Combines the capabilities of a safety-rated digital multimeter and mA loop calibrator into one tool, this process meter is ideal for troubleshooting and calibrating current loop applications due to its ability to measure, source, and simulate mA. Additionally, it is Fluke Connect compatible when paired with the FC connector.
Combines the capabilities of a safety-rated digital multimeter and mA loop calibrator into one tool, this process meter is ideal for troubleshooting and calibrating current loop applications due to its ability to measure, source, and simulate mA. Additionally, it is Fluke Connect compatible when paired with the FC connector.
Features
Applications
V DC | |
Range and Resolution | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
Best Accuracy (% of Reading + LSD) | 0.1% + 1 |
V AC (True RMS) | |
Range and Resolution | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
Best Accuracy (% of Reading + LSD) | 0.7% + 2 |
mA DC | |
Range and Resolution | 30.000 mA |
Best Accuracy (% of Reading + LSD) | 0.05% + 2 |
mA DC | |
Range and Resolution | 30.000 mA |
Best Accuracy (% of Reading + LSD) | 0.05% + 2 |
A DC | |
Range and Resolution | 1.000 A (0.440 A continuous) |
Best Accuracy (% of Reading + LSD) | 0.2% + 2 |
A AC | |
Range and Resolution | 1.000 A (0.440 A continuous) |
Best Accuracy (% of Reading + LSD) | 1% + 2 |
Resistance | |
Range and Resolution | 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M |
Best Accuracy (% of Reading + LSD) | 0.2% + 1 |
Frequency (0.5 Hz to 20 kHz) | |
Range and Resolution | 199.99 Hz, 1999.9 Hz, 19.999 kHz |
Best Accuracy (% of Reading + LSD) | 0.005% + 1 |
Diode Test | |
Range and Resolution | 2.000 V (shows diode voltage drop) |
Best Accuracy (% of Reading + LSD) | 2% + 1 |
Continuity | |
Range and Resolution | Beeps for resistance <approx. 100 Ω |
DC Current Output (Internal Battery Operation) | |
Range and Resolution | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA |
Drive Capability | 24 V compliance or, 1,200 ohms, at 20 mA |
Accuracy (% of Span) | 0.05% |
DC Current Simulate (Ext. 15 to 48 V Loop Supply) | |
Range and Resolution | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA |
Drive Capability | 1000 ohms, at 20 mA |
Accuracy (% of Span) | 0.05% |
Current Adjustment Modes | |
Manual | Coarse, Fine, 25% and 100% step |
Automatic | Slow Ramp, Fast Ramp, 25% step |
General Specifications | |
Maximum Voltage Applied Between any Jack and Earth Ground | 1000 V RMS |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Operating Temperature | -4 to 131°F (-20 to 55°C) |
Temperature Coefficient | 0.05 x (specified accuracy) per °C (for temperatures <18°C or >28°C) |
Relative Humidity | 95% up to 86°F (30°C) 75% up to 104°F (40°C) 45% up to 122°F (50°C) 35% up to 131°F (55°C) |
Vibration | Random, 2 g, 5 to 500 Hz |
Shock | 3.3' (1 m) drop test |
Battery | 4 x AA Alkaline batteries |
Battery Life | 140 hours typical (measurement), 10 hours typical (sourcing 12 mA) |
Safety | IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000 V |
Dimensions | 1.97 x 3.94 x 8" (50 x 100 x 203 mm) |
Weight | 1.3 lbs (600 g) |
Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.
Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.
Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Click on a category to view a selection of compatible accessories with the Fluke 787B ProcessMeter, 1000 V.
V DC | |
Range and Resolution | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
Best Accuracy (% of Reading + LSD) | 0.1% + 1 |
V AC (True RMS) | |
Range and Resolution | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
Best Accuracy (% of Reading + LSD) | 0.7% + 2 |
mA DC | |
Range and Resolution | 30.000 mA |
Best Accuracy (% of Reading + LSD) | 0.05% + 2 |
mA DC | |
Range and Resolution | 30.000 mA |
Best Accuracy (% of Reading + LSD) | 0.05% + 2 |
A DC | |
Range and Resolution | 1.000 A (0.440 A continuous) |
Best Accuracy (% of Reading + LSD) | 0.2% + 2 |
A AC | |
Range and Resolution | 1.000 A (0.440 A continuous) |
Best Accuracy (% of Reading + LSD) | 1% + 2 |
Resistance | |
Range and Resolution | 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M |
Best Accuracy (% of Reading + LSD) | 0.2% + 1 |
Frequency (0.5 Hz to 20 kHz) | |
Range and Resolution | 199.99 Hz, 1999.9 Hz, 19.999 kHz |
Best Accuracy (% of Reading + LSD) | 0.005% + 1 |
Diode Test | |
Range and Resolution | 2.000 V (shows diode voltage drop) |
Best Accuracy (% of Reading + LSD) | 2% + 1 |
Continuity | |
Range and Resolution | Beeps for resistance <approx. 100 Ω |
DC Current Output (Internal Battery Operation) | |
Range and Resolution | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA |
Drive Capability | 24 V compliance or, 1,200 ohms, at 20 mA |
Accuracy (% of Span) | 0.05% |
DC Current Simulate (Ext. 15 to 48 V Loop Supply) | |
Range and Resolution | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA |
Drive Capability | 1000 ohms, at 20 mA |
Accuracy (% of Span) | 0.05% |
Current Adjustment Modes | |
Manual | Coarse, Fine, 25% and 100% step |
Automatic | Slow Ramp, Fast Ramp, 25% step |
General Specifications | |
Maximum Voltage Applied Between any Jack and Earth Ground | 1000 V RMS |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Operating Temperature | -4 to 131°F (-20 to 55°C) |
Temperature Coefficient | 0.05 x (specified accuracy) per °C (for temperatures <18°C or >28°C) |
Relative Humidity | 95% up to 86°F (30°C) 75% up to 104°F (40°C) 45% up to 122°F (50°C) 35% up to 131°F (55°C) |
Vibration | Random, 2 g, 5 to 500 Hz |
Shock | 3.3' (1 m) drop test |
Battery | 4 x AA Alkaline batteries |
Battery Life | 140 hours typical (measurement), 10 hours typical (sourcing 12 mA) |
Safety | IEC61010-1, Pollution Degree 2/IEC61010-2-033, CAT IV 600 V/CAT III 1000 V |
Dimensions | 1.97 x 3.94 x 8" (50 x 100 x 203 mm) |
Weight | 1.3 lbs (600 g) |
Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.
Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.
Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Click on a category to view a selection of compatible accessories with the Fluke 787B ProcessMeter, 1000 V.