800~38400 baud rate

Ethernet (Optional)
10M/100M BaseT
MODBUS® TCP/IP Protocol
Data Browsing through HTTP
Sending e-mail automatically

PROFI-BUs (Optional)
PROFIBUS-DP/V0 Protoco
Work as PROFIBUS slave, baud rate adaptive, up to 12M
Typical input bytes: 32, typical output bytes: 32
PROFIBUS standard according to EN 50170 vol.2

Click here for complete specifications on the Accuenergy Acuvim IIR-M-5A-P1V3

What's included with the Accuenergy Acuvim IIR-M-5A-P1V3

  • Accuenergy Acuvim IIR-M-5A-P1V3 Revenue Grade Power/Energy Meter, DIN rail, 5 A/1 A input, 415 Vac/300 Vdc

Acuvim II Series Comparison

Category Item Parameters Acuvim II Acuvim IIR Acuvim IIE Acuvim IIW
Metering Real Time Metering Phase Voltage V1, V2, V3, Vlnavg
Metering Real Time Metering Line Voltage V12, V23, V31, Vllavg
Metering Real Time Metering Current I1, I2, I3, In, Iavg
Metering Real Time Metering Power P1, P2, P3, Psum
Metering Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Metering Real Time Metering Apparent Power S1, S2, S3, Ssum
Metering Real Time Metering Power Factor PF1, PF2, PF3, PF
Metering Real Time Metering Frequency F
Metering Real Time Metering Load Features Load Features
Metering Real Time Metering Four Quadrant Powers Four Quadrant Powers
Metering Energy & Demand Energy Ep_imp, Ep_exp, Ep_total, Ep_net
Metering Energy & Demand Reactive Energy Eq_imp, Eq_exp, Eq_total, Eq_net
Metering Energy & Demand Apparent Energy Es
Metering Energy & Demand Demand Dmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3
TOU Time of Use Energy/max demand TOU, 4 Tariffs, 12 Seasons, 14 Schedules
TOU Daylight Savings Time Two formats adjust Month/Day/Hour/Minute
Month/Week/First few weeks/Hour/Minute
Monitoring Waveform Capture voltage and current Waveform Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Monitoring Power Quality Voltage Unbalance Factor U_unbl
Monitoring Power Quality Current Unbalance Factor I_unbl
Monitoring Power Quality Voltage THD THD_V1,THD_V2,THD_V3, THD_Vavg
Monitoring Power Quality Current THD THD_I1, THD_I2, THD_I, THD_Iavg
Monitoring Power Quality Individual Harmonics Harmonics 2nd to 63rd (31st for Acuvim II)
Monitoring Power Quality Voltage Crest Factor Crest Factor
Monitoring Power Quality TIF THFF
Monitoring Power Quality Current K factor K Factor
Monitoring Statistics MAX with Time Stamp
MIN with Time Stamp
Each phase of V & l; Total of P, Q, S, PF & F; Demad of P,Q & S;
Each phase THD of V & I; Unbalnce factor of V & I
Others Alarm Over/Under Limit Alarm V, I, P, Q, S, PF, V_THD & I_THD each phase and total or average; Unbalance factor of V & I; load type; Analog Input of each channel
Others Power Quality Event logging SAG/DIPS,SWELL Voltage
Others Data Logging Data Logging 1
Data Logging 2
Data Logging 3
F, V1/2/3/lnavg, V12/23/13/lavg, I1/2/3/n/avg, P1/2/3/sum,Q1/2/3/sum, S1/2/3/sum, PF1/2/3, PF, U_unbl, I_unbl, LoadType, Ep_imp, Ep_exp, Ep_total, Ep_net, Eq_imp, Eq_exp, Eq_total, Eq_net, Es, THD_V1/2/3/avg, THD_I1/2/3/avg, Harmonics2nd to 63rd, Crest Factor, THFF, K Factor, sequence and phaseangles, DI counter, AI, AO, Dmd P/Q/S, Dmd I1/2/3
Others Onboard memory size Memory Bytes - 4MB 4MB 8MB
Others Communication RS485 Port, Half Duplex,Optical Isolated Modbus®-RTU Protocol
Others Time Real Time Clock Year, Month, Date, Hour, Minute, Second
Option Module I/O Option Switch Status (DI) Digital Input (Wet) Option Option Option Option
Option Module I/O Option Power Supply for DI 24 Vdc Option Option Option Option
Option Module I/O Option Relay Output (RO) NO, Form A Option Option Option Option
Option Module I/O Option Digital Output (DO) Photo-MOS Option Option Option Option
Option Module I/O Option Pulse Output (PO) By using DO Option Option Option Option
Option Module I/O Option Analog Input (AI) 0(4)~20mA, 0(1)~5V Option Option Option Option
Option Module I/O Option Analog Output (AO) 0(4)~20mA, 0(1)~5V Option Option Option Option
Option Module Communication Ethernet 10M/100M, Modbus-TCP, HTTP Webpage, Email Option Option Option Option
Option Module Communication Profibus-DP Profibus-DP/V0 Option Option Option Option
Option Module Communication RS485 Module Additional Modbus RTU Option Option Option Option

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration of Accuenergy meters
  • Remote and real time monitoring of all meter parameters
  • Dozens of meters can be connected to a single PC
  • Multiple meters can be displayed and tiled in one window
  • Real time data logging
  • Logging of data from the I/O modules (pulses from water, gas, flow, etc)
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats)
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored

Click on a category to view a selection of compatible accessories with the Accuenergy Acuvim IIR-M-5A-P1V3 Revenue Grade Power/Energy Meter, DIN rail, 5 A/1 A input, 415 Vac/300 Vdc.

Acuvim AXM-IO1 Digital/Analog I/O Module 6DI, 1 Power Supply for DI, 2RO AXM-IO1
This plug-in I/O module integrates data to/from other devices and is field expandable. It provides added functions and increased versatility for any of the Avuvim II Series. These increased functions can be enabled by simply snapping on the module to the back of either meter and can work in conjunction with two other extension modules (cannot be paired with the same module). This module features 6 Digital Inputs, 24V DC Power for Digital Inputs, and 2x Relay Outputs.




Acuvim AXM-IO2 Digital/Analog I/O Module 4DI, 2DO, 2AO AXM-IO2
This plug-in I/O module integrates data to/from other devices and is field expandable. It provides added functions and increased versatility for any of the Avuvim II Series. These increased functions can be enabled by simply snapping on the module to the back of either meter and can work in conjunction with two other extension modules (cannot be paired with the same module). This module features 4 Digital Inputs, 2 Digital Outputs, and 2 Analog Outputs of 4 to 10mA.




Acuvim AXM-IO3 Digital/Analog I/O Module 4DI, 2RO, 2AI AXM-IO3
This plug-in I/O module integrates data to/from other devices and is field expandable. It provides added functions and increased versatility for any of the Avuvim II Series. These increased functions can be enabled by simply snapping on the module to the back of either meter and can work in conjunction with two other extension modules (cannot be paired with the same module). This module features 4 Digital Inputs, 2 Relay Outputs, and 2 Analog Inputs of 4 to 10mA.





Accuenergy AXM-WEB Ethernet Module for Acuvim II AXM-WEB
Provides an Ethernet connection to the Acuvim II Series power meters via Modbus-TCP/IP, HTTP Post, HTTPS Post, FTP, SMTP for e-mail, and SNTP time synchronization. Features 4GB onboard memory with 15-second interval data logging capabilities, and industry-leading 100ms response rate via ModbusTCP/IP protocol.




Ask a question about Accuenergy Acuvim IIR-M-5A-P1V3 Revenue Grade Power/Energy Meter, DIN rail, 5 A/1 A input, 415 Vac/300 Vdc

Customer Reviews for the Accuenergy Acuvim IIR-M-5A-P1V3

The Acuvim IIR

The Acuvim IIR is a revenue grade multifunction power meter with data logging capabilities for single and three phase circuits. The Acuvim IIR meter features Modbus RS485 communication standard and can be upgraded to include Modbus TCP Ethernet, BACnet, Profibus, and a variety of other communication protocols and I/O expansions for added versatility.

Revenue Grade Power Metering

The Acuvim IIR features 0.2% accuracy with ANSI C12.20 standard for revenue grade meters and maintains a historical record of data for users to remotely monitor trends, analysis and reports with the capability to set threshold alarms in such applications as tenant and facility metering. Acuvim IIR offers 3 assignable historical logs where the majority of the metering parameters can be recorded. The onboard memory is up to 8 MB and each log size is adjustable. A real time clock allows for any logged events to be accurately time stamped. With AXM-WEB2, memory size expands to industry-leading 8GB memory with 1-second interval data logging.


About the Acuvim II Series

The Acuvim II series are high-end multifunction power and energy meters manufactured by Accuenergy. They are the ideal choice for the monitoring and controlling of power distribution systems.

The Acuvim II series may be used as data gathering devices for intelligent power distribution systems or plant automation systems. All monitored data is available via a digital RS485 communication port running Modbus RTU protocol. Ethernet and Profibus DP communication are also options.

With its flexible, modular I/O and communication options, the Acuvim II series is the most versatile and cost-effective metering solution on the market.

Those looking for Time of Use (TOU) features should check out the Acuvim-IIE instead.


Key Features

Metering

  • Voltage V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg
  • Current I1, I2, I3, In, Iavg
  • Power P1, P2, P3, Psum
  • Reactive Power Q1, Q2, Q3, Qsum
  • Apparent Power S1, S2, S3, Ssum
  • Frequency F
  • Power Factor PF1, PF2, PF3, PF
  • Energy Ep_imp, Ep_exp, Ep_total, Ep_net
  • Reactive Energy Eq_imp, Eq_exp, Eq_total, Eq_net
  • Apparent Energy Es
  • Demand Dmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3
  • Load Features
  • Four Quadrant Powers

Monitoring

  • Power Quality
  • Voltage Harmonics 2nd to 63rd and THD
  • Current Harmonics 2nd to 63rd and THD
  • Voltage Crest Factor
  • THFF (TIF)
  • Current K Factor
  • Voltage Unbalance Factor U_unbl
  • Current Unbalance Factor I_unbl
  • Max/Min Statistics with Time Stamps
  • Sampling rate 128 samples per cycle

Alarms

Limits can be set for up to 16 indicated parameters and can be set with a specified time interval. If any input of the indicated parameters is over or under its setting limit and persists over the specified time interval, the event will be recorded with time stamps and trigger the Alarm DO output. The 16 indicated parameters can be selected from any of the 51 parameters available.

Data Logging

Acuvim IIR offers 3 assignable historical logs where the majority of the metering parameters can be recorded. The onboard memory is up to 8 MB and each log size is adjustable. A real time clock allows for any logged events to be accurately time stamped.


Acuvim II Various Communication Options

Communications

Accuvim AXM-WEB Cross-Platform Ethernet Module for Acuvim II-Series Power Meters
Bring the Acuvim II data online with this Module, which features a fast 100ms response rate.

Acuvim AXM-NET Ethernet Module for Acuvim II-Series Power Meters
Ethernet module for Acuvim II Series power meters. Includes built-in webserver, automated scheduled email reports, email alarms based on configurable thresholds.

Acuvim AXM-PROFI Profibus Module for Acuvim II-Series Power Meters
PROFI-BUS module for Acuvim II Series power meters.

Acuvim II Series is DIN Rail Mountable

Mounting & Display Options

The Acuvim II Series is available in two mounting options:

Standard with LCD Display

The standard model is ANSI C39.1 Standard Compliant with a small size 96x96 outline.

DIN Rail Mount (Remote LCD Display Optional)

The DIN Rail compatible units are DIN 43700 Standard Compliant. The Acuvim II series also offers an optional Remote LCD display.


Applications

  • Metering of distribution feeders, transformers, generators, capacitor banks and motors
  • Medium and low voltage systems
  • Commercial, industrial, utility
  • Power quality analysis
  • Data logging

Acuvim II Series Typical Wiring

Typical Wiring Setups for the Acuvim II

Acuvim IIR Specifications

  Accuracy
Acuvim-II
Accuracy
Acuvim-IIR/IIE/IIW
Resolution Range
Voltage 0.2% 0.2% 0.1V 20V~1000kV
Current 0.2% 0.2% 0.1mA 5mA~50000A
Power 0.5% 0.2% 1W -9999MW~9999MW
Reactive Power 0.5% 0.2% 1var 9999Mvar~9999Mvar
Apparent Power 0.5% 0.2% 1VA 0~9999MVA
Power Demand 0.5% 0.2% 1W -9999MW~9999MW
Reactive Power Demand 0.5% 0.2% 1var -9999Mvar~9999Mvar
Apparent Power Demand 0.5% 0.2% 0.2% 0~9999MVA
Power Factor 0.5% 0.2% 0.001 -1.000~1.000
Frequency 0.2% 0.2% 0.01Hz 45.00~65.00Hz
Energy Primary 0.5% 0.2% 0.1kWh 0-99999999.9kWh
Energy Secondary 0.5% 0.2% 0.001kWh 0-999999.999kWh
Reactive Energy Primary 0.5% 0.2% 0.1kvarh 0-99999999.9kvarh
Reactive Energy Secondary 0.5% 0.2% 0.001kvarh 0-999999.999kvarh
Apparent Energy Primary 0.5% 0.2% 0.1kVAh 0-99999999.9kVAh
Apparent Energy Secondary 0.5% 0.2% 0.001kVAh 0-999999.999kVAh
Harmonics 1.0% 1.0% 0.1% 0.0%~100.0%
20.0%~100.0% (IIR/IIE/IIW)
Phase Angle 2.0% 2.0% 0.1° 0.0°~359.9°
Unbalance Factor 2.0% 2.0% 0.1% 0.0%~100.0%
Running Time     0.01h 0~9999999.99h
Current Inputs (Each Channel)
Nominal Current 5A /1A
Metering Range 0~10A AC
Withstand 20Arms continuous,
100Arms for 1 second, non-recurring
Burden 0.05VA (typical) @ 5Arms
Pickup Current 0.1% of nominal
Accuracy 0.2% full scale
Voltage Inputs (Each Channel)
Nominal Full Scale 400V AC L-N, 690V AC L-L (+20%)
Withstand 1500V AC continuous
2500V AC, 50/60Hz for 1 minute
Input Impedance 2Mohm per phase
Metering Frequency 45Hz~65Hz
Pickup Voltage 10V AC (30V AC for Acuvim IIR/IIE/IIW)
Accuracy 0.2% full scale
Energy Accuracy (Acuvim IIR/IIE/IIW)
Active According to IEC 62053-22: Class 0.2s
According to ANSI C12.20: Class 0.2s
Reactive (according to IEC 62053-23) Class 2
Harmonic Resolution
Metered Value Acuvim II: 31st harmonic
Acuvim IIR/IIE/IIW: 63rd harmonic
Control Power
Universal AC or DC
Operating Range 100~415V AC, 50/60Hz
100~300V DC
Burden 5W
Frequency 50/60Hz
Withstand 3250V AC, 50/60Hz for 1 minute
Installation Category III (Distribution)
Low Voltage DC Control Power (Optional)
Operating Range 20~60V DC
Burden 5W

Communication

Rs-485 (standard)
MODBUS® RTU Protocol, 2-wire connection
1200~38400 baud rate

The second Rs-485 Port (Optional)
MODBUS® RTU Protocol, 2-wire connection
4800~38400 baud rate

Ethernet (Optional)
10M/100M BaseT
MODBUS® TCP/IP Protocol
Data Browsing through HTTP
Sending e-mail automatically

PROFI-BUs (Optional)
PROFIBUS-DP/V0 Protoco
Work as PROFIBUS slave, baud rate adaptive, up to 12M
Typical input bytes: 32, typical output bytes: 32
PROFIBUS standard according to EN 50170 vol.2

Click here for complete specifications on the Accuenergy Acuvim IIR-M-5A-P1V3

What's included with the Accuenergy Acuvim IIR-M-5A-P1V3

  • Accuenergy Acuvim IIR-M-5A-P1V3 Revenue Grade Power/Energy Meter, DIN rail, 5 A/1 A input, 415 Vac/300 Vdc

Acuvim II Series Comparison

Category Item Parameters Acuvim II Acuvim IIR Acuvim IIE Acuvim IIW
Metering Real Time Metering Phase Voltage V1, V2, V3, Vlnavg
Metering Real Time Metering Line Voltage V12, V23, V31, Vllavg
Metering Real Time Metering Current I1, I2, I3, In, Iavg
Metering Real Time Metering Power P1, P2, P3, Psum
Metering Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Metering Real Time Metering Apparent Power S1, S2, S3, Ssum
Metering Real Time Metering Power Factor PF1, PF2, PF3, PF
Metering Real Time Metering Frequency F
Metering Real Time Metering Load Features Load Features
Metering Real Time Metering Four Quadrant Powers Four Quadrant Powers
Metering Energy & Demand Energy Ep_imp, Ep_exp, Ep_total, Ep_net
Metering Energy & Demand Reactive Energy Eq_imp, Eq_exp, Eq_total, Eq_net
Metering Energy & Demand Apparent Energy Es
Metering Energy & Demand Demand Dmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3
TOU Time of Use Energy/max demand TOU, 4 Tariffs, 12 Seasons, 14 Schedules
TOU Daylight Savings Time Two formats adjust Month/Day/Hour/Minute
Month/Week/First few weeks/Hour/Minute
Monitoring Waveform Capture voltage and current Waveform Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Monitoring Power Quality Voltage Unbalance Factor U_unbl
Monitoring Power Quality Current Unbalance Factor I_unbl
Monitoring Power Quality Voltage THD THD_V1,THD_V2,THD_V3, THD_Vavg
Monitoring Power Quality Current THD THD_I1, THD_I2, THD_I, THD_Iavg
Monitoring Power Quality Individual Harmonics Harmonics 2nd to 63rd (31st for Acuvim II)
Monitoring Power Quality Voltage Crest Factor Crest Factor
Monitoring Power Quality TIF THFF
Monitoring Power Quality Current K factor K Factor
Monitoring Statistics MAX with Time Stamp
MIN with Time Stamp
Each phase of V & l; Total of P, Q, S, PF & F; Demad of P,Q & S;
Each phase THD of V & I; Unbalnce factor of V & I
Others Alarm Over/Under Limit Alarm V, I, P, Q, S, PF, V_THD & I_THD each phase and total or average; Unbalance factor of V & I; load type; Analog Input of each channel
Others Power Quality Event logging SAG/DIPS,SWELL Voltage
Others Data Logging Data Logging 1
Data Logging 2
Data Logging 3
F, V1/2/3/lnavg, V12/23/13/lavg, I1/2/3/n/avg, P1/2/3/sum,Q1/2/3/sum, S1/2/3/sum, PF1/2/3, PF, U_unbl, I_unbl, LoadType, Ep_imp, Ep_exp, Ep_total, Ep_net, Eq_imp, Eq_exp, Eq_total, Eq_net, Es, THD_V1/2/3/avg, THD_I1/2/3/avg, Harmonics2nd to 63rd, Crest Factor, THFF, K Factor, sequence and phaseangles, DI counter, AI, AO, Dmd P/Q/S, Dmd I1/2/3
Others Onboard memory size Memory Bytes - 4MB 4MB 8MB
Others Communication RS485 Port, Half Duplex,Optical Isolated Modbus®-RTU Protocol
Others Time Real Time Clock Year, Month, Date, Hour, Minute, Second
Option Module I/O Option Switch Status (DI) Digital Input (Wet) Option Option Option Option
Option Module I/O Option Power Supply for DI 24 Vdc Option Option Option Option
Option Module I/O Option Relay Output (RO) NO, Form A Option Option Option Option
Option Module I/O Option Digital Output (DO) Photo-MOS Option Option Option Option
Option Module I/O Option Pulse Output (PO) By using DO Option Option Option Option
Option Module I/O Option Analog Input (AI) 0(4)~20mA, 0(1)~5V Option Option Option Option
Option Module I/O Option Analog Output (AO) 0(4)~20mA, 0(1)~5V Option Option Option Option
Option Module Communication Ethernet 10M/100M, Modbus-TCP, HTTP Webpage, Email Option Option Option Option
Option Module Communication Profibus-DP Profibus-DP/V0 Option Option Option Option
Option Module Communication RS485 Module Additional Modbus RTU Option Option Option Option

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration of Accuenergy meters
  • Remote and real time monitoring of all meter parameters
  • Dozens of meters can be connected to a single PC
  • Multiple meters can be displayed and tiled in one window
  • Real time data logging
  • Logging of data from the I/O modules (pulses from water, gas, flow, etc)
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats)
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored

Click on a category to view a selection of compatible accessories with the Accuenergy Acuvim IIR-M-5A-P1V3 Revenue Grade Power/Energy Meter, DIN rail, 5 A/1 A input, 415 Vac/300 Vdc.

Acuvim AXM-IO1 Digital/Analog I/O Module 6DI, 1 Power Supply for DI, 2RO AXM-IO1
This plug-in I/O module integrates data to/from other devices and is field expandable. It provides added functions and increased versatility for any of the Avuvim II Series. These increased functions can be enabled by simply snapping on the module to the back of either meter and can work in conjunction with two other extension modules (cannot be paired with the same module). This module features 6 Digital Inputs, 24V DC Power for Digital Inputs, and 2x Relay Outputs.




Acuvim AXM-IO2 Digital/Analog I/O Module 4DI, 2DO, 2AO AXM-IO2
This plug-in I/O module integrates data to/from other devices and is field expandable. It provides added functions and increased versatility for any of the Avuvim II Series. These increased functions can be enabled by simply snapping on the module to the back of either meter and can work in conjunction with two other extension modules (cannot be paired with the same module). This module features 4 Digital Inputs, 2 Digital Outputs, and 2 Analog Outputs of 4 to 10mA.




Acuvim AXM-IO3 Digital/Analog I/O Module 4DI, 2RO, 2AI AXM-IO3
This plug-in I/O module integrates data to/from other devices and is field expandable. It provides added functions and increased versatility for any of the Avuvim II Series. These increased functions can be enabled by simply snapping on the module to the back of either meter and can work in conjunction with two other extension modules (cannot be paired with the same module). This module features 4 Digital Inputs, 2 Relay Outputs, and 2 Analog Inputs of 4 to 10mA.





Accuenergy AXM-WEB Ethernet Module for Acuvim II AXM-WEB
Provides an Ethernet connection to the Acuvim II Series power meters via Modbus-TCP/IP, HTTP Post, HTTPS Post, FTP, SMTP for e-mail, and SNTP time synchronization. Features 4GB onboard memory with 15-second interval data logging capabilities, and industry-leading 100ms response rate via ModbusTCP/IP protocol.




Ask a question about Accuenergy Acuvim IIR-M-5A-P1V3 Revenue Grade Power/Energy Meter, DIN rail, 5 A/1 A input, 415 Vac/300 Vdc

Customer Reviews for the Accuenergy Acuvim IIR-M-5A-P1V3

More Accuenergy Products

Calibration Lab